  • Read this guide entirely before installation.
  • This document provides minimum requirements and recommendations for safe and successful installation of SoliTek PV modules and is necessary to retain compliance with IEC 61215, IEC 61730, and UL 61730 standards.
  • This guide provides basic information on JSC SoliTek Cells SOLID series photovoltaic modules, including their installation and safe handling.
  • All instructions should be read and understood before attempting installation. Contact your dealer or JSC SoliTek Cells for further information if needed.
  • This documentation refers to the PV modules themselves and is not a comprehensive installation manual for personnel not specifically trained in PV modules.
  • It serves as a general but strictly mandatory reference for the installer. Infringement or inaccurate observance of any clause in this documentation voids the warranty.
  • The installer must understand and follow all applicable local, state, and federal regulations and standards for building construction, electrical design, fire, and safety.
  • Check with local authorities for permitting requirements before installing or maintaining PV modules, and become familiar with mechanical and electrical requirements for photovoltaic systems.
  • 이 설명서의 지침을 따르지 않으면 시스템 구성 요소가 손상되거나, 인원이 위험해지거나, 재산이 손상되거나, 패널 보증이 무효화될 수 있습니다.
  • Rooftop PV systems should only be installed on dwellings formally analyzed for structural integrity and confirmed to be capable of handling the additional weighted load of PV system components (including PV modules) by a certified building specialist or engineer.

일반 요구 사항

  • 설치하기 전에 이 안내서를 완전히 읽으십시오.
  • 이 문서의 목적은 SoliTek PV 모듈의 안전하고 성공적인 설치를 위한 최소 요구 사항과 권장 사항을 제공하는 것입니다.
  • 이 문서에는 SoliTek PV 모듈이 IEC 61215, IEC 61730, UL 61730 표준을 준수하는 데 필요한 요구 사항도 포함되어 있습니다.
  • 이 안내서에는 JSC "SoliTek Cells" SOLID 시리즈 태양광 모듈, 설치 및 안전 취급에 관한 기본 정보가 포함되어 있습니다. 설치를 시도하기 전에 모든 지침을 읽고 이해해야 합니다. 질문이 있는 경우 자세한 내용은 대리점이나 JSC "SoliTek Cells"에 문의하십시오.
  • This documentation refers to the PV-modules themselves and is not meant to be a complete installation manual for personnel not specifically trained to PV-modules.
  • It serves as a general but strictly mandatory reference for the Installer.
  • 본 문서의 조항을 위반하거나 부정확하게 준수할 경우 보증이 무효화됩니다.
  • 설치자는 건물 구조, 전기 설계, 화재 및 안전에 대한 모든 해당 지역, 주 및 연방 규정과 표준을 이해하고 따라야 하며, PV 모듈을 설치 또는 유지 관리하기 전에 지역 당국과 확인하여 해당 허용 요구 사항을 결정해야 하며 다음을 수행해야 합니다. 광전지 시스템의 기계적, 전기적 요구 사항을 숙지하십시오.
  • 이 설명서의 지침을 따르지 않으면 시스템 구성 요소가 손상되거나, 인력이 위험해지거나, 재산이 손상되거나, 패널 보증이 무효화될 수 있습니다.
  • 옥상 PV 시스템은 공식적으로 구조적 무결성을 분석하고 인증된 건축 전문가 또는 엔지니어에 의해 PV 모듈을 포함한 PV 시스템 구성 요소의 추가 가중 부하를 처리할 수 있는 것으로 확인된 주택에만 설치해야 합니다.
  • For your safety, do not attempt to work on a rooftop until safety precautions have been identified and taken, including, without limitation fall protection measures, ladders or stairways, and personal protective equipment (PPE).
  • For your safety, do not install or handle PV modules under adverse conditions, including, without limitation strong or gusty winds, and wet or frosted roof surfaces.
  • 플랫 플레이트 PV 모듈 구조는 두 개의 유리 시트 내의 절연 재료 내에 캡슐화된 태양 전지의 적층 어셈블리로 구성됩니다.
  • 나중에 참조할 수 있도록 이 문서를 안전한 장소에 보관하십시오.
  • 모듈을 분해하려고 시도하지 말고 부착된 명판이나 부품을 제거하지 마십시오! 그렇게 하면 보증이 무효화됩니다.

취급 및 적용

손질

  • SoliTek PV modules must be transported in the supplied packaging only and kept in the packaging until they are ready to be installed.
  • Protect pallets against movement and exposure to damage during transportation. Secure pallets from falling over.
  • 팔레트 포장에 표시된 대로 쌓을 팔레트의 최대 높이를 초과하지 마십시오.
  • Store pallets in a cool and dry location until the PV modules are ready to be unpackaged.
  • SoliTek PV modules are heavy and should be handled with care. Never use the junction box or cables as a grip.
  • Do not exert mechanical stress on the cables.
  • Never step on PV modules or drop or place heavy objects on them.
  • Be careful when placing PV modules on hard surfaces and secure them from falling.
  • Broken glass can result in personal injury. PV modules with broken glass cannot be repaired and must not be used.
  • Broken or damaged PV modules must be handled carefully and disposed of properly.

애플리케이션

제한

  • SoliTek PV modules must be mounted on appropriate mounting structures positioned on suitable buildings, the ground, or other structures suitable for PV modules (e.g. carports, building facades or PV trackers).
  • PV modules must not be mounted on moving vehicles of any kind. Modules must not be installed in locations where they could be submerged in water.
  • Do not install modules above 2000 m (6561 ft) altitude above sea level
  • 인위적으로 집중된 빛이 SoliTek PV 모듈을 향해서는 안 됩니다.

추천사항

  • SoliTek은 비가 올 때 적절한 자체 청소가 가능하도록 최소 10도의 기울기 각도로 PV 모듈을 장착할 것을 권장합니다.
  • PV 모듈 또는 모듈의 부분적 또는 전체 차광은 시스템 성능을 크게 저하시킬 수 있습니다.
  • SoliTek은 PV 모듈에서 생산되는 에너지의 양을 늘리기 위해 일년 내내 그늘의 양을 최소화할 것을 권장합니다.
  • 높은 시스템 볼륨tages could be induced in the event of an indirect lightning strike, which could cause damage to PV system components.
  • The open area of wire loops should be minimized in order to reduce the risk of lightning-induced voltag전자 서지.
  • 더 나은 모듈 환기와 더 짧은 연결 케이블은 전기 에너지 생산을 증가시킵니다.

양면 모듈의 경우:

  • 더 많은 빛이 모듈 아래로 이동한 다음 반사될 수 있도록 지면에서 PV 패널 높이를 높이는 것이 좋습니다.
  • 흰색(높은 알베도 값)의 빛 반사 표면 위에 모듈을 설치하면 양면 게인이 크게 증가합니다.

전기 설치

안전

  • PV 모듈은 전류 및 볼륨을 생성할 수 있습니다.tage 어떤 강도의 빛에도 노출되었을 때. 전류는 광도가 높을수록 증가합니다. DC 권tag50볼트 이상의 e는 잠재적으로 치명적입니다. 조명 아래에서 작동하는 PV 시스템의 전기 회로에 접촉하면 치명적인 감전이 발생할 수 있습니다.
  • PV 모듈을 빛으로부터 완전히 제거하거나 전면을 불투명한 재료로 덮어서 전원을 차단합니다. 빛에 노출된 모듈로 작업할 때의 전기 장비 안전 규정에 대해. PV 모듈로 작업하는 동안 절연 도구를 사용하고 금속 장신구를 착용하지 마십시오.
  • 아크와 감전을 피하기 위해 부하가 걸린 상태에서 전기 연결을 분리하지 마십시오. 잘못된 연결은 아크와 감전을 초래할 수도 있습니다. 커넥터를 건조하고 깨끗하게 유지하고 제대로 작동하는지 확인하십시오. 전기 연결을 확보하기 위해 커넥터에 금속 물체를 넣거나 어떤 식으로든 개조하지 마십시오.
  • Do not touch or handle PV modules with broken glass unless the PV modules are first disconnected, and you are wearing proper PPE. Avoid handling PV modules when they are wet unless cleaning the PV modules as directed in this manual. Never touch electrical and wet connections without protecting yourself with insulated gloves.
  • The modules are qualified for Class II protection against electrical shock, in accordance with clause 4 of IEC 61730-1:2016, which can be used in systems operating at > 50 V DC or >240 W, where general contact access is anticipated and modules qualified for safety through UL 61730 within this application class are considered to meet the requirements of Safety Class II.
  • 태양광 발전 시스템을 설치하려면 전문 기술과 지식이 필요합니다. 자격을 갖추고 특별히 교육을 받은 직원만 수행해야 합니다. 설치자는 감전 위험을 포함한 모든 부상 위험을 감수합니다.
  • 태양광 시스템용으로 특별히 설계된 장비, 커넥터, 배선 및 장착 하드웨어만 사용하십시오.
  • Before any manipulation at an installed PV plant, switch it off first on the AC-side, and then on the DC side of the inverter or the charge controller.
  • 빛에 노출된 태양광 모듈에 연결된 전선을 분리할 때 전기 아크가 발생할 수 있습니다. 아크는 화상을 일으키거나 화재를 일으키거나 안전(치명적인 감전까지) 문제를 일으킬 수 있습니다.
  • 잔량 확인tage before starting and observe the local safety-relevant regulations for such working conditions.
  • 정상적인 조건에서 태양광 모듈은 더 많은 전류 및/또는 볼륨을 생성할 수 있습니다.tage(여기서: 30V DC)는 표준 테스트 조건에서 보고된 것보다 큽니다.
  • DC vol과의 접촉tag30V 이상의 e는 잠재적으로 위험합니다. 태양광에 노출된 모듈을 배선하거나 취급할 때는 주의하십시오.
  • 동일한 정격 출력 전류를 가진 모듈만 직렬로 연결하십시오. 모듈을 직렬로 연결하면 총 볼륨tage는 개별 모듈 vol의 합계와 같습니다.tag에스.
  • 동일한 볼륨의 모듈 또는 모듈의 시리즈 조합만 연결하십시오.tage in parallel. If modules are connected in parallel, the total current is equal to the sum of the individual module or series combination currents.
  • 특정 태양광 시스템 내에서 항상 동일한 유형의 모듈을 사용하십시오.
  • If the sum of short circuit currents of the parallel-connected modules exceeds the reverse current, string diodes or fuses have to be used in each string of modules connected in parallel. These string diodes or fuses have to be qualified for the maximum expected current and voltage. The fuse rating value is also corresponds to the maximum reverse current that a module can withstand. The reverse current value can be found on the product label, in the product datasheet or in chapter 8 of the installation manual. Observe the instructions and safety precautions for all other components used in the system, including wiring and cables, connectors, DC-breakers, inverters, etc.
  • 전기 설비에 사용이 승인된 적절한 안전 장비(절연 도구, 절연 장갑, 신발 등)를 사용하세요.

구성

  • 정상적인 조건에서 광전지 모듈은 더 많은 전류 및/또는 전압을 생성하는 조건을 경험할 가능성이 있습니다.tage than reported at Standard Test Conditions (STC: 1000 W/ m2, AM 1.5, and 250C/770F cell temperature) or Bifacial nominal power index(BNPl front irradiance 1000 W/m2, back irradiance 135 W/m2 AM 1.5, and 25 OC/770F cell temperature). The short-circuit current (ISC) should be multiplied by a factor of 1.25 and the open-circuit voltag구성 요소 부피를 결정할 때 설치 위치에 대해 기록된 최저 및 최고 주변 온도를 기준으로 e(VOC)에 최대 1.25의 계수를 곱해야 합니다.tage 등급, 도체 전류 등급, 퓨즈 크기 및 PV 출력에 연결된 제어 장치 크기.
  • 권tages는 PV 모듈이 직렬로 직접 연결된 경우 가산이고, PV 모듈이 직접 병렬로 연결된 경우 모듈 전류는 가산입니다. 전기적 특성이 다른 PV 모듈은 직렬로 직접 연결하면 안 됩니다. PV 모듈에 연결된 적절한 타사 전자 장치를 사용하면 다른 전기 연결이 가능하며 제조업체의 지정된 지침에 따라 설치해야 합니다.
  • 최대 볼륨tage of serial interconnection of the modules must be less than the maximum certified module’s system voltag이자형. 또한 최대 입력 볼륨tag인버터 및 시스템의 다른 전기 장치를 고려해야 합니다. 개방 회로 권tage of the array string needs to be calculated at the lowest expected a mbient temperature forthe location. The maximal system voltage for the module is indicated in the module’s datasheet.
  • Accordingly, for BLACKSTAR, SOLID or MAGNUS series modules, the values of ISC and VOC under STC or BNPI marked on this module should be multiplied by a factor of 1,25 when determining component voltage ratings, conductor current ratings, fuse sizes, and size of controls connected to the PV output. In the USA, referto Section 690-8 of the National Electrical Code (N EC) for an additional multiplying factor of 125 percent (80 percent de-rating) which may be applicable.

과전류 보호 장치(OCPD)

  • When the potential reverse current of a PV string exceeds the rated SoliTek PV module series fuse rating (values indicated at the module datasheet) an overcurrent protection device (OCPD) must be used.
  • An overcurrent protection device is required for each series string if more than two series are connected in parallel.
  • In this case, it is needed to use one fuse per string rated at 1.25 x Isc or higher (Isc is the PV module’s short circuit current at STC). A PV fuse on each PV string will protect the PV modules and conductors from overcurrent faults and help minimize any safety hazards.
  • The PV fuse will also isolate the faulted PV string so the balance of the PV system can continue to generate electricity.
  • 퓨즈 amp 등급 ≥ 1.25 x Isc
  • 사용 가능한 PV 퓨즈 카탈로그에서 다음으로 높은 표준 등급을 선택하십시오.
  • Isc = 표준 테스트 조건(STC)에서 한 모듈의 단락 전류.
  • SoliTek 모듈의 Isc 값을 고려할 때 설치에 사용되는 PV 퓨즈의 올바른 값은 30A입니다. SoliTek은 양극 및 음극 도체 모두에 PV 퓨즈를 사용할 것을 권장합니다.

케이블 및 배선

SoliTek PV 모듈에는 대부분의 설치에 사용할 수 있는 PV 커넥터로 종단 처리된 두 개의 표준 햇빛 방지 출력 케이블이 제공됩니다. 양극(+) 단자에는 수 커넥터가 있고 음극(-) 단자에는 암 커넥터가 있습니다. 모듈 배선은 직렬 연결(즉, 수(+) - 암(-) 상호 연결)을 위한 것이지만 제조업체의 지침을 따르는 한 대체 배선 구성을 가질 수 있는 적합한 타사 전기 장치를 연결하는 데에도 사용할 수 있습니다.
PV 모듈의 최대 단락 전류에서 사용하도록 승인된 적절한 단면적을 갖춘 현장 배선을 사용하십시오. 모든 배선은 최소 정격이 1,8kV(1500V 이상)인 이중 절연 교차 연결 케이블이어야 합니다.tage) 최소 정격 온도는 90˚C(190°F)입니다. 전선 크기는 4mm²(12AWG) 이상입니다. 절연 유형은 사용된 설치 방법 유형에 적합해야 하며 IEC 61730 및 안전 등급 II 요구 사항을 충족해야 합니다.

  • 절연 수준: 1,8 kV(도체-도체).
  • 온도: 최소 -40°C ~ +90°C(-40°F ~ 190°F).
  • 도체 구성: 구리 순도가 99,9% 이상인 주석 도금 구리선.
  • 1차 절연: 가교 폴리에틸렌(XLPE), 햇빛과 습기에 강하고 난연성. 지하에 설치된 전선관 및 전선로에 적합합니다.
  • 단열재(재킷): 열가소성, 햇빛 저항성, 난연성, 방수성.
  • 절연체를 포함한 최소 케이블 외경 – 5,2mm(2,05인치).
  • 최소 도체 단면적 – 4mm²(12AWG).

SoliTek은 설치자가 PV 시스템의 직류(DC) 배선에 적합한 직사광선 저항 케이블만 사용할 것을 권장합니다. 케이블 및/또는 모듈의 기계적 손상을 방지하는 방식으로 케이블을 장착 구조에 고정해야 합니다. 케이블에 스트레스를 가하지 마십시오. 고정을 위해 햇빛에 강한 케이블 타이 및/또는 와이어 관리 클립과 같은 적절한 수단을 사용하십시오. 케이블은 햇빛에 강하고 방수가 되지만 가능하면 직사광선에 노출되거나 케이블이 물에 잠기지 않도록 하십시오.
접속함에서 케이블의 표준 길이는 1,2m(47,24인치)입니다. 시스템에서 두 개의 패널이 상호 연결되도록 의도되었습니다.

접지

  • Module grounding must be done in accordance with the electrical design and construction specifications, procedures, regulations and other special grounding requirements applicable to the installation sites. If grounding is needed, it should be done accordingly:

Framed type modules grounding
프레임에 접지 표시가 표시된 구멍은 접지용으로만 사용할 수 있습니다. 모듈 프레임에 추가 접지 구멍을 뚫지 마십시오.
The grounding conductor or strap may be copper, copper alloy, or any other material acceptable foruse as an electrical conductor in accordance with local electric codes and regulations.
접지선은 적절한 접지 전극을 사용하여 지구에 연결되어야 합니다.
A bolted connection is required; it incorporates:

  • M4의 볼트 크기.
  • 볼트 머리 아래의 톱니 와셔 또는 톱니 볼트는 양극 처리된 프레임과 같은 비전도성 코팅을 관통해야 합니다.
  • M4 볼트에 적합한 고정 너트입니다.
  • 모든 하드웨어는 비철금속, 300 시리즈 스테인리스강으로 제작되거나 적절하게 부식 방지 처리되어야 합니다.
  • 너트를 잠글 때 권장되는 토크는 2 Nm ² 2.2 Nm (1,48 ² 1,62 ft-lb)입니다.
  • 접지 볼트는 모든 연결 요소를 통과해야 합니다.

SoliTek-SOLID-Series-Solar-Modules-FIG-1

  • PV 모듈의 금속 프레임을 접지하기 위해 나열되고 식별된 장치는 모듈의 노출된 금속 프레임을 접지된 장착 구조에 접지할 수 있습니다.
  • In any case the grounding screws or other parts have to be used separately from the mounting parts of the module.
  • Alternate grounding options built through the mounting system are acceptable as long as they have been IEC and UL approved.
  • Grounding resistance of the grounding structure shall be reached according to local regulations, Eurocodes, or other legal normative references.

Frameless type modules grounding

  • Due to that modules are without frame, grounding is not forseen. Other PV plant equipment should be grounded according to the local and national electrical codes.

커넥터

  • Connectors for SoliTek PV panels are Stäubli MC4-Evo 2. Keep connectors dry and clean and ensure that connector caps are hand-tight before connecting the modules.
  • 젖거나 더럽거나 결함이 있는 커넥터로 전기 연결을 시도하지 마십시오.
  • 커넥터의 햇빛 노출과 물 침수를 피하십시오. 커넥터가 땅이나 지붕 표면에 놓이지 않도록 하십시오.
  • Do not disconnect under load. Faulty connections can result in arcs and electrical shock.
  • 모든 전기 연결부가 단단히 고정되어 있는지 확인하십시오. 모든 잠금 커넥터가 완전히 맞물려 잠겼는지 확인하십시오.

바이패스 다이오드

The PV module’s junction box contains 3 bypass diodes (one in each part of split junction box; Schottky type) connected in parallel with the PV cell strings. In the case of partial shading (hot-spot effect), the diodes bypass the current generated by the non-shaded cells, therebylimiting module heating and performance losses.
바이패스 다이오드는 과전류 보호 장치가 아닙니다. 바이패스 다이오드는 부분적인 음영이 있는 경우 셀 스트링에서 전류를 전환합니다. 이 다이오드의 특성:

  • 권tage 등급 - 50V.
  • 전류 정격 - 25A.

화재 등급 등급

  • SoliTek SOLID Bifacial 및 Blackstar 모듈은 IEC 화재 시험을 통해 승인을 받았으며 가연성 등급 A를 달성했습니다. 화재 시험은 IEC 127-5의 A.300 항목에 규정된 대로 11,81mm(2.5인치)당 61730mm(2인치)의 경사에서 수행되었습니다.
  • SoliTek SOLID Bifacial has fire rating of 28 according to UL1703-2 standard. SoliTek Blackstar has fire rating of 29 according to UL1703-2 standard.

기계적 장착

  • The mechanical loads described in this manual are the test loads.
  • For calculating the equivalent maximum design loads, a safety factor of 1.5 (Design load×1.5 safety factor=Mechanical test load) needs to be considered in compliance with the requirements of the local laws and regulations.

일반 요구 사항

  • Modules can be mounted in landscape or portrait orientation. For the bifacial modules, in order to get notable bifacial gain, the distance between the bottom of the modules and the roof or ground surface shall be at least 0,8 m (31,50 inch).
  • Also, the bifacial gain increases significantly if modules are installed above white, light-reflecting surfaces (under surfaces with high albedo value).
  • If the mounting rails are installed across the module, the bifaciality effect will be lower due to back-side cells shading.
  • 장착 시스템에 포함된 안전 규정 및 설치 지침을 준수하십시오. 필요한 경우 자세한 내용은 공급업체에 직접 문의하세요.
  • The modules must be safely set onto the mounting rail.
  • The whole rail supporting the photovoltaic system must be strong enough to resist potential mechanical pressures caused either by wind or snow, in accordance with local, regional and state safety (and other associated) standards.
  • The mounting system shall be tested and inspected by a third-party testing institution with static mechanical analysis capacity in accordance with local national standards or international standards.
  • Before installing modules on a roof, ensure that the roof construction is suitable.
  • In addition, any roof penetration required to mount the modules must be properly sealed to prevent leaks.
  • 마운팅 레일이 열팽창으로 인해 확장될 때 변형되거나 모듈에 영향을 미치지 않는지 확인하십시오.
  • The module can appear thermal expansion and cold contraction; thus, the interval between two adjoining modules shall be no lesser than 10 mm (0,39 inch).
  • 유리 표면과 모듈 프레임에 구멍을 뚫지 마십시오. 그러면 보증이 무효화됩니다.
  • The mounting method must not result in the direct contact of dissimilar metals with the aluminum frame of the modules that will result in galvanic corrosion.

장착 부품은 내구성, 부식 방지 및 자외선 차단 기능이 있는 재질로 만들어야 합니다(스테인리스 강철 및 양극산화 처리된 알루미늄 부품이 권장됨).

CL로 장착AMPS

  • 최소 4개의 라미네이트 cl을 사용하십시오.amps 마운팅 레일에 모듈을 고정합니다. 모듈 clamps 금속 부품이 전면 또는 후면 유리에 닿지 않아야 합니다. 이 유형의 cl을 선택할 때amp- 장착 방법, 최소 XNUMX개의 cl 사용amp각 모듈의 s; 두 clamps는 각 긴 면에 부착되어야 합니다. 지역 바람 및 눈 하중에 따라 추가 clamp모듈이 부하를 견딜 수 있는지 확인하기 위해 필요할 수 있습니다.
  • Clamps 조임 토크는 최소 15Nm(11,06ft-lb)이어야 하지만 20Nm(14,75ft-lb)를 넘지 않아야 합니다. 일반적으로 두 개의 알루미늄 프로가 15Nm(11,06ft-lb)에 도달하면files는 서로 닿아 있습니다. 경사가 45° 이상인 경사 지붕에 세로 방향으로 모듈을 설치하는 경우 모듈 하단에 추가 후크가 필요합니다.

SoliTek-SOLID-Series-Solar-Modules-FIG-2 SoliTek-SOLID-Series-Solar-Modules-FIG-3

SOLID Black, Semi-clear, Satin, Agro Frameless

횡단 레일이 있는

SoliTek-SOLID-Series-Solar-Modules-FIG-4 SoliTek-SOLID-Series-Solar-Modules-FIG-5SoliTek-SOLID-Series-Solar-Modules-FIG-6

BLACKSTAR, SOLID Black 35(40) mm, SOLID Semi-clear 35(40) mm, SOLID Satin 35(40) mm, SOLID Agro 35(40) mm, Magnus Framed mounting

  • 이 유형의 cl을 선택할 때amp- 장착 방법, 최소 XNUMX개의 cl 사용amp각 모듈의 s; 두 clamps는 모듈의 각 측면에 부착되어야 합니다. 모듈 clamps가 전면 유리에 닿지 않아야 하고 프레임이 변형되어서는 안 됩니다.
  • 모듈 cl의 태양 전지에 그림자 효과가 발생하지 않도록 하십시오.amps.
  • The module frame is not to be modified under any circumstances. Do not to block the drain hole of the frame.
  • cl의 길이amp should be at least 30 mm (1,18 inch).
  • 더 클amp 모듈 프레임과 최소 5mm(0,2인치), 최대 10mm(0,4인치) 겹쳐야 합니다.

횡단 레일이 있는

SoliTek-SOLID-Series-Solar-Modules-FIG-7 SoliTek-SOLID-Series-Solar-Modules-FIG-8 SoliTek-SOLID-Series-Solar-Modules-FIG-9

횡단 레일이 없거나 레일이 긴 측면 프레임에 수직인 경우

SoliTek-SOLID-Series-Solar-Modules-FIG-10 SoliTek-SOLID-Series-Solar-Modules-FIG-11

삽입 시스템 포함

SoliTek-SOLID-Series-Solar-Modules-FIG-12

볼트로 장착

  • 모듈은 횡단 막대의 표시된 장착 구멍을 통해 8개의 MXNUMX 스테인리스 스틸 볼트로 부착 및 지지되어야 합니다. cl의 토크amp bolt has to be in range of 8÷10 Nm (5,9÷7,38 ft-lb). The transversal bars positioning is shown in Figure 3.
  • If additional mounting points are required, depending on the local wind and snow loads, then a mounting solution with clamp하드웨어를 선택해야 합니다.

SoliTek-SOLID-Series-Solar-Modules-FIG-13

  • Mounting with bolts can be done only through dedicated predrilled holes in the frame.
  • 새 구멍을 뚫는 것은 금지되어 있으며 보증이 무효화됩니다.

SoliTek-SOLID-Series-Solar-Modules-FIG-14 SoliTek-SOLID-Series-Solar-Modules-FIG-15

정션 박스의 위치

  • 접속 상자와 모듈 가장자리 사이의 거리나 접속 상자 위치 및 영역의 기타 치수는 아래에 표시된 그림을 참조하세요.

SoliTek-SOLID-Series-Solar-Modules-FIG-16

유지

  • 최적의 모듈 성능을 보장하기 위해 SoliTek은 다음을 권장합니다.
  • 필요한 경우 모듈의 유리 전면을 물과 부드러운 스폰지 또는 천으로 청소할 수 있습니다.
  • 잘 지워지지 않는 얼룩을 제거하려면 순하고 비연마성 세제를 사용할 수 있습니다.
  • 전기적, 기계적 연결을 주기적으로 점검하여 깨끗하고 안전하며 완전하고 안전한지 확인하십시오.
  • 문제가 있는 경우에는 허가/자격을 갖춘 사람과 상담하세요.

명세서

매개변수 \ 모델 블랙스타 나.96 SOLID Black (Semi-Clear) 나.96 35(40) mm 블랙스타 Satin B.96 매그너스 나.108
테스트 조건 에스티씨 에스티씨 에스티씨 에스티씨
정격 전력 455와트 455와트 445와트 510와트
전기 데이터 @STC
최대 전력(Pmax), W 455 455 445 510
권tage 최대 전력(Vmpp), V 29,71 29,71 29,40 33,34
최대 전력에서의 전류(Impp), A 15,31 15,31 15,14 15,30
개방 회로 Voltag전자(Voc), V 34,82 34,82 34,40 39,06
단락 전류(Isc), A 15,97 15,97 15,79 15,95
열 데이터
작동 온도 범위 -40oC ¼ 85oC(-40°F ¼ 185°F) -40oC ¼ 85oC(-40°F ¼ 185°F) -40oC ¼ 85oC(-40°F ¼ 185°F) -40oC ¼ 85oC(-40°F ¼ 185°F)
Pmax의 온도 계수 -0,362%/°C(°F) -0,362%/°C(°F) -0,362%/°C(°F) -0,362%/°C(°F)
Voc의 온도 계수 -0,265%/°C(°F) -0,265%/°C(°F) -0,265%/°C(°F) -0,265%/°C(°F)
Isc의 온도 계수 +0,036% /°C(°F) +0,036% /°C(°F) +0,036% /°C(°F) +0,036% /°C(°F)
크기 및 무게 데이터
길이 1762mm (XNUMXmm) 1762mm (XNUMXmm) 1762mm (XNUMXmm) 1961mm (XNUMXmm)
너비 1134mm (XNUMXmm) 1134mm (XNUMXmm) 1134mm (XNUMXmm) 1134mm (XNUMXmm)
두께 30mm (XNUMXmm) 35(40) mm 30mm 30mm (XNUMXmm)
무게 25,5kg 35(36)킬로그램 25,5kg 28,5kg
장착방법
Reference to the chapter 3.3 3.3 3.3 3.3
다른
최대 역전류, A 30
Fire    class, IEC 61730/UL 61730 A/유형 II
최대 시스템 볼륨tag전자, V 1500

Table 9. Electrical and mechanical parameters table.

매개변수 \ 모델 단단한 Semi- clear B.96 SOLID Black 나.96 단단한 Satin B.96 단단한 Agro 나.64
테스트 조건 에스티씨 에스티씨 에스티씨 에스티씨
정격 전력 455와트 455와트 445와트 300와트
전기 데이터 @STC
최대 전력(Pmax), W 455 455 445 300
권tage 최대 전력(Vmpp), V 29,71 29,71 29,40 19,60
최대 전력에서의 전류(Impp), A 15,31 15,31 15,14 15,31
개방 회로 Voltag전자(Voc), V 34,82 34,82 34,40 22,76
단락 전류(Isc), A 15,97 15,97 15,79 15,97
열 데이터
작동 온도 범위 -40oC ¼ 85oC(-40°F ¼ 185°F) -40oC ¼ 85oC(-40°F ¼ 185°F) -40oC ¼ 85oC(-40°F ¼ 185°F) -40oC ¼ 85oC(-40°F ¼ 185°F)
Pmax의 온도 계수 -0,30%/°C(°F) -0,30%/°C(°F) -0,30%/°C(°F) -0,30%/°C(°F)
Voc의 온도 계수 -0,25%/°C(°F) -0,25%/°C(°F) -0,25%/°C(°F) -0,25%/°C(°F)
Isc의 온도 계수 +0,045% /°C(°F) +0,045% /°C(°F) +0,045% /°C(°F) +0,045% /°C(°F)
크기 및 무게 데이터
길이 1772 ± 2 mm 1772 ± 2 mm 1772 ± 2 mm 1772 ± 2 mm
너비 1144±2 1144±2 1144 ± 2 mm 1144 ± 2 mm
두께 7,2mm (XNUMXmm) 7,2mm (XNUMXmm) 7,2mm (XNUMXmm) 7,2mm (XNUMXmm)
무게 33kg 33kg 33kg 33kg
장착방법
Reference to the chapter 3.2 3.2 3.2 3.2
다른
최대 역전류, A 30
Fire    class, IEC 61730/UL 61730 A/유형 II
최대 시스템 볼륨tag전자, V 1500

Table 10. Electrical and mechanical parameters table.

매개변수 \ 모델 SOLID Satin B.96 35 mm SOLID Satin B. 96 40mm SOLID AgroB.64 35 mm SOLID AgroB.64 40 mm
테스트 조건 에스티씨 에스티씨 에스티씨 에스티씨
정격 전력 445와트 445와트 300와트 300와트
전기 데이터 @STC
최대 전력(Pmax), W 445 445 300 300
권tage 최대 전력(Vmpp), V 29,40 29,40 19,60 19,60
최대 전력에서의 전류(Impp), A 15,14 15,14 15,31 15,31
개방 회로 Voltag전자(Voc), V 34,40 34,40 22,78 22,78
단락 전류(Isc), A 15,79 15,79 15,97 15,97
열 데이터
작동 온도 범위 -40oC ¼ 85oC(-40°F ¼ 185°F) -40oC ¼ 85oC(-40°F ¼ 185°F) -40oC ¼ 85oC(-40°F ¼ 185°F) -40oC ¼ 85oC(-40°F ¼ 185°F)
Pmax의 온도 계수 -0,362%/°C(°F) -0,362%/°C(°F) -0,30%/°C(°F) -0,30%/°C(°F)
Voc의 온도 계수 -0,265%/°C(°F) -0,265%/°C(°F) -0,25%/°C(°F) -0,25%/°C(°F)
Isc의 온도 계수 +0,036% /°C(°F) +0,036% /°C(°F) +0,045% /°C(°F) +0,045% /°C(°F)
크기 및 무게 데이터
길이 1762mm 1762mm 1762mm (XNUMXmm) 1762mm (XNUMXmm)
너비 1134mm (XNUMXmm) 1134mm (XNUMXmm) 1134mm (XNUMXmm) 1134mm (XNUMXmm)
두께 35mm (XNUMXmm) 40mm (XNUMXmm) 35mm (XNUMXmm) 40mm (XNUMXmm)
무게 35kg 36kg 35kg 36kg
장착방법
Reference to the chapter 3.3
다른
최대 역전류, A 30
Fire    class, IEC 61730/UL 61730 A/유형 II
최대 시스템 볼륨tag전자, V 1500

Table 11.Electrical and mechanical parameters table.

  • The electrical characteristics are within of the indicated values of ISC (φISC) ±3%, VOC (ϕVOC) ±3,5% and PMPP (ϕPmax) ±5%, under Standard Test Conditions (STC) (irradiance of 1000 W/m²,AM 1.5 spectrum, and a cell temperature of 25°C / 77°F)
  • 모든 SoliTek SOLID PV 패널은 전기 안전 등급 II에 해당합니다.

책임의 부인

  • SoliTek이 이 지침에 따라 태양광 시스템의 설치, 작동, 적용 및 유지 관리를 제어하는 ​​것은 불가능하기 때문입니다. SoliTek은 그러한 설치, 작동, 사용 또는 유지 관리로 인해 또는 이와 관련하여 발생하는 손실, 손상 또는 비용에 대해 책임을 지지 않으며 책임을 명시적으로 부인합니다.
  • SoliTek will not take any responsibility for any possible violation of patent rights and third-party rights that are related to the application of the solar energy system. No permission of patents is given through implication.
  • The information of this instruction is from the knowledge and experiences of SoliTek. However, the instructions and suggestions of this instruction do not make an external or internal of guarantee. SoliTek reserves the right to revise this instruction, products and all the information about products without prior notification to customers.

www.solitek.eu

자주 묻는 질문

  • Q: What should I do before installing the PV modules?
    • A: Read this entire guide, understand all instructions, and ensure compliance with all local, state, and federal regulations. Consult a certified building specialist for the structural integrity of the dwelling.
  • Q: Can I install the PV modules myself without professional training?
    • A: This documentation is not a complete installation manual for personnel not specifically trained in PV-modules. It serves as a general but strictly mandatory reference for the installer. Professional installation is highly recommended.
  • Q: What happens if I don’t follow the instructions in this guide?
    • A: Failure to follow instructions may damage system components, endanger personnel, damage property, or invalidate the panel warranty.
  • Q: Is it safe to work on a rooftop during installation?
    • A: Do not attempt to work on a rooftop until safety precautions have been identified and taken, including fall protection measures, ladders or stairways, and personal protective equipment (PPE). Avoid adverse conditions like strong winds or wet/frosted roofs.
  • Q: How should I store the PV modules before installation?
    • A: Store pallets in a cool and dry location until the PV modules are ready to be unpackaged. Do not exceed the maximum stacking height indicated on the packaging.

문서 / 리소스

PDF thumbnailSOLID Series Solar Modules
Installation Guide · SOLID Series Solar Modules, SOLID Series, Solar Modules, Modules

참고문헌

질문하기

Use this section to ask about setup, compatibility, troubleshooting, or anything missing from this manual.

질문하기

Ask about setup, compatibility, troubleshooting, or anything missing from this manual. Name and email are optional.