FEIG MRM103 Mid Range Reader Module

모델

메모
With this edition of the document, all previous editions become void. Indications made in this manual may be changed without previous notice. Copying of this document and giving it to others and the use or communication of the contents thereof are forbidden without express authority. Offenders are liable to the payment of damages. All rights are reserved in the event of the grant of a patent or the registration of a utility model or design. Composition of the information in this document has been done to the best of our knowledge. FEIG ELECTRONIC GmbH does not guarantee the correctness and completeness of the details given in this manual and may not be held liable for damages ensuing from incorrect or incomplete information. Since, despite all our efforts, errors may not be completely avoided, we are always grateful for your useful tips. The instructions given in this manual are based on advantageous boundary conditions. FEIG ELECTRONIC GmbH does not give any guarantee promise for perfect function in cross environments and does not give any guarantee for the functionality of the complete system which incorporates the subject of this document. FEIG ELECTRONIC GmbH calls explicit attention that devices which are subject of this document are not designed with components and testing methods for a level of reliability suitable for use in or in connection with surgical implants or as critical components in any life support systems whose failure to perform can reasonably be expected to cause significant injury to human health. To avoid damage, injury or death the user or application designer must take reasonably prudent steps to protect against system failures. FEIG ELECTRONIC GmbH assumes no responsibility for the use of any information contained in this document and makes no representation that they are free of patent infringement. FEIG ELECTRONIC GmbH does not convey any license under its patent rights nor the rights of others.
안전 지침
- 장치는 제조업체가 설계한 의도된 목적으로만 사용할 수 있습니다.
- 사용 설명서는 각 사용자가 항상 편리하게 사용할 수 있도록 보관해야 합니다.
- 제조사에서 판매 또는 권장하지 않은 예비 부품 및 추가 장치의 무단 변경 및 사용은 화재, 감전 또는 부상을 유발할 수 있습니다. 이러한 승인되지 않은 조치는 제조업체의 책임을 배제합니다.
- 구입 당시 유효한 문제의 제조업체 책임 규정은 장치에 대해 유효합니다. 제조업체는 설명서의 부정확성, 오류 또는 누락에 대해 법적 책임을 지지 않거나 장치에 대한 자동 설정 매개변수 또는 장치의 잘못된 적용에 대해 법적 책임을 지지 않습니다.
- 수리는 제조업체에서만 실행할 수 있습니다.
- Installation, operation, and maintenance procedures have to be carried out by professional and qualified personnel.
- 장치의 사용 및 설치는 국가의 법적 요구 사항 및 지역 전기 규정을 준수해야 합니다.
- 장치 작업 시 유효한 안전 규정을 준수해야 합니다.
- 장치를 만지기 전에 항상 전원 공급을 차단해야 합니다. 장치가 볼륨이 없는지 확인하십시오.tage 측정을 통해. 작동 제어(LED)의 페이딩은 전원 공급 중단이나 장치의 전원 부족을 나타내는 표시가 아닙니다.tage!
메모:
- Wearers of pacemakers
- Although this device does not exceed the permissible limits for electromagnetic fields, you should keep a minimum distance of 25 cm between the device and your pacemaker and not stay in the immediate vicinity of the device or the antenna for long periods of time.
History of documentation
| 개정 | 데이터 | 설명 |
| 0e | 2025년 XNUMX월 | 초기 버전 |
| 1e | 2025년 XNUMX월 | 버그 수정 |
Supported documents
| 아니요. | Supported documents | Doc.No. |
| [1] | 추가 정보 https://www.feig.de/en/login/ | |
| [2] | 수동 | H50420-xe-ID-B |
| [3] | Quick Start PR(M)103-USB | M50630-xde-ID-B |
| [4] | Quick Start MR(M)103-A | M50628-xde-ID-B |
| [5] | Quick Start MR103-E | M50629-xde-ID-B |
| [6] | Quick Start MR(M)103-USBC | M50627-xde-ID-B |
기호의 설명
| 상징 | 설명 |
| VDC/ |
직접 권tag전자 기호 |
성능 특징
일반 정보
- All reader variants described here have been developed for contactless data exchange with transponders whose operating frequency is 13.56 MHz.
- The ID PR103 has an integrated antenna and works with a transponder-dependent, typical reading range of 20 cm. The reader is equipped with a USB interface for communication with the host.
- The ID MR103 variants are equipped with a connection for an external antenna and work with a transponder-dependent, typical reading range of 40 cm.
- The following interfaces are available for communication with the host: RS232, USB, USBC, Ethernet.
- The “Anticollision” function enables the simultaneous reading of up to 100 x ISO15693 or 20 x I-CODE1 transponders.
- The reader variants are available as a housing version and as a module version.
Reader type code
| 판독기 유형 | 버전 | 인터페이스 |
| 79 (Hex.: 0x4F) | A | RS232 |
| USB | USB 2.0 | |
| USB-C | USB-C | |
| E (Ethernet) | 랜 |
탭 1: 판독기 유형
위에view

Reader versions
| 리더 유형 | 펌웨어 | 버전 | 인터페이스 |
| ID MR103-USB | 기준 | 주택 | USB |
| ID MRM103-USB | 기준 | 모듈 | USB |
| ID MR103-USBC | 기준 | 주택 | USB-C |
| ID MR103-A | 기준 | 주택 | RS232 |
| ID MRM103-A | 기준 | 모듈 | RS232 |
| ID MR103-E | 이더넷 | 주택 | 랜 |
| ID PR103-USB | 기준 | 주택 | USB |
| ID PRM103-USB | 기준 | 모듈 | USB |
탭 2: 독자용 버전
지원되는 작동 모드

탭 3: 작동 모드
제공 범위
- 1 x 장치
- 1 x Quick Start document
사이버 보안
Cyber Security (MR103-E)
장치 시운전
중요 공지 In order to comply with the requirements of the European Radio Equipment Directive (RED) 2014/53/EU article 3 (3), points (d), the following points must be taken into account for the product ID MR103-E:
- When using the network interface (Ethernet), it may be necessary to create at least one user to enable various functions such as changing the configuration. The user and the password MUST be set by the person who puts the device into operation on first use before it is logically connected to a network or by an authorized entity within a network where access is limited to authorized entities.
- When security and/or network assets (keys, certificates, ethernet configuration parameters) are transferred via network interface (Ethernet) TLS encryption must be used to secure the communication.
Cyber Security related Firmware Updates
중요 공지: In order to comply with the requirements of the European Radio Equipment Directive (RED) 2014/53/EU article 3 (3), points (d), you are required to register in the FEIG download area under https://www.feig.de/en/ and subscribe to notifications for cybersecurity-related firmware and software updates for the product ID MR103-E.
Firmware downgrade
중요 공지: A firmware downgrade to older major release versions is not possible in order to prevent old major versions with known cyber security vulnerabilities from being executed on the device.
설치
Housing version
- The readers are designed for indoor applications.
- Wall and under-counter mounting are possible with the optionally available mounting kit.
8.1을 보세요 Wall mounting or under-counter mounting
치수

Modul version
The Module version is intended for installation in customer housings.
Modul dimension [mm]

인터페이스 오버view 및 연결
Depending on the reader variant, different connections and interfaces are available.

Interface designation
| 커넥터 | 설명 |
| X1 | Power supply 12 – 24V DC/ ± 10% |
| X2 | RS232 & Power supply 12 – 24V DC/ ± 10% |
| X3 | USB / USBC |
| X4 | 10/100Tbase Network interface (RJ45) LAN |
| 개미 1 | Connector ext. antenna (Impedance Ω) |
탭 4: 커넥터 설명
Antenna connection ANT1
There is an SMA socket on the circuit board or on the housing for connecting the external antenna.
메모:
- The antenna must be adjusted to the value 50 Ω (50 Ω L 15°).
- The optimum operating quality of the antenna should be in the range QB = 10…20. To determine the operating quality, the antenna must be supplied with a 50 Ω source, e.g. a network analyzer or a frequency generator.
- When connecting an antenna, make sure that it does not exceed the permissible limit values of the national regulations regarding radio equipment.
- The maximum tightening torque of the SMA sockets is 0.45 Nm.
DC 볼륨tage on antenna connector ANT1
DC 권tage can be applied from the reader to the ANT1 antenna connection. This DC voltage can be used to supply an LED, for examp르.
메모:
- DC 권tage is only designed for low currents. The DC voltage (6,9 V± 1 V) can be loaded up to a maximum of 5mA.
- Only antennas that are suitable for DC voltage and do not short-circuit the DC voltage may be connected.
- When connecting other devices (e.g. VSWR meters), make sure that they are also suitable for DC voltage.
- 이번 DC 권tage is not suitable for supplying the automatic antenna tuner ID ISC.DAT.
위에view 전원 공급
| ID PR(M)103-USB | X3 | 5 VDC / 500 mA (via USB) |
| ID MR(M)103-A | X2 | 핀 1 = GND
Pin 2 = RxD Pin 3 = TxD Pin 4 = GND Pin 5 = 12 bis 24V DC/ |
| ID MR103-E | X1 | External Power Supply Unit (12 bis 24V DC/ |
| ID MR(M)103-USB | X1 | External Power Supply Unit (12 bis 24V DC/ |
| ID MR103-USBC | X3 | 5V DC / |
탭 5: 전원 공급 장치
X1: External Power Supply*
- The device may only be supplied by a power source in accordance with EN 62368-1 Chapter Q.1 Power sources of limited power or with a power supply unit certified in accordance with NEC Class 2/LPS.
- For more information on available power supply units, see Accessories.
Connector for external Power Supply Unit
X2 : RS232 Interface (ID MR103-A)
The transmission parameters can be configured via software protocol.
Connector X2 / Pin Assignment
X3 : USB-Interface (ID PR103-USB / ID MR103-USB, USBC)
The USB interface is connected via socket X3 (ID PR103-USB / ID MR103-USB / -USBC). The assignment is standardized. The data rate of the reader is limited to 12 Mbit (USB Full Speed). A standard USBC cable can be used.
메모: Maximum length of the USB cab e: ≤ 3 m
X4: Ethernet-Interface (ID MR103-E)
- The reader has an integrated 10/100 base-T network interface with standard RJ-45 connection. The connection is made via X4 and has automatic crossover detection in accordance with the 1000BASE-T standard.
- For structured cabling, at least CAT5 category cables should be used. This guarantees problem-free operation at 10 Mbps or 100 Mbps.
- A prerequisite for using the TCP/IP protocol is that each device on the network has its own IP address. All readers have a factory-set IP address.
- The transmission parameters can be configured via software protocol.
| 회로망 | 주소 |
| IP 주소 | 192.168.10.10 |
| 서브넷 마스크 | 255.255.255.0 |
| 포트 | 10001 |
| 디씨에프(DHCP) | ON |
탭 8: Default setting Ethernet Interface
메모:
- The reader has a DHCP-capable TCP/IP interface.
- A shielded STP (shielded and twisted pair) CAT5 cable must be used.
작동 및 표시 요소
Default settings for LED indication

라디오 승인
적합성 선언(CE)
- CE 적합성 선언
- Hereby, FEIG ELECTRONIC GmbH declares that the radio equipment type ID PRM103 / ID MRM103 is in compliance with Directive 2014/53/EU.
- EU 적합성 선언의 전체 내용은 다음 인터넷 주소에서 확인할 수 있습니다. https://www.feig.de/en/service/.
미국(FCC) 및 캐나다(IC)
메모: The RFID reader ID PR103 / MR103 contains the RFID module ID PRM103 / MRM103.
| 제품 이름: | ID PR103 / MR103 |
| 연방통신위원회(FCC) ID: IC: | PJMPRM103 PJMMRM103 6633A-PRM103 6633A-MRM103 |
| 공지사항
미국과 캐나다 |
이 장치는 FCC 규정의 15조 및 캐나다 산업부의 RSS-210을 준수합니다.
운영은 다음 두 가지 조건에 따라 이루어집니다. (1) 이 장치는 유해한 간섭을 일으키지 않으며, (2) 이 장치는 원치 않는 작동을 유발할 수 있는 간섭을 포함하여 수신된 모든 간섭을 수용해야 합니다. Unauthorized modifications may void the authority granted under Federal Communications Commission Rules permitting the operation of this device. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. |
| 무선 주파수 방사선 노출 정보: | 이 장비는 통제되지 않은 환경에 대해 규정된 FCC 및 IC 방사선 노출 제한을 준수합니다. 이 장비는 라디에이터와 신체 사이에 최소 20cm의 거리를 두고 설치 및 작동해야 합니다. 이 송신기는 다른 안테나 또는 송신기와 함께 배치하거나 함께 작동해서는 안 됩니다. |
메모: FEIG ELECTRONIC GmbH의 명시적인 승인 없이 이 장비를 변경하거나 개조할 경우 이 장비 작동에 대한 FCC 승인이 무효화될 수 있습니다.
Installation with FCC / IC Approval
FCC-/IC-NOTICE: To comply with FCC-Part 15 Rules in the United States / with IC Radio Standards in Canada, the system must be professionally installed to ensure compliance with the Part 15 certification / IC certification. It is the responsibility of the operator and professional installer to ensure that only certified systems are deployed in the United States / Canada.
라벨 정보
- UThe following information must be placed at the outer side of the housing in which the reader is mounted.
- Contains FCC ID PJMPRM103 Contains FCC ID PJMMRM103
- Contains IC: 6633A-PRM103 Contains IC: 6633A-MRM103
기술 데이터
| 기계 데이터 | |
| Housing PR103 / MR103 | 플라스틱 ABS |
| 무게
PR103 MR103 |
150g
150g |
| Dimension PR103 / MR103
(wxhxd) |
(145 x 85 x 22)mm |
| Dimension PR103 / MR103 Module
(wxhxd) |
(145 x 77 x 17)mm |
| Weight Modul | 56g |
| Protection class PR103 / MR103 | 아이피 30 |
| 컬러 하우징 | RAL 9018(흰색) |
| 전기 데이터 | |
| 전원 공급 장치
· ID PR103-USB · ID MR103-A/-USB · ID MRM103-A/-USB · ID MR103-E · ID MR103-USBC |
· 5V DC · 12V DC up to 24V DC · 12V DC up to 24V DC · 12V DC up to 24V DC · Via USB-Type-C (Current at 1.5A) |
| 전력 소모량
ID PR103-USB ID MR103-A, USB, USBC, E |
최대. 최대 2.5W 6W |
| 안테나
PR(M)103-USB |
통합된 |
| 안테나 connector MR(M)103 | 1x SMA-socket (50 W) |
| 공급량tage on antenna output
MR103 |
6,9V DC ± 1V (5 mA) Antenna output |
| 동작 주파수
PR103-USB ID MR103-A, USB, USBC, E |
13,56MHz |
| 전력 전송
ID PR103-USB ID MR103-A, USB, USBC, E |
0.6W ± 2dB
1,2W ± 1dB 1,5W ± 1dB |
| Supported transponder | ISO15693, (ISO 18000-3 MODE 1), I-CODE1 |
| Reader modes
ID PR(M)103-USB ID MR(M)103-A, USB, USBC, ID MR(M)103-E |
ISO Host Mode, Scan Mode ISO Host Mode, Scan Mode
ISO Host Mode, Notification Mode |
| LED 1개 | 1 x multicolor LED; (green, blue, red) |
| 인터페이스
· ID PR(M)103-USB · ID MR(M)103-A |
· USB
· RS232 |
| · ID MR(M)103-USB
· IS MR(M)103-USBC · ID MR(M)103-E |
· USB
· USB · Ethernet (TCP/IP) |
| 특징 | Short-circuit detection (antenna)
온도 모니터링 |
| 환경 조건 | |
| 온도 범위 | -25°C ~ +55°C
-40°C ~ +85°C |
| 작업 저장 | |
| 상대 습도 | 5% – 95%(비응축) |
| 진동 | EN60068-2-6
10 Hz bis 150 Hz: 0,075 mm / 1 g |
| 충격 | EN60068-2-27
가속도: 30g |
| 승인 | |
| 무선 승인 | · EN 300 330
· FCC 47 CFR-Part 15 · RSS-Gen Issue 1, RSS-210 |
| · Europa / UK
· USA · Canada |
|
| 전자 영화 | EN 301 489 |
| 안전과 건강 | EN 62368-1
영어: 50364 영어 XNUMX 영어: 18031 영어 XNUMX |
| 낮은 볼륨tage 인체 노출
Cyber Security (MR103-E) |
|
부속품
| 주문번호 | 유형 | 설명 | |
| 1688.002.00 | ID NET.12V-B-EU Power Supply Unit 12V | Supply unit 100 – 240V AC, (Angled plug, EU),
Output: 12V DC/ ; 50Hz / 60Hz, 700mA |
|
| 3886.000.00 | ID NET.12V-B-GB Power Supply Unit 12V | Supply unit 100 – 240V AC, (Angled plug, GB) | |
| 3887.000.00 | ID NET.12V-B-US Power Supply Unit 12V | Supply unit 100 – 240V AC, (Angled plug, US) | |
| 7224.000.00 | ID MS.MR103/PR103-A | Wall mounting or under-counter mounting | |
| 7102.000.00 | ID CAB.RS-T | Cable for RS232 and Power Supply (ID MR103-A) | |
| 7103.000.00 | ID CAB.USB-AC | USB Interface cable, USB-A auf USBC | |
| 7104.000.00 | ID CAB.USB-CC | USB Interface cable, USBC auf USBC | |
| 외부 안테나 | |||
| 1663.000.00 | ID ISC.ANT340/240-A | Dim.: Protection.: | 340mm x 240mm x 9mm IP20 |
| 2396.000.00 | ID ISC.ANT340/240-B | 하우징이 없는 외부 안테나 | |
| 3249.000.00 | ID ISC.ANT310/310-A | Dim.: Protection.: | 318mm x 338mm x 30mm IP65 |
| 3512.000.00 | ID ISC.ANTS370/270 | Dim.: Protection.: | 370mm x 270mm x 27mm IP20 |
| 6612.000.00 | ID ANT240/180-A | Dim.: Protection: | 40mm x 180mm x 13mm IP30 |
| 6616.000.00 | ID ANTS240/180-A | Dim.: Protection: | 240mm x 180mm x 15mm IP30 |
| 1968.000.00 | ID ISC.ANT100/100-A | External antenna without housing Dim.: 40mm x 30mm x 6mm | |
| 1967.000.00 | ID ISC.ANT40/30-A | 하우징이 없는 외부 안테나
Dim.: 100mm x 100mm x 6mm |
|
탭 10: 부속품
Wall mounting or under counter mounting
- Remove the screws on the back of the reader.
- The mounting brackets are fastened with the previously removed screws.
- They can also be mounted rotated by 90° as an option.

메모: The mounting kit “ID MS.MR103/PR103-A” includes the four mounting brackets (See Accessories).
Serial Data Cable ID CAB.RS-T
| 핀 | 신호 | Farbe / Color | X2 |
| 1 | 접지 | 노란색 | ![]() |
| 2 | 수신 | 주황색 | |
| 3 | TxD | 갈색 | |
| 4 | 접지 | 검은색 | |
| 5 | 12 bis 24V DC/ |
빨간색 |

- 문서: 설치
- Id-Nr. Document Version: M50720-0e-ID-B
- 날짜: 30.10.25
연락처 정보
- © 저작권
- All brand names, product names or trademarks mentioned are the property of their respective owners.
- FEIG 전자 GmbH
- Industriestraße 1a
- 35781 바일부르크, 독일
- 전화: +49 6471 3109-0
- 홈페이지: https://www.feig.de/en/
- 이메일: ID-support@feig.de.
자주 묻는 질문
- 장치를 수정할 수 있나요?
- No, unauthorized changes and the use of spare parts and additional devices which have not been sold or recommended by the manufacturer may cause fire, electric shocks or injuries. Such unauthorized measures shall exclude any liability by the manufacturer.
- Who can perform repairs on the device?
- 수리는 제조업체에서만 실행할 수 있습니다.
- What should I do before handling the device?
- 장치를 만지기 전에 항상 전원 공급을 차단해야 합니다. 장치가 볼륨이 없는지 확인하십시오.tage by measuring. The fading of an operation control (LED) is no indicator for an
- interrupted power supply or the device being out of voltage!
- 최신 버전의 매뉴얼은 어디서 찾을 수 있나요?
- With this edition of the document, all previous editions become void. Indications made in this manual may be changed without previous notice. For the most current information, it is recommended to contact FEIG ELECTRONIC GmbH.
문서 / 리소스
![]() | MRM103 Mid Range Reader Module |
참고문헌
- CAB.RScab.rs
- 문서 번호문서 번호
- mailto:Identification-support@feig.defeig.de
- nord.denord.de
- feig.de/en/www.feig.de
- feig.de/en/login/www.feig.de
- feig.de/en/service/www.feig.de
- 사용자 설명서manual.tools