ENTTEC-로고

ENTTEC 73539 DIN PIXIE

ENTTEC-73539-DIN-PIXIE-FIG-1

제품 정보

명세서:

  • 맞춤형 프로토콜 생성 가이드
  • Compatible with ENTTEC pixel controllers: DIN PIXIE, PIXELATOR MINI, PIXELATOR MINI MK2, OCTO MK2, OCTO MK3
  • Firmware Version Requirements: V1.0 or above for some models, V2.0 or above for others, V4.0 or above for OCTO MK2

제품 사용 지침

소개:
ENTTEC Pixel controllers support over 20 default pixel protocols. The custom protocol feature allows users to create a custom protocol for pixel fixtures not covered by default protocols without the need for new firmware.

설치 요구 사항:

  • Datasheet of the desired pixel fixture
  • Computer to access the device settings page
  • For ENTTEC Ethernet Controller: Device IP address (DHCP or static)
  • For DIN PIXIE: EMU Software for configuration

Guide to Custom Protocol Creation:

  1. Verify datasheet for compatible pixel protocol
  2. Navigate to the Device’s User Interface to enablethe  custom protocol feature
  3. Adjustthe  pixel fixture’s data voltage timing viathe  web interface based othe n datasheet

Step 1: Verify Datasheet for Compatible Protocol

  1. Check the data transmission method from the datasheet
  2. Identify data transmission method (e.g., D1-D2-D3…Dn or C1-C2-D1-D2…Dn)
  3. Choose a supported protocol with a similar data transmission method

호환되는 펌웨어

사용자 정의 프로토콜 생성은 다음 ENTTEC 픽셀 컨트롤러에 제공됩니다.

제품유형 제품 펌웨어 버전
73539 DIN 픽시 V2.0 이상
70067 픽셀레이터 미니 V2.0 이상
70068 픽셀레이터 미니 MK2 V1.0 이상
71521 옥토 MK2 V4.0 이상
71522 옥토 MK3 V1.0 이상

소개

  • ENTTEC Pixel controllers support more than 20 pixel protocols by default. In the event of missing protocol, this custom feature allows users to create a custom protocol for the desired pixel fixture anytime without having to submit a support request for new firmware.
  • 이 기능을 사용하면 사용자가 볼륨을 조정할 수 있습니다.tage 데이터 전송 방법이 지원되는 프로토콜과 일치하는 경우 지원되는 프로토콜을 기반으로 한 타이밍입니다.
  • 이 문서에서는 사용자 정의 픽셀 프로토콜을 생성하고 기준을 확인하기 위한 설정 지침을 제공합니다.

설정 요구 사항

사용자 정의 프로토콜을 생성하려면 다음이 필요합니다.

  1. 데이터시트: Obtain the datasheet of the desired pixel fixture to gather necessary information. Contact the dealer or manufacturer for this document.
  2. 장치: Use a computer to access the device settings page.
  3. For the TEC Ethernet Controller: Obtain the device IP address, which can be either DHCP or static, based on your network settings. Discover the IP using the ENTTEC EMU app.
  4. For DIN PIXIE: Use the EMU Software for configuration.

맞춤형 프로토콜 생성 가이드

이 기능을 사용하면 사용자가 데이터 볼륨을 조정할 수 있습니다.tage timing to meet specific protocol needs. To create a custom protocol:

  1. 호환되는 픽셀 프로토콜에 대한 데이터시트를 확인하세요.
  2. 사용자 정의 프로토콜 기능을 활성화하려면 장치의 사용자 인터페이스로 이동하십시오.
  3. 픽셀 고정 장치의 데이터 볼륨을 조정합니다.tage 타이밍을 통해 web 제조업체의 데이터시트에 따른 인터페이스입니다.

1단계: 호환되는 프로토콜의 데이터시트 확인

  1. 데이터시트에서 원하는 프로토콜의 데이터 전송 방식을 확인하세요.
    1. The data transmission method implies how the data is forwarded. Below are demonstrated the common data transmission methods:
      • 가장 일반적인 방법은 추가 비트(예: D1-D2-D3…Dn) 없이 데이터를 전송하는 것입니다.
        Example: WB2812B의 데이터시트에서 캡처한 정보

        ENTTEC-73539-DIN-PIXIE-FIG-2

      • TM1814와 같은 일부 프로토콜에는 전면에 추가 데이터가 포함됩니다(예: C1-C2-D1-D2…Dn).
        Example: TM1814의 데이터시트에서 캡처한 정보

        ENTTEC-73539-DIN-PIXIE-FIG-3

  2. 장치에서 지원하는 일치하는 프로토콜을 지정하십시오(또는 위의 예에서 선택하십시오).ample) that shares the same data transmission method as your desired pixel protocol.
  3. 추가 구성을 위해 2단계로 진행하세요.

Step 2: Navigate to the Device’s Settings page to enable the custom protocol feature
In this step, the OCTO/PIXELATOR MINI Series and Din PIXIE are guided accordingly due to their distinct interfaces.
For ENTTEC Ethernet Controllers (OCTO/PIXELATOR MINI Series)

  1. Access to the OCTO/PIXELATOR MINI web 인터페이스
    1. Google Chrome을 권장합니다. web browser to access the OCTO/PIXELATOR MINI’s web 인터페이스.
    2. Free ENTTEC app, EMU can be used to discover OCTO/PIXELATOR MINI’s IP address. See the ENTTEC webwww.enttec.com 사이트에서 앱을 다운로드 받으세요.
    3. After entering the IP address of OCTO/PIXELATOR MINI, the user will land on the Home page of OCTO/PIXELATOR MINI’s User Interface.

      ENTTEC-73539-DIN-PIXIE-FIG-4
      Example of the OCTO homepage in Figure 1 indicates IP address 10.10.3.31, which was assigned by the DHCP server. For the out-of-box OCTO/PIXELATOR MINI that is connected directly to a computer (no DHCP server), the default IP address is 192.168.0.10.
      See OCTO/PIXELATOR MINI User Manual ‘Networking’ section for more information.

  2. Navigate to the Settings page – Output Setting.
    원하는 픽셀 고정 장치가 연결된 출력으로 이동합니다. 1단계에서 확인한 것과 동일한 전송 방법을 공유하는 픽셀 프로토콜을 드롭다운 목록에서 선택합니다.

    ENTTEC-73539-DIN-PIXIE-FIG-5

  3. Enable Custom protocol (Continue to Step 3)
    데이터 볼륨에 액세스하려면 '사용자 정의' 체크박스를 활성화하세요.tage 타이밍 설정. 사용자 정의 프로토콜을 비활성화하려면 선택을 취소합니다.

    ENTTEC-73539-DIN-PIXIE-FIG-6

DIN 픽시용

  1. USB Type-B를 사용하여 DIN PIXIE를 컴퓨터에 연결합니다.
  2. EMU 소프트웨어를 실행합니다.
  3. 장치를 검색하고 발견된 DIN PIXIE의 Conf를 클릭하세요.

    ENTTEC-73539-DIN-PIXIE-FIG-6

  4. Enable Custom Protocol (Continue to Step 3)
    Pick a pixel protocol from the dropdown list that shares the same transmission method verified in tp,1, and enable Custom.

    ENTTEC-73539-DIN-PIXIE-FIG-8

3단계: 맞춤 볼륨 설정tag전자 타이밍

  1. 볼륨 일치tage 원하는 프로토콜의 데이터시트에 있는 타이밍. 사용자 정의 프로토콜은 데이터 볼륨을 완료하기 위해 4개의 입력이 필요합니다.tage 타이밍 조정:
    권tage Timing Definition
    비트 0 하이 타임(T0H) 권tage 코드 0에 필요한 높은 시간.
    비트 1 하이 타임(T1H) 권tage 코드 1에 필요한 높은 시간.
    Overall Bit Time: 총 권tage time for a single bit.

    Lower limit = T0H+T0L

    Upper limit = T1H+T1L

    시간 재설정 총 권tag각 데이터 배치 사이의 데이터 전송을 재설정하는 데 필요한 낮은 시간.

    ENTTEC-73539-DIN-PIXIE-FIG-9

  2. 데이터시트 – 데이터 볼륨tage 타이밍 정보 Example
    WB2818B의 데이터시트에서
    • Locate the ‘Sequence Time’ table in WB2818B’s datasheet for the voltage 타이밍 범위.
    • 볼륨을 채우다tage 출력 설정의 사용자 정의 필드에 있는 타이밍 범위.

      ENTTEC-73539-DIN-PIXIE-FIG-10

중요한

  • ENTTEC recommends taking the median value of the range for the start.
  • 수정된 값을 적용하려면 사용자는 설정을 저장해야 합니다.
  • Fine adjustment of value required, followed by actual output test to optimise custom protocol for pixel fixture control.
  • ENTTEC recommends a trial run on the actual setup before finalising the custom protocol setup.
  • Typical issues of incorrect setup include, including and not limited to, failure to light up and output flickering.

결론

  • 이 가이드는 적격 ENTTEC 장치에 대한 맞춤형 프로토콜을 설정하는 방법을 시연하고 원하는 픽셀 고정 장치의 데이터시트 확인에 대한 기술 지식을 제공했습니다.
  • 다음 단계를 수행하면 사용자는 기술 지원이나 새 펌웨어 릴리스를 기다리지 않고 드롭다운 목록에 없는 사용자 정의 픽셀 프로토콜을 만들 수 있습니다. 질문이 있거나 올바른 정보를 찾는 데 어려움이 있는 경우 현지 사무소의 친절한 지원팀에 문의하세요.

자주 묻는 질문

How do I access the device settings page on my computer?

You can access the device settings page by connecting your computer to the device's network and entering the IP address in a web 브라우저.

Can I create a custom protocol without the datasheet?

It is recommended to have the datasheet to ensure accurate customization of the protocol based on the pixel fixture's specifications.

문서 / 리소스

ENTTEC 73539 DIN PIXIE [PDF 파일] 사용설명서
DIN PIXIE, PIXELATOR MINI, PIXELATOR MINI MK2, OCTO MK2, OCTO MK3, 73539 DIN PIXIE, 73539, DIN PIXIE, PIXIE

참고문헌

댓글을 남겨주세요

이메일 주소는 공개되지 않습니다. 필수 항목은 표시되어 있습니다. *