ENTTEC 73539 DIN PIXIE
제품 정보
명세서:
- 맞춤형 프로토콜 생성 가이드
- Compatible with ENTTEC pixel controllers: DIN PIXIE, PIXELATOR MINI, PIXELATOR MINI MK2, OCTO MK2, OCTO MK3
- Firmware Version Requirements: V1.0 or above for some models, V2.0 or above for others, V4.0 or above for OCTO MK2
제품 사용 지침
소개:
ENTTEC Pixel controllers support over 20 default pixel protocols. The custom protocol feature allows users to create a custom protocol for pixel fixtures not covered by default protocols without the need for new firmware.
설치 요구 사항:
- Datasheet of the desired pixel fixture
- Computer to access the device settings page
- For ENTTEC Ethernet Controller: Device IP address (DHCP or static)
- For DIN PIXIE: EMU Software for configuration
Guide to Custom Protocol Creation:
- Verify datasheet for compatible pixel protocol
- Navigate to the Device’s User Interface to enablethe custom protocol feature
- Adjustthe pixel fixture’s data voltage timing viathe web interface based othe n datasheet
Step 1: Verify Datasheet for Compatible Protocol
- Check the data transmission method from the datasheet
- Identify data transmission method (e.g., D1-D2-D3…Dn or C1-C2-D1-D2…Dn)
- Choose a supported protocol with a similar data transmission method
호환되는 펌웨어
사용자 정의 프로토콜 생성은 다음 ENTTEC 픽셀 컨트롤러에 제공됩니다.
| 제품유형 | 제품 | 펌웨어 버전 |
| 73539 | DIN 픽시 | V2.0 이상 |
| 70067 | 픽셀레이터 미니 | V2.0 이상 |
| 70068 | 픽셀레이터 미니 MK2 | V1.0 이상 |
| 71521 | 옥토 MK2 | V4.0 이상 |
| 71522 | 옥토 MK3 | V1.0 이상 |
소개
- ENTTEC Pixel controllers support more than 20 pixel protocols by default. In the event of missing protocol, this custom feature allows users to create a custom protocol for the desired pixel fixture anytime without having to submit a support request for new firmware.
- 이 기능을 사용하면 사용자가 볼륨을 조정할 수 있습니다.tage 데이터 전송 방법이 지원되는 프로토콜과 일치하는 경우 지원되는 프로토콜을 기반으로 한 타이밍입니다.
- 이 문서에서는 사용자 정의 픽셀 프로토콜을 생성하고 기준을 확인하기 위한 설정 지침을 제공합니다.
설정 요구 사항
사용자 정의 프로토콜을 생성하려면 다음이 필요합니다.
- 데이터시트: Obtain the datasheet of the desired pixel fixture to gather necessary information. Contact the dealer or manufacturer for this document.
- 장치: Use a computer to access the device settings page.
- For the TEC Ethernet Controller: Obtain the device IP address, which can be either DHCP or static, based on your network settings. Discover the IP using the ENTTEC EMU app.
- For DIN PIXIE: Use the EMU Software for configuration.
맞춤형 프로토콜 생성 가이드
이 기능을 사용하면 사용자가 데이터 볼륨을 조정할 수 있습니다.tage timing to meet specific protocol needs. To create a custom protocol:
- 호환되는 픽셀 프로토콜에 대한 데이터시트를 확인하세요.
- 사용자 정의 프로토콜 기능을 활성화하려면 장치의 사용자 인터페이스로 이동하십시오.
- 픽셀 고정 장치의 데이터 볼륨을 조정합니다.tage 타이밍을 통해 web 제조업체의 데이터시트에 따른 인터페이스입니다.
1단계: 호환되는 프로토콜의 데이터시트 확인
- 데이터시트에서 원하는 프로토콜의 데이터 전송 방식을 확인하세요.
- The data transmission method implies how the data is forwarded. Below are demonstrated the common data transmission methods:
- 가장 일반적인 방법은 추가 비트(예: D1-D2-D3…Dn) 없이 데이터를 전송하는 것입니다.
Example: WB2812B의 데이터시트에서 캡처한 정보
- TM1814와 같은 일부 프로토콜에는 전면에 추가 데이터가 포함됩니다(예: C1-C2-D1-D2…Dn).
Example: TM1814의 데이터시트에서 캡처한 정보
- 가장 일반적인 방법은 추가 비트(예: D1-D2-D3…Dn) 없이 데이터를 전송하는 것입니다.
- The data transmission method implies how the data is forwarded. Below are demonstrated the common data transmission methods:
- 장치에서 지원하는 일치하는 프로토콜을 지정하십시오(또는 위의 예에서 선택하십시오).ample) that shares the same data transmission method as your desired pixel protocol.
- 추가 구성을 위해 2단계로 진행하세요.
Step 2: Navigate to the Device’s Settings page to enable the custom protocol feature
In this step, the OCTO/PIXELATOR MINI Series and Din PIXIE are guided accordingly due to their distinct interfaces.
For ENTTEC Ethernet Controllers (OCTO/PIXELATOR MINI Series)
- Access to the OCTO/PIXELATOR MINI web 인터페이스
- Google Chrome을 권장합니다. web browser to access the OCTO/PIXELATOR MINI’s web 인터페이스.
- Free ENTTEC app, EMU can be used to discover OCTO/PIXELATOR MINI’s IP address. See the ENTTEC webwww.enttec.com 사이트에서 앱을 다운로드 받으세요.
- After entering the IP address of OCTO/PIXELATOR MINI, the user will land on the Home page of OCTO/PIXELATOR MINI’s User Interface.

Example of the OCTO homepage in Figure 1 indicates IP address 10.10.3.31, which was assigned by the DHCP server. For the out-of-box OCTO/PIXELATOR MINI that is connected directly to a computer (no DHCP server), the default IP address is 192.168.0.10.
See OCTO/PIXELATOR MINI User Manual ‘Networking’ section for more information.
- Navigate to the Settings page – Output Setting.
원하는 픽셀 고정 장치가 연결된 출력으로 이동합니다. 1단계에서 확인한 것과 동일한 전송 방법을 공유하는 픽셀 프로토콜을 드롭다운 목록에서 선택합니다.
- Enable Custom protocol (Continue to Step 3)
데이터 볼륨에 액세스하려면 '사용자 정의' 체크박스를 활성화하세요.tage 타이밍 설정. 사용자 정의 프로토콜을 비활성화하려면 선택을 취소합니다.
DIN 픽시용
- USB Type-B를 사용하여 DIN PIXIE를 컴퓨터에 연결합니다.
- EMU 소프트웨어를 실행합니다.
- 장치를 검색하고 발견된 DIN PIXIE의 Conf를 클릭하세요.

- Enable Custom Protocol (Continue to Step 3)
Pick a pixel protocol from the dropdown list that shares the same transmission method verified in tp,1, and enable Custom.
3단계: 맞춤 볼륨 설정tag전자 타이밍
- 볼륨 일치tage 원하는 프로토콜의 데이터시트에 있는 타이밍. 사용자 정의 프로토콜은 데이터 볼륨을 완료하기 위해 4개의 입력이 필요합니다.tage 타이밍 조정:
권tage Timing Definition 비트 0 하이 타임(T0H) 권tage 코드 0에 필요한 높은 시간. 비트 1 하이 타임(T1H) 권tage 코드 1에 필요한 높은 시간. Overall Bit Time: 총 권tage time for a single bit. Lower limit = T0H+T0L
Upper limit = T1H+T1L
시간 재설정 총 권tag각 데이터 배치 사이의 데이터 전송을 재설정하는 데 필요한 낮은 시간. 
- 데이터시트 – 데이터 볼륨tage 타이밍 정보 Example
WB2818B의 데이터시트에서- Locate the ‘Sequence Time’ table in WB2818B’s datasheet for the voltage 타이밍 범위.
- 볼륨을 채우다tage 출력 설정의 사용자 정의 필드에 있는 타이밍 범위.

중요한
- ENTTEC recommends taking the median value of the range for the start.
- 수정된 값을 적용하려면 사용자는 설정을 저장해야 합니다.
- Fine adjustment of value required, followed by actual output test to optimise custom protocol for pixel fixture control.
- ENTTEC recommends a trial run on the actual setup before finalising the custom protocol setup.
- Typical issues of incorrect setup include, including and not limited to, failure to light up and output flickering.
결론
- 이 가이드는 적격 ENTTEC 장치에 대한 맞춤형 프로토콜을 설정하는 방법을 시연하고 원하는 픽셀 고정 장치의 데이터시트 확인에 대한 기술 지식을 제공했습니다.
- 다음 단계를 수행하면 사용자는 기술 지원이나 새 펌웨어 릴리스를 기다리지 않고 드롭다운 목록에 없는 사용자 정의 픽셀 프로토콜을 만들 수 있습니다. 질문이 있거나 올바른 정보를 찾는 데 어려움이 있는 경우 현지 사무소의 친절한 지원팀에 문의하세요.
자주 묻는 질문
How do I access the device settings page on my computer?
You can access the device settings page by connecting your computer to the device's network and entering the IP address in a web 브라우저.
Can I create a custom protocol without the datasheet?
It is recommended to have the datasheet to ensure accurate customization of the protocol based on the pixel fixture's specifications.