Current CTRL042 Outdoor Wireless Control System

설치 전
- Carefully unpack the Light Grid Node. Inspect for defects before installing.
- Check electrical parameters. Ensure that the luminaire operating power is below 1000W, and its operating voltage is within 120 to 277 V AC
- Using the Light Grid Node outside its operating parameters will void its warranty.
- Validate Fixture Approval with Current. Prior to integrating the Internal Node in any luminaire, Current strongly recommends validation testing of the design to ensure Light Grid performance.
노드를 설비에 연결
필수 용품
- Light Grid Internal Node
- 조명
- Two #10 mounting screws of appropriate type and length (recommended)
Following the Wiring Diagram, perform the following steps:
- 노드의 L-In(검은색)을 조명기의 선(검은색)에 연결합니다.
- Connect L-Out (Red) of the node to AC Line input of the driver.
- Connect the neutral (white) of the node to the neutral (white) of the fixture.
- Connect the neutral (white) of the LED Driver/HID Ballast to the neutral (white) of the fixture.
For dimmable fixture, please perform the following extra steps:
- Connect the Dim- (grey or pink) of the node to the negative dimming wire of the LED Driver/HID Ballast.
- 노드의 Dim+(보라색)를 LED 드라이버/HID 안정기의 포지티브 디밍 와이어에 연결합니다.
배선도

경고
- RISK OF DAMAGE ON NODE
- 모든 배선 지침을 준수하지 않으면 노드 또는 고정 장치가 손상될 위험이 있습니다.
배선 설정
- 모든 배선 설정은 NFPA70: National Electrical code 및 CSA-22를 준수해야 합니다.
- Maximum temperature around the internal node: 70°C
노드 위치 및 설치
- The location of the node inside the Luminaire must be selected to keep the node as far away as possible from sources of heat or electrical electrical interferences sources, such as the lamp ballast/driver/power supply, or the light bulb or LED panel and its heatsink. Never install the node directly above these; The preferred location is in the lower part of the Luminaire below any source of heat.
Record the location the Internal Node is installed (since it doesn’t have GPS), this can be done by either manually recording it or using the Current Commissioning Light Grid App that is available on iOS to ensure the node is positioned in current location on the map view. - 노드 위치가 적절하게 배치된 2개의 나사 구멍 위치와 함께 안전하고 견고한 장착 지지 표면을 제공하는지 확인합니다.
- Attach the node into the fixture using 2 screws.
중요 참고 사항:
- All unused wires must be terminated with an appropriate UL CSA approved Wire Nut.
- 노드 하우징을 열거나 노드의 어떤 부분도 변경하지 마십시오.
- It is the integrator’s responsibility to ensure the temperature rating of the Light Grid node is never exceeded; Make certain that the ambient temperature around the node in its selected location can never exceed the maximum operating temperature (+70°C).
- The node by default will turn the luminaire ON until schedule is downloaded to the node from the CMS software.
Antenna Location & Installation
- To select the optimum antenna mounting point, read the following and refer to the illustrations (below) showing examples of the best, acceptable and unacceptable locations and orientations.
- The antenna must be mounted on a conductive (metal) surface. If the surface is made of non-conductive material (such as plastic), the inner surface where the antenna is to be installed should be lined with a thin metal sheet or foil tape (copper) approximately 6” to 12” diameter, with the antenna installed through the center of this me
- The antenna is to be installed through a 12mm diameter hole drilled through mounting surface.
- The mounting surface around this hole must be perfectly smooth, flat, and free of any burrs to insure a watertight seal.
- 구멍이 뚫린 지점의 안테나 장착면 두께는 1mm~6mm가 되어야 합니다.

LightGrid Internal Node 2.x Series Installation Guide
- A suitable location for both the node and antenna must be found which allows the antenna and its wire to be routed from the node installation point, to where it can be passed through the antenna mounting hole from the inside of the fixture.
- The antenna must be installed vertically with respect to the ground. Therefore, the surface it is mounted to must be horizontal.
- If the most suitable location is not perfectly horizontal at the point where the antenna is mounted, bevel washers may be used on either side of the mounting hole to insure the antenna will be perfectly vertical when installed.
- 고정물 외부에 있는 안테나의 선택된 위치는 l을 만나는 안테나 베이스에서 측정하여 주변 360도 수평으로 상당한 전도성(금속) 장애물이 없어야 합니다.amp fixture surface, to at least 12” (30 cm) above this surface. Plastic or glass features will not affect the antenna if they are at least 0.5 to 1” or 1-2cm away from it.
- 고정 장치의 안테나 위치는 일반적으로 이 장착 표면의 중심에 있는 고정 장치의 상단 표면에서 가장 높은 지점입니다.
- On hanging fixtures supported from above, the antenna may be mounted pointing downward, at a suitable location on the lower surface of the fixture housing.
- When installing the antenna, make sure installing the supplied O- ring and be very careful not to overtighten the M12 plastic screw and the antenna.
- Steps for the Antenna installation:
- Install O-ring on the lower flange of the SMA connector assembly (near the wire).
- Route the Antenna SMA connector assembly from the inside of the fixture to the antenna’s exit point.
- Fit the threaded portion of the SMA connector assembly through the 12 mm hole. Be careful not damaging the threads in the process.
- Install the serrated lock nut then screw the M12 plastic nut and tighten to a snug fit. To avoid risk of damages during transport, the antenna should be installed on the SMA connector only once the luminaire installation on site is completed.
- Screw the antenna on the SMA connector to a hand-tight to a snug fit. Do not over tighten.
라벨
- The Internal Node is supplied with 3 identical nameplate labels. One label is affixed on the node housing. The other two labels packaged with each node are to be affixed on a visible location on the exterior of the fixture and/or the base of the pole, for commissioning purposes.
- The MAC address of each internal Light Grid node is printed on the label both as barcode & plain text.

검증 테스트
- Non-Dimmable Fixture: To verify the installation of Light grid Internal Node, please follow these steps:
- Apply power to the fixture (120- 277V AC, 50/60 Hz)
- If the installation has been done correctly, the light will turn OFF briefly during the first 60 seconds after power is applied.
- Dimmable Fixture: To verify the installation of Lightgrid Internal Node, please follow these steps:
- Apply power to the fixture (120- 277V AC, 50/60 Hz)
- If the installation has been done correctly, the light output will visibly dim within the first 60 seconds after power is applied and then return to full brightness.
FCC 진술
FCC 성명:
메모: 이 장비는 FCC 규정 제15부에 따라 Class A 디지털 기기의 제한 사항을 준수하는 것으로 테스트 및 확인되었습니다. 이러한 제한 사항은 장비가 상업 환경에서 작동할 때 유해 간섭으로부터 합리적인 보호를 제공하도록 설계되었습니다. 이 장비는 무선 주파수 에너지를 생성, 사용 및 방출할 수 있으며, 사용 설명서에 따라 설치 및 사용하지 않으면 무선 통신에 유해 간섭을 일으킬 수 있습니다. 주거 지역에서 이 장비를 작동하면 유해 간섭이 발생할 가능성이 높으며, 이 경우 사용자는 자신의 비용으로 간섭을 수정해야 합니다.
FCC 방사선 노출 성명:
- 이 장비는 통제되지 않은 환경에 대해 규정 된 FCC 방사선 노출 제한을 준수합니다. 이 장비는 라디에이터와 신체 사이에 최소 20cm의 거리를두고 설치 및 작동해야합니다.
- 규정 준수에 책임이 있는 당사자의 명시적 승인 없이 변경이나 수정을 할 경우 사용자가 이 장비를 작동하는 권한이 무효화될 수 있습니다.
CAN ICES (A)/NMB (A):
이 장치에는 혁신, 과학 및 경제 개발 캐나다의 면허 면제 RSS를 준수하는 면허 면제 송신기/수신기가 포함되어 있습니다. 작동은 다음 두 가지 조건에 따릅니다.
- 이 장치는 간섭을 일으켜서는 안 됩니다.
- 본 장치는 원치 않는 작동을 일으킬 수 있는 간섭을 포함한 모든 간섭을 허용해야 합니다.
문서 / 리소스
![]() | CTRL042 Outdoor Wireless Control System |
Published: April 25, 2026