AquaCal SQ140ARDSBPA

AquaCal HeatWave SuperQuiet SQ140ARDSBPA 수영장 열펌프 사용 설명서

Model: SQ140ARDSBPA

1. 서론

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your AquaCal HeatWave SuperQuiet SQ140ARDSBPA Pool Heat Pump. Please read this manual thoroughly before attempting to install or operate the unit. Retain this manual for future reference.

2. 안전 정보

중요 안전 지침:

경고: Risk of electrical shock. This unit operates on 230 Volts (AC). Improper installation or maintenance can result in serious injury or death.

3. 제품 오버view

The AquaCal HeatWave SuperQuiet SQ140ARDSBPA is a high-efficiency pool heat pump designed for both heating and cooling your pool water. It features a durable construction and advanced controls for optimal performance.

3.1 주요 특징

3.2개의 구성요소

AquaCal HeatWave SuperQuiet SQ140ARDSBPA front view

그림 1: 앞쪽 view of the AquaCal HeatWave SuperQuiet SQ140ARDSBPA heat pump. This image displays the main body of the unit, including the control panel at the top and the water inlet/outlet connections at the bottom right.

AquaCal HeatWave SuperQuiet SQ140ARDSBPA control panel close-up

그림 2: Close-up of the control panel. This image highlights the digital display and control buttons used for setting temperature and operating modes.

4. 설정 및 설치

Proper installation is crucial for the performance and longevity of your heat pump. Consult a qualified professional for installation.

4.1 Site Selection and Placement

4.2 배관 연결

The unit features off-set plumbing connections. Connect the pool water return line to the unit's inlet and the heated/cooled water outlet to the pool return. Ensure a water flow rate between 30 and 70 Gallons Per Minute (GPM) for optimal operation.

4.3 전기 연결

5. 사용 설명서

Once installed and powered, the heat pump can be operated via its control panel.

5.1 제어판 기능

Refer to Figure 2 for the layout of the control panel. The panel typically includes:

5.2 원하는 온도 설정

  1. 를 누르세요 방법 버튼을 클릭하여 선택하세요 난방 or 냉각.
  2. 사용하세요 Up or 아래에 arrow buttons to adjust the desired pool water temperature.
  3. The unit will automatically begin heating or cooling to reach the set temperature, provided the pool pump is running and water flow is detected.

5.3 초기 시작

Upon initial startup, allow the unit to run for several hours to stabilize the pool water temperature. The time required will vary based on pool size and ambient conditions.

6. 유지관리

Regular maintenance ensures efficient operation and extends the life of your heat pump.

6.1 정기 청소

6.2 방한처리

In regions where temperatures drop below freezing, proper winterization is essential to prevent damage:

  1. Turn off the heat pump and disconnect its electrical power.
  2. Drain all water from the heat pump's plumbing lines and heat exchanger.
  3. Cover the unit with a breathable, protective cover to shield it from harsh weather.

7. 문제 해결

이 섹션에서는 발생할 수 있는 일반적인 문제에 대해 설명합니다. 복잡한 문제의 경우 자격을 갖춘 서비스 기술자에게 문의하십시오.

문제가능한 원인해결책
장치가 켜지지 않습니다No power supply; tripped breaker; control panel errorCheck electrical connections and circuit breaker. Consult manual for control panel error codes.
난방/냉방이 부족합니다Low water flow; dirty coils; incorrect temperature setting; ambient temperature too low/highEnsure pool pump is running and filter is clean. Clean coils. Verify set temperature.
비정상적인 소음Debris in fan; loose components; compressor issueInspect fan for obstructions. Tighten any loose parts. If compressor noise, contact service.
물 누출Loose plumbing connections; damaged heat exchangerCheck and tighten all plumbing connections. If leak persists, contact service.

8. 사양

Technical specifications for the AquaCal HeatWave SuperQuiet SQ140ARDSBPA:

9. 보증 및 지원

The AquaCal HeatWave SuperQuiet SQ140ARDSBPA is backed by strong factory support and a comprehensive warranty program. For specific warranty details, please refer to the warranty card included with your product or visit the official AquaCal web대지.

For authorized factory service or technical support, please contact AquaCal directly:

고객 지원: 800-878-0998