레즈너 UDXC-45

레즈너 UDXC-45 천연가스 유닛 히터 사용 설명서

Model: UDXC-45

1. 서론

The Reznor UDXC-45 is a 45,000 BTU natural gas unit heater designed for indoor use in various spaces, including commercial, industrial, and residential garages, workshops, and warehouses. This manual provides essential information for the safe and efficient installation, operation, and maintenance of your heater. Please read all instructions thoroughly before proceeding with installation or operation.

2. 안전 정보

경고: 부적절한 설치, 조정, 변경, 서비스 또는 유지보수는 재산 피해, 부상 또는 사망을 초래할 수 있습니다. 이 장비를 설치하거나 서비스하기 전에 설치, 작동 및 유지보수 지침을 철저히 읽으십시오.

  • 가스 공급: Ensure the gas supply is turned off before any installation or maintenance. All gas connections must be leak-tested.
  • 통풍: Proper venting is critical to prevent carbon monoxide poisoning. Ensure the vertical Category 1 B-vent kit is installed correctly and maintained.
  • 전기 연결: All electrical wiring must comply with local codes and be performed by a qualified electrician. Disconnect power before servicing.
  • 정리 : Maintain adequate clearances from combustible materials as specified in the installation instructions.
  • 전문적인 설치: Installation and service should be performed by a qualified installer, service agency, or gas supplier.

3. 제품 오버view

The Reznor UDXC-45 unit heater is engineered for durability and efficient heating. It features a robust design suitable for demanding environments.

Reznor UDXC-45 Unit Heater with key features listed

이미지: 앞면 view of the Reznor UDXC-45 unit heater highlighting standard features such as 83% AFUE efficiency and TCORE2 heat exchanger.

주요 특징:

  • 고성능: Rated for 45,000 BTU with an 83% thermal efficiency rating.
  • 내구성 있는 구조: Features a TCORE2 titanium-stabilized aluminized steel heat exchanger.
  • 고급 점화: Patented single-burner combustion with multi-try direct spark ignition and time lockout.
  • 사용자 인터페이스: Integrated circuit board with a 7-segment display for troubleshooting and status-indicating LED.
  • 조용한 작동: Low noise operation with vibration-isolated fan and venter motors.
  • 설치 유연성: Threaded-nut retainers at four suspension points for ceiling or wall mounting (mounting hardware sold separately).
  • 유지 보수 액세스: Hinged access door panel with a quarter-turn latch and external gas connection for ease of maintenance.
Icons representing scratch resistance, durable build, modern design, and quiet operation

Image: Visual representation of the heater's attributes including scratch resistance, durable build, modern design, and quiet operation.

4. 사양

Detailed technical specifications for the Reznor UDXC-45 unit heater.

Diagram showing dimensions of the 45,000 BTU Reznor heater

Image: Diagram illustrating the physical dimensions of the 45,000 BTU Reznor UDXC-45 heater.

사양
모델 번호UDXC-45
열 출력45,000 영국 열량 단위(BTU)
열 효율83%
연료 유형천연가스
가열 방식강제 공기
실내/실외 사용실내
폼 팩터천장 장착
제품 크기(D x W x H)29.75인치 x 27인치 x 13.75인치
속도의 수2

5. 설치

The Reznor UDXC-45 is designed for ceiling or wall mounting. A vertical Category 1 double wall B-vent kit is included for roof venting. Consult a qualified professional for installation to ensure compliance with all local codes and safety standards.

설치:

  • The unit features threaded-nut retainers at four suspension points for secure mounting.
  • Mounting hardware is sold separately and should be selected based on the specific installation environment and structural requirements.
  • Ensure the mounting location can support the weight of the unit and provides adequate clearance from combustible surfaces.
Reznor UDXC-45 heater installed on a ceiling in a garage

Image: A Reznor UDXC-45 heater mounted on a ceiling, demonstrating a typical installation in a garage or workshop setting.

환기:

The included vertical Category 1 double wall B-vent kit is essential for safely expelling combustion byproducts. Follow the kit's instructions and local codes for proper installation.

  • The kit typically includes components such as a Reznor CCI Vent Cap, Draft Hood Connector, Straight Pipes (12" and 24" lengths), Adjustable Elbows (60° and 90°), Roof Flashing, and a Storm Collar.
  • Ensure all vent connections are sealed properly to prevent leaks.
Components of a 4-inch diameter double wall B-vent kit

Image: Various components of a 4-inch diameter double wall B-vent kit, used for vertical venting applications.

6. 운영

Once properly installed and connected to the natural gas and electrical supplies, the Reznor UDXC-45 heater is ready for operation. This unit utilizes forced air for efficient heat distribution.

히터 시작하기:

  1. Ensure the gas supply valve to the heater is open.
  2. 장치의 전원을 켭니다.
  3. 온도 조절기를 원하는 온도로 설정하십시오. 히터가 점화 과정을 시작합니다.
  4. Observe the status-indicating LED and 7-segment display for operational status.

공기 순환:

The low static pressure axial fan and power venting system are designed to reduce heat loss and ensure effective air circulation throughout the heated space.

Diagram illustrating air circulation patterns from a unit heater

Image: A diagram showing the air circulation patterns generated by a unit heater, indicating effective heat distribution.

7. 유지관리

Regular maintenance ensures the longevity and efficient operation of your Reznor UDXC-45 heater. Always disconnect electrical power and turn off the gas supply before performing any maintenance.

  • 연례 검사: Have a qualified service technician inspect the heater annually, including the heat exchanger, burner, ignition system, and venting.
  • 청소: Keep the area around the heater clean and free of obstructions. Periodically clean the fan blades and motor to prevent dust buildup.
  • 환기 시스템 점검: Inspect the vent system for any signs of corrosion, blockages, or leaks. Ensure the vent cap is clear.
  • 열교환 기: The TCORE2 titanium-stabilized aluminized steel heat exchanger is designed for durability, but should be inspected for any signs of damage or wear during annual service.

8. 문제 해결

The Reznor UDXC-45 is equipped with an integrated circuit board and a 7-segment display for diagnostics, along with a status-indicating LED to assist in troubleshooting. Refer to the specific error codes displayed on the 7-segment display for detailed guidance.

일반적인 문제:

  • 열 없음 : Check if the thermostat is set correctly, the gas supply is open, and the electrical power is on. Look for error codes on the display.
  • Pilot Light/Ignition Failure: The multi-try direct spark ignition system will attempt to light the burner multiple times. If it fails, an error code will be displayed. This may indicate a gas supply issue or a problem with the ignition components.
  • 특이한 소음: While designed for quiet operation, any new or unusual noises should be investigated. This could indicate a fan issue or other mechanical problem.
  • Heater Cycles On/Off Frequently: This could be due to an improperly sized unit, thermostat placement, or airflow restrictions.

For persistent issues or complex problems, contact a qualified service technician.

9. 보증 및 지원

For warranty information, please refer to the documentation provided with your Reznor UDXC-45 unit heater or contact the manufacturer directly. Support for this product may also be available through the seller, 1HVAC. Keep your purchase receipt and model number (UDXC-45) handy when contacting support.

관련 문서 - UDXC-45

사전view 전기 및 가스 히터용 Reznor 천장 서스펜션 키트 설치 가이드
EHU 전기 히터 및 UDXC, UDX, UDZ 가스 히터와 호환되는 Reznor CK22 천장 서스펜션 키트의 설치 지침 및 구성품 세부 정보입니다. Reznor 히터를 안전하게 설치하는 방법을 알아보세요.
사전view 레즈너 가스 변환 키트를 이용한 가스식 유닛 히터 설치
본 문서에서는 UBX, UBXC, UBZ, UDX, UDXC, UDZ, UDAP, UDAS, UDBP, UDBS를 포함한 다양한 가스식 유닛 히터 모델용 Reznor 가스 변환 키트 설치 지침을 제공합니다. 천연가스와 프로판 가스 간 변환 및 고지대 설치를 위한 구성 요소 선택, 안전 예방 조치, 설치 단계를 자세히 설명합니다.
사전view 전기 및 가스 히터용 Reznor 천장 서스펜션 키트 설치(옵션 CK22)
EHU, UDX, UDXC, UDZ 전기 및 가스 히터용으로 설계된 Reznor CK22 천장 현수 키트 설치 안내서입니다. 키트 구성품과 설치 단계가 포함되어 있습니다.
사전view Reznor Unit Heater Venting Instructions for UBX and UDX Models
Comprehensive venting instructions for Reznor UBX (Standard Power Vent Blower Type) and UDX (Standard Power Vent Fan Type) unit heaters. Covers general information, safety precautions, venting requirements, condensation mitigation, vent terminal specifications, and installation procedures for both commercial/industrial and residential applications.
사전view 가스 연소 유닛 히터용 Reznor 수직 루버 키트 설치 가이드(OPT-CD1)
가스 연소식 유닛 히터(UBX, UBXC, UBZ, UDX, UDXC, UDZ, UEZ 모델)용으로 설계된 Reznor OPT-CD1 수직 루버 키트 설치 설명서입니다. 구성품 목록과 단계별 조립 가이드가 포함되어 있습니다.
사전view Reznor 릴레이 키트 다중 장치 제어용 설치 가이드(CL31/CL32)
Reznor CL31 및 CL32 릴레이 키트의 종합 설치 가이드로, 다양한 Reznor 전기 및 가스 히터의 다중 장치 제어를 가능하게 합니다. 구성품 목록, 자세한 설치 단계 및 배선 사양이 포함되어 있습니다.