Hochiki RPV-AAW20

Hochiki Type P1 Fire Alarm Panel RPV-AAW20 User Manual

모델: RPV-AAW20 | 브랜드: 호치키 주식회사

Approval No.: 28-3

1. 서론

This manual provides comprehensive instructions for the safe and effective use of the Hochiki Type P1 Fire Alarm Panel, model RPV-AAW20. This device is a 20-line wall-mounted fire alarm control panel designed for reliable fire detection and alarm management. Please read this manual thoroughly before installation, operation, or maintenance to ensure proper functionality and safety.

2. 안전 정보

중요 안전 지침:

  • Installation and servicing must be performed by qualified personnel only, in accordance with all local and national electrical and fire safety codes.
  • Disconnect all power sources before performing any maintenance or service on the panel.
  • Do not operate the panel with damaged components or wiring.
  • Ensure the panel is securely mounted to a wall in a suitable environment, away from excessive moisture, dust, or extreme temperatures.
  • Regularly test the system as recommended by local regulations and this manual to ensure proper operation.

3. 제품 오버view

The Hochiki RPV-AAW20 is a Type P1 fire alarm control panel capable of monitoring up to 20 fire detection zones. It features a clear display for status indication, integrated controls for alarm management, and a communication function.

Hochiki Type P1 Fire Alarm Panel RPV-AAW20

그림 1: 앞쪽 view of the Hochiki Type P1 Fire Alarm Panel RPV-AAW20. The panel features a main display area for fire alarm status, individual zone indicators, a microphone for communication, and buttons for sound stop and fault confirmation.

주요 구성 요소:

  • Fire Alarm Control Panel (火災受信盤): Main display and indicator section.
  • Fire Indicator (火災): Illuminates when a fire alarm is detected.
  • Microphone (マイク): Used for communication functions.
  • Listen to Information (状況に応じた情報を聞く): Button to access status information or voice guidance.
  • Determine/Confirm (断定): Button for confirming events or system status.
  • Sound Stop (音響停止): Button to silence the local panel's alarm sound.
  • Area (Bell) Temporary Stop (地区(ベル)一時停止): Button to temporarily silence building bells/sirens in a specific area.

4. 설정

The RPV-AAW20 fire alarm panel requires professional installation. This section provides a general overview; refer to the detailed installation manual provided with the product for specific wiring diagrams and procedures.

4.1 장착

  • Select a suitable wall location that is easily accessible, visible, and protected from environmental hazards.
  • Ensure the mounting surface can support the weight of the panel.
  • Securely mount the panel using appropriate fasteners.

4.2 배선

  • Connect the main power supply according to local electrical codes.
  • Connect fire detection zones (detectors, manual call points) to the designated terminals.
  • Connect alarm notification appliances (bells, strobes) and auxiliary devices.
  • Ensure all wiring is correctly terminated and secured.

4.3 초기 전원 켜기 및 테스트

  • After all connections are made, apply power to the panel.
  • Observe the panel for initial self-tests and status indicators.
  • Perform a comprehensive system test to verify proper operation of all detectors, notification appliances, and control functions.

5. 사용 설명서

5.1 정상 작동

In normal operation, the panel's status indicators should show no alarms or faults. The power indicator should be illuminated.

5.2 When a Fire Alarm Sounds (火災警報音が困ったとき)

  1. Identify the Alarm: The 'Fire' indicator will illuminate, and the panel will sound an alarm. Check the zone indicators to identify the location of the alarm.
  2. 상황을 평가하세요: Visually inspect the indicated area if safe to do so.
  3. Silence Local Panel Sound: 를 누르세요 Sound Stop (音響停止) button to silence the local panel's alarm sound. The 'Fire' indicator will remain illuminated until the alarm condition is cleared.
  4. Silence Building Bells (Temporarily): 필요한 경우 Area (Bell) Temporary Stop (地区(ベル)一時停止) button to temporarily silence the building's bells/sirens in the affected area.
  5. Contact Emergency Services: Immediately contact local fire emergency services (e.g., 119 in Japan) and provide them with the alarm location and any relevant information.
  6. 대피: Follow established evacuation procedures.

5.3 Using the Communication Function (電話ですと思ったとき)

The panel is equipped with a microphone for communication purposes, potentially for intercom or emergency communication with specific points in the building.

  • To initiate communication, activate the relevant function (refer to the detailed operational guide for specific steps).
  • Speak clearly into the Microphone (マイク).

5.4 Listening to Information (状況に応じた情報を聞く)

를 누르세요 Listen to Information (状況に応じた情報を聞く) button to receive status updates or voice guidance from the panel regarding its current state or an event.

6. 유지관리

Regular maintenance is crucial for the reliable operation of your fire alarm system. It should be performed by qualified technicians.

6.1 일일 점검

  • Verify that the 'Power' indicator is illuminated.
  • Check for any fault indicators or unusual sounds.

6.2 주기적 테스트

  • Conduct regular tests of detectors, manual call points, and alarm notification appliances as per local regulations (e.g., monthly, quarterly, annually).
  • Test the panel's battery backup system to ensure it functions during power outag에스.

6.3 청소

  • Gently wipe the exterior of the panel with a soft, dry cloth.
  • 연마성 세척제나 용제를 사용하지 마십시오.

7. 문제 해결

This section addresses common issues you might encounter with the RPV-AAW20 panel. For complex problems, always contact a qualified service technician.

7.1 When a Fault Sound Occurs (障害音質が困ったとき)

If the panel emits a fault sound or displays a fault indicator:

  • 오류 코드 확인: Look for any displayed error codes on the panel. Refer to the detailed product manual for a list of error codes and their meanings.
  • 오류를 찾아내십시오: The panel will typically indicate the type of fault (e.g., power failure, zone fault, communication error).
  • 서비스 문의: For most fault conditions, especially those involving internal components or wiring, contact a qualified Hochiki service technician. Do not attempt repairs yourself unless specifically instructed and qualified.
  • Maintenance Switch: If instructed by a technician, you may need to access the maintenance switch by removing its cover. This should only be done under professional guidance.

7.2 Panel Not Powering On

  • Check the main power supply to the panel.
  • Verify that the circuit breaker for the panel is not tripped.
  • Ensure internal battery connections are secure (if applicable).

8. 사양

특징사양
모델RPV-AAW20
유형P1 Fire Alarm Panel
줄의 수20
설치벽걸이형
제조업체호치키 주식회사
승인 번호28-3
첫 번째 가능한 날짜2024/06/10

9. 보증 및 지원

For warranty information, technical support, or service requests, please contact your authorized Hochiki dealer or the Hochiki Corporation directly. Keep your purchase receipt and model number (RPV-AAW20) readily available when contacting support.

관련 문서 - RPV-AAW20

사전view FNV 25 / FNV 50 / FNV 100 음성 대피 인터페이스 시스템 설치 지침
호치키 FNV 25, FNV 50, FNV 100 음성 대피 인터페이스 시스템의 종합 설치 가이드입니다. 시스템 전반에 걸친 내용을 다룹니다.view설치 절차, 배선 세부 정보, 단자 명칭, 작동 방식, 사양, 스위치 설정 및 문제 해결 방법.
사전view Hochiki FireNET Graphix: 설치 및 프로그래밍 매뉴얼
Hochiki FireNET graphix 화재 경보 시스템 그래픽 소프트웨어의 설치, 구성 및 프로그래밍에 대한 포괄적인 가이드입니다. 시스템 전반에 걸쳐 다룹니다.view, 하드웨어 설치, 소프트웨어 설정, 애플리케이션 실행, 디자인 도구 및 유틸리티.
사전view FN-1127 제어판 및 FN-LCD-S 표시기용 Hochiki FireNET PLUS 작동 지침
호치키 파이어넷 플러스 FN-1127 제어 패널 및 FN-LCD-S 경보기에 대한 종합적인 작동 설명서로, 화재 및 고장 상황, 버튼 기능, 퓨즈 교체, 배터리 유지 관리 및 SOM-R 릴리스에 대한 자세한 내용을 담고 있습니다.asing 함수.
사전view 호치키 화재 경보 장치 데이트: Fire Trade Supplies의 가이드
ATJ-EN 모델을 포함한 호치키 화재 경보 장치의 일련번호와 제조 코드를 사용하여 날짜를 확인하는 방법을 알아보세요. Fire Trade Supplies의 연락처도 확인해 보세요.
사전view 호치키 제품 가이드 ISS30:MAR24 - 화재 감지 시스템 및 솔루션
주소 지정 가능, 기존, 무선 및 무선을 포함한 고급 화재 감지 시스템 범위를 자세히 설명하는 Hochiki의 포괄적인 제품 가이드amp링 테크놀로지. 호치키의 화재 안전 혁신에 대한 헌신에 대해 알아보세요.
사전view Hochiki HFP AP 단일/이중 루프 제어 패널 범위 제품 설명서
호치키 HFP AP 단일/이중 루프 제어 패널 제품군에 대한 포괄적인 제품 설명서로, 설치, 작동 및 프로그래밍 방법을 자세히 설명합니다. 기술 사양, 안전 지침, 케이블 연결, 전면 패널 제어 및 구성 옵션에 대한 내용을 다룹니다.