토소트 60,00BTU-50ft

TOSOT 60,000 BTU (5 Ton) Ducted Central Air Conditioner Heat Pump System

모델: 60,00BTU-50ft

상표: 토솟

1. 서론

This manual provides comprehensive instructions for the installation, operation, and maintenance of your TOSOT 60,000 BTU (5 Ton) Ducted Central Air Conditioner Heat Pump System. Please read this manual thoroughly before installation and use to ensure proper function and safety. Keep this manual for future reference.

중요한 안전 정보

  • 전문 설치 필요: This system requires installation by a certified HVAC technician for optimal performance and safety. DIY installation is not recommended.
  • 전기 안전: Ensure all electrical connections comply with local codes and standards. Disconnect power before any service or maintenance.
  • 냉매 취급: This system uses R-32 refrigerant. Only qualified personnel should handle refrigerant.
  • 모든 경고 사항을 읽으십시오: Pay close attention to all warning labels on the unit and throughout this manual.

2. 제품 오버view

The TOSOT 60,000 BTU (5 Ton) Ducted Central Air Conditioner Heat Pump System is an inverter split system designed for efficient heating and cooling. It features advanced technology for reliable operation in various climates.

포함된 구성 요소

  • 실외 콘덴서 유닛
  • 실내 공기 조절 장치
  • 50피트 구리 배관 세트
  • Installation Kit (includes sealing gum, wall cap, wall sleeve, tapes, and user manual)
TOSOT 60,000 BTU Ducted Central Air Conditioner Heat Pump System with Outdoor Condenser, Indoor Air Handler, and 50-foot Copper Line Set

Figure 2.1: Complete TOSOT Central Air Conditioner Heat Pump System with included components.

비디오 2.1: 끝view of the TOSOT Central Air Conditioner Heat Pump System, highlighting its main units and features.

3. 주요 특징

3.1. UltraCool & UltraHeat Technology

This system provides efficient heating and cooling across a wide temperature range, from -22℉ to 130℉, ensuring comfort in extreme conditions.

Graph illustrating UltraCool and UltraHeat performance across extreme temperatures from -22°F to 130°F

Figure 3.1: Performance capabilities of UltraCool and UltraHeat technology in varying outdoor temperatures.

3.2. Self-Developed Inverter Compressor

The system utilizes a triple-cylinder two-stage rotary compressor with enhanced vapor injection technology. This design optimizes low-temperature heating, maintaining 100% heating capacity at -5℉ and 100% cooling performance at 115℉.

Diagram showing the DC Inverter Compressor with specifications for SEER2, HSPF2, efficiency, and noise level

Figure 3.2: Details of the DC Inverter Compressor, highlighting its efficiency and low noise operation.

Video 3.1: Demonstration of the Central AC Heat Pump with Inverter Technology, showcasing는 운영상의 이점입니다.

Video 3.2: Visual explanation of the Central AC Split System Heat Pump with Inverter, detailing its components and function.

3.3. 에너지 효율성

With ratings up to 18.5 SEER2 and 10.5 HSPF2, this system offers significant energy savings. Inverter technology can provide up to 30% more energy savings compared to non-inverter systems with the same SEER2 rating. It is Energy Star certified and may qualify for federal tax credits.

TOSOT outdoor condenser unit with Energy Star, ETL, AHRI Certified, and NEEP logos, indicating superior energy efficiency

Figure 3.3: Energy Star and other certifications for the TOSOT Heat Pump System.

3.4. Upgraded Condenser Design

The slim design of the outdoor condenser unit requires less space, making it suitable for constricted areas. Its side discharge design minimizes debris accumulation and keeps noise levels below 63 dB.

Comparison of TOSOT APEX Condenser (slim, side discharge) with Traditional Condenser (large, top discharge)

Figure 3.4: Comparison of TOSOT APEX Condenser design with traditional condensers.

3.5. High Static Pressure Design

The TOSOT unitary central AC adapts to actual static pressure, making it ideal for areas requiring long-distance airflow. It offers eight adjustable fan speeds to meet the needs of various living spaces.

Diagram showing high static pressure fan features: 8 adjustable fan speeds, adapts to actual static pressure, suitable for diverse living spaces

Figure 3.5: Benefits of the High Static Pressure Fan for optimized airflow.

3.6. Multipositional Air Handler

The indoor air handler unit can be installed horizontally or vertically, providing flexible installation options for basements, attics, and both residential and commercial spaces.

Illustrations showing horizontal and vertical installation options for the TOSOT indoor air handler unit

Figure 3.6: Flexible installation configurations for the indoor air handler.

4. 사양

특징사양
상표토솟
모델60,00BTU-50ft
용량5톤(60,000 BTU)
냉각 전력53,000 영국 열 단위
계절별 에너지 효율 비율(SEER2)18.5
난방 계절 성능 계수(HSPF2)10.5
소음 수준63 Decibels (Outdoor Condenser)
작동 온도 범위-22℉ ~ 130℉
압축기 유형Inverter, Triple-Cylinder Two-Stage 로터리
냉각제R-32
권tage230 볼트
왓tage16,120 와트
Outdoor Condenser Dimensions (D x W x H)13.4인치 x 35.4인치 x 49.6인치
Indoor Air Handler Dimensions (D x W x H)21.3인치 x 24.8인치 x 52.0인치
품목 무게241파운드
바닥 면적 적용최대 3000평방피트
라인 세트 길이50 feet (Copper)
인증Energy Star, ETL, AHRI Certified

5. 설정 및 설치

The TOSOT Central Air Conditioner Heat Pump System is a complex appliance that requires professional installation. Attempting to install this unit without proper certification and tools can lead to serious injury, property damage, and void the product warranty.

5.1. 설치 전 고려 사항

  • 위치: Choose appropriate locations for both the outdoor condenser and indoor air handler, considering airflow, noise, and accessibility for maintenance. The multipositional air handler allows for vertical or horizontal installation.
  • 전기 요구 사항: Ensure the electrical supply meets the 230V requirement and is properly grounded.
  • 덕트워크: Verify existing ductwork is compatible and in good condition for efficient air distribution. The high static pressure design is suitable for long-distance airflow.
  • 온도 조절기 : This system is compatible with universal 24V thermostats (not included).
Diagram showing a 24V thermostat connected to the central AC system

Figure 5.1: Universal 24V thermostat compatibility.

5.2. Professional Installation Steps (Summary)

  1. Mount the indoor air handler in the chosen vertical or horizontal position.
  2. Position the outdoor condenser unit, ensuring adequate clearance for airflow.
  3. Connect the 50-foot copper line set between the indoor and outdoor units.
  4. Perform all necessary electrical wiring connections.
  5. Connect the thermostat wiring.
  6. Evacuate the refrigerant lines and charge the system with R-32 refrigerant.
  7. Test the system for proper operation, including airflow and temperature control.
Image emphasizing professional installation for the central air conditioning system

Figure 5.2: Professional installation is crucial for system integrity and safety.

6. 사용 설명서

Once professionally installed, your TOSOT Heat Pump System is controlled via a compatible 24V thermostat. Refer to your thermostat's user manual for specific programming and operation details.

6.1. 기본 동작

  • 전원 켜기/끄기: Use your thermostat to turn the system on or off.
  • 모드 선택: Select desired operating mode (Cool, Heat, Fan, Auto) on your thermostat.
  • 온도 설정: 온도 조절 장치를 이용해 원하는 온도를 조절하세요.

6.2. 팬 속도 조절

The system features eight adjustable fan speeds. Your installer can configure these settings to optimize airflow and comfort for your specific ductwork and living space. Consult your installer or thermostat manual for how to adjust fan speeds if accessible to the user.

7. 유지관리

Regular maintenance is essential to ensure the longevity and efficient operation of your TOSOT Heat Pump System. It is recommended to schedule annual professional maintenance.

7.1. 필터 교체

Regularly check and replace the air filter in your indoor air handler. A dirty filter restricts airflow and reduces efficiency. The recommended filter size is 20x23 inches, though some documentation may incorrectly state 20x20 inches. Verify the actual size of your installed filter.

7.2. Outdoor Condenser Cleaning

Keep the area around the outdoor condenser unit clear of debris, leaves, and vegetation to ensure proper airflow. The side discharge design helps minimize accumulation, but periodic inspection is still advised.

7.3. 전문 서비스

Schedule annual maintenance with a certified HVAC technician. This includes checking refrigerant levels, inspecting electrical components, cleaning coils, and verifying overall system performance.

8. 문제 해결

If you experience issues with your system, perform the following basic checks before contacting a service technician:

  • 전원 없음: Check the circuit breaker for the unit. Ensure the thermostat is set to the desired mode and temperature.
  • 냉방/난방이 충분하지 않음: Verify the thermostat settings. Check if the air filter is clean. Ensure outdoor unit is free of obstructions.
  • 특이한 소음: 작동 중 약간의 소음은 정상입니다. 크거나 이상한 소음이 들리면 기술자에게 문의하십시오.
  • 물 누출: 응축수 배수관에 막힘이 있는지 확인하십시오.

For any persistent issues or complex problems, contact a certified HVAC technician for diagnosis and repair.

9. 보증 및 지원

9.1. 보증 정보

The TOSOT 60,000 BTU Ducted Central Air Conditioner Heat Pump System comes with a XNUMX년 보증. Please retain your proof of purchase and installation records for warranty claims. The warranty covers defects in materials and workmanship under normal use and service.

For specific terms and conditions of the warranty, refer to the warranty card included with your product or contact TOSOT customer support.

9.2. 고객 지원

For technical assistance, troubleshooting, or warranty inquiries, please contact TOSOT customer support:

  • Web대지: [Insert TOSOT Support Web사이트 [여기]
  • 핸드폰: [Insert TOSOT Support Phone Number Here]
  • 이메일: [Insert TOSOT Support Email Here]

When contacting support, please have your model number (60,00BTU-50ft) and date of purchase readily available.

관련 문서 - 60,00BTU-50ft

사전view 토쏘 분리형 에어컨 사용 설명서
토쏘 분리형 에어컨(TWH09AT19A6A 및 기타 TWH 시리즈 모델 포함)의 안전 수칙, 설치, 작동, 유지 관리 및 문제 해결 방법을 자세히 설명하는 종합 사용 설명서입니다.
사전view TOSOT 스플릿형 에어컨 사양 및 치수
TOSOT 스플릿형 에어컨 모델 TM18HMO, TM24HMO, TM30HMO, TM36HMO, TM42HMO에 대한 자세한 기술 사양, 성능 데이터 및 물리적 치수입니다.
사전view 토소트 RV 에어컨 설치 가이드
TOSOT RV 에어컨 설치에 대한 단계별 지침입니다. 밀봉, 본체 장착, 덕트 플레이트 설치, 천장 프레임, 배선 및 그릴 조립 과정을 다룹니다.
사전view 토쏘 8,000 BTU 창문형 에어컨 사용 설명서 | 설치, 작동 및 문제 해결
토소트 8,000 BTU 창문형 에어컨(모델 GJC08BU-A6NRNJ2A)의 종합 사용 설명서입니다. 설치, 작동, 리모컨 사용, 청소, 유지 보수, 문제 해결 및 안전 지침을 다룹니다.
사전view TOSOT Clivia Deluxe TH-SCD 에어컨 사용 설명서
TOSOT Clivia Deluxe TH-SCD 시리즈 에어컨의 기능, 작동, 사양, 유지 관리 및 안전에 대한 포괄적인 사용 설명서입니다. R32 냉매 정보와 WiFi 연결 정보가 포함되어 있습니다.
사전view 토쏘 분리형 스탠드형 에어컨 사용 설명서
토쏘 분리형 스탠드형 에어컨의 설치, 작동, 유지 관리, 안전 수칙 및 문제 해결 방법을 자세히 설명하는 사용자 설명서입니다. SU-COSMO36FS/I 모델에 대한 내용도 포함되어 있습니다.