1. 서론
This manual provides essential information for the installation, operation, and maintenance of your ABUS AZAA10000 Terxon SX Alarm Control Panel. Please read these instructions carefully before attempting to install or operate the system to ensure proper functionality and safety.
The ABUS AZAA10000 Terxon SX is a wired alarm control panel designed to provide reliable security for your premises. It integrates various security components to detect intrusions and alert users.
2. 안전 정보
- 전기 안전: Installation and wiring should only be performed by qualified personnel. Disconnect power before servicing the unit.
- 배터리 취급: The system uses a lead-acid battery. Handle with care. Do not short-circuit, puncture, or expose to extreme temperatures. Dispose of batteries according to local regulations.
- 환경 조건: Install the control panel in a dry, protected area, away from direct sunlight, extreme temperatures, and high humidity.
- 허가된 사용: Use the system only for its intended purpose as an alarm control panel.
3. 패키지 내용
패키지에 모든 구성 요소가 들어 있는지 확인하세요.
- ABUS AZAA10000 Terxon SX 경보 제어판
- Keypad (LCD control panel)
- Installation hardware (screws, anchors)
- 사용 설명서 (본 문서)
- 전원 케이블/어댑터
- Lead-acid battery (may be pre-installed or separate)
4. 제품 오버view
The ABUS AZAA10000 Terxon SX system consists of a main control panel unit and a separate LCD keypad for user interaction.

그림 1: ABUS AZAA10000 Terxon SX Alarm Control Panel (right) and LCD Keypad (left). The control panel houses the main electronics and battery, while the keypad provides the interface for arming, disarming, and system configuration.

그림 2: 또 다른 view of the ABUS AZAA10000 Terxon SX Alarm Control Panel and LCD Keypad, highlighting the compact design of the keypad for discreet placement.
4.1 제어판
The main control panel unit is the central processing unit of the alarm system. It manages all connected sensors, communicates with the keypad, and triggers alarms. It typically includes terminals for wired connections, a power input, and a compartment for the backup battery.
4.2 LCD 키패드
The LCD keypad serves as the primary user interface. It features a display for status messages, a numeric keypad for entering codes, and function buttons for arming, disarming, and accessing system menus. Compatible devices include the LCD control panel, relay board, and optional plug-in relay module.
5. 설정 및 설치
Proper setup and installation are crucial for the reliable operation of your alarm system. It is recommended that installation be performed by a certified security technician.
5.1 제어 패널 장착
- 위치 선택: Choose a secure, discreet, and centrally located area, preferably indoors, away from extreme temperatures and moisture. Ensure it is accessible for maintenance but not easily tamp로 이루어짐.
- 안전한 장착: Use appropriate screws and anchors (type: screw-in) to firmly attach the control panel to a wall. Ensure the mounting surface can support the unit's weight (2.8 kg).
5.2 키패드 장착
- 위치 선택: Install the keypad near the main entry/exit point of the protected area, at a convenient height for all users.
- 안전한 장착: Mount the keypad securely to the wall using the provided hardware.
5.3 배선 연결
The ABUS AZAA10000 Terxon SX is a wired system. All connections (sensors, sirens, power, keypad) must be made using appropriate wiring. Refer to the detailed wiring diagrams provided in the separate installation guide for specific terminal connections.
- 전원 연결: Connect the control panel to a 230 Volt AC power source.
- 배터리 연결: Connect the lead-acid backup battery to the designated terminals inside the control panel.
- 키패드 연결: Connect the keypad to the control panel using the specified wired connection.
- 센서 연결: Connect all wired sensors (e.g., motion detectors, door/window contacts) to the appropriate zone inputs on the control panel.
- Siren/Strobe Connections: Connect external sirens and strobe lights to the alarm outputs.
5.4 초기 전원 켜기 및 구성
- 전원 적용: Once all wiring is complete and checked, connect the main power supply.
- 시스템 초기화: The system will perform a self-test. Follow the on-screen prompts on the keypad.
- Program Master Code: Set a unique master user code. This code is essential for system programming and advanced functions.
- Zone Programming: Configure each connected sensor zone according to its type (e.g., entry/exit, interior, 24-hour).
- 사용자 코드: Create additional user codes for family members or authorized personnel.
6. 사용 설명서
This section covers the basic daily operation of your ABUS AZAA10000 Terxon SX Alarm Control Panel.
6.1 시스템 준비
- Full Arming (Away Mode): Ensures all zones are active. Enter your user code and press the "Arm" button (or equivalent). The system will provide an exit delay.
- Partial Arming (Stay Mode): Activates perimeter zones while allowing movement within interior zones. Enter your user code and press the "Stay" or "Partial Arm" button.
6.2 시스템 해제
To disarm the system, enter your user code when prompted (e.g., upon entry during the entry delay) or press the "Disarm" button (or equivalent) and then enter your code.
6.3 Alarm Events
When an alarm is triggered, the system will activate sirens (audio) and potentially strobe lights (visual). The keypad display will indicate the triggered zone. To silence the alarm, disarm the system using your user code.
6.4 시스템 상태
The LCD keypad displays the current system status, including armed/disarmed state, open zones, and any system faults (e.g., low battery, communication errors).
7. 유지관리
정기적인 유지보수는 경보 시스템의 수명과 신뢰성을 보장합니다.
- 배터리 점검: The lead-acid backup battery should be checked periodically (e.g., annually) and replaced every 3-5 years, or when the system indicates a low battery fault.
- 청소: Gently wipe the keypad and control panel housing with a soft, dry cloth. Do not use abrasive cleaners or solvents.
- 센서 테스트: Periodically test all connected sensors (e.g., motion detectors, door/window contacts) to ensure they are functioning correctly.
- 소프트웨어 업데이트: While specific software update information is not available, it is good practice to consult with your installer or ABUS support for any recommended firmware updates.
8. 문제 해결
This section addresses common issues you might encounter with your ABUS AZAA10000 Terxon SX Alarm Control Panel.
| 문제 | 가능한 원인 | 해결책 |
|---|---|---|
| 시스템이 작동하지 않습니다 | Open zone (door/window open), system fault, incorrect user code. | Check all doors and windows. Verify system status on keypad for faults. Re-enter user code carefully. |
| 허위 경보 | Faulty sensor, improper zone programming, environmental factors (pets, drafts). | Identify the triggered zone. Inspect the sensor for damage. Review zone programming. Adjust sensor sensitivity if applicable. |
| 키패드가 응답하지 않습니다 | Loss of power, keypad wiring issue, keypad malfunction. | Check main power and backup battery. Inspect keypad wiring connections. If problem persists, contact support. |
| 배터리 부족 경고 | Backup battery needs replacement or is not charging. | Allow time for the battery to charge. If warning persists, replace the lead-acid backup battery. |
For issues not listed here or if troubleshooting steps do not resolve the problem, please contact ABUS technical support or your certified installer.
9. 사양
| 특징 | 세부 사항 |
|---|---|
| 상표 | 학대 |
| 모델 번호 | AZAA10000 |
| 색상 | 화이트-417 |
| 연결 기술 | 열광한 |
| 전원 | Battery Powered (with AC input) |
| 배터리 구성 | 납산 |
| 권tage | 230 볼트 |
| 품목 무게 | 2.8 킬로그램 |
| 치수(길이 x 너비 x 높이) | 8.7 x 25 x 23.9 센티미터 |
| 설치 유형 | 스크류 인 |
| 경고 유형 | 오디오 및 모션 |
| 호환 장치 | LCD control panel, relay board, optional plug-in relay module |
10. 보증 및 지원
ABUS provides a warranty period of at least 2년 after purchase for this product, ensuring proper functionality and protection against defects.
Spare parts availability is guaranteed for 1년.
For technical assistance, warranty claims, or further information, please contact your authorized ABUS dealer or visit the official ABUS web지원 리소스 사이트.