OWON SDS1102

OWON SDS1102 디지털 저장 오실로스코프 사용자 설명서

모델: SDS1102

1. 서론

This manual provides detailed instructions for the operation and maintenance of the OWON SDS1102 Digital Storage Oscilloscope. The SDS1102 is a 2-channel desktop oscilloscope offering a 100MHz bandwidth and a 1GS/s real-time sample rate. It features a 7-inch high-resolution LCD and supports SCPI commands and LabVIEW for advanced control and data acquisition. Please read this manual thoroughly before using the device to ensure proper and safe operation.

2. 안전 정보

To prevent electric shock or personal injury, and to avoid damage to the oscilloscope or connected equipment, observe the following safety precautions:

3. 패키지 내용

Verify that all items listed below are included in your package. If any items are missing or damaged, please contact your distributor.

OWON SDS1102 Oscilloscope and accessories

그림 3.1: OWON SDS1102 Digital Storage Oscilloscope with included accessories. The image displays the main oscilloscope unit, two oscilloscope probes, a power cord, a USB cable, and a software CD.

4. 제품 오버view

The OWON SDS1102 is designed for precise waveform analysis with its intuitive interface and robust features.

4.1 주요 특징

4.2 전면 패널

Front panel of OWON SDS1102 Oscilloscope

그림 4.1: 앞쪽 view of the OWON SDS1102 Oscilloscope highlighting its display and controls. The image shows the 7-inch LCD screen, control knobs, function buttons, and input connectors for channels 1 and 2. Key specifications like 1GS/s Sample rate, 10K Record Length, 2-Channel, 100 MHz Bandwidth, and 7 inch high resolution LCD are overlaid.

The front panel includes the 7-inch LCD display, various control buttons, rotary knobs for horizontal and vertical adjustments, trigger controls, and the input connectors for Channel 1 (CH1) and Channel 2 (CH2). A USB host port is conveniently located on the front for data storage and firmware updates.

Front-sided USB port on OWON SDS1102 Oscilloscope

그림 4.2: Detail of the front-sided USB port. This image emphasizes the USB port on the front panel, indicating its use for saving data (waveform records) and its capacity for up to 10K samp링 포인트.

4.3 물리적 치수

Dimensions of OWON SDS1102 Oscilloscope

그림 4.3: Physical dimensions and weight of the SDS1102. The image shows the oscilloscope with its dimensions: 11.85 inches (301mm) width, 5.98 inches (152mm) height, and 2.75 inches (70mm) thickness. The total weight is 1.1 kg. It also highlights the ultra-thin design and the side-mounted power socket.

The SDS1102 features an ultra-thin design, measuring 301mm (width) x 152mm (height) x 70mm (thickness) and weighing approximately 1.1 kg, making it highly portable and space-efficient for desktop use.

4.4 디스플레이 인터페이스

7-inch LCD display of OWON SDS1102 Oscilloscope

그림 4.4: The 7-inch color LCD display. This image focuses on the oscilloscope's 7-inch color LCD screen, emphasizing its 800 x 480 pixel resolution for clear and concise waveform readings.

The 7-inch (800x480 pixels) color LCD provides a clear and detailed display of waveforms and measurement parameters. The display grid is 8x12, offering ample space for waveform visualization.

5. 설정

5.1 전원 연결

  1. 오실로스코프의 전원 스위치가 OFF 위치에 있는지 확인하세요.
  2. Connect the provided power cord to the power input socket on the side of the oscilloscope.
  3. Plug the other end of the power cord into a grounded AC power outlet (100V-240V AC, 50/60Hz).

5.2 프로브 연결

  1. Connect the BNC connector of the oscilloscope probe to the CH1 or CH2 input connector on the front panel.
  2. 프로브가 제자리에 단단히 고정되었는지 확인하십시오.
  3. 프로브 접지 클립을 회로의 접지 지점에 연결하십시오.
  4. Set the probe attenuation switch (usually on the probe itself) to the desired setting (e.g., 1X or 10X). Remember to match this setting in the oscilloscope's channel menu for accurate readings.

5.3 초기 전원 켜기

After connecting power and probes, press the power button on the front panel to turn on the oscilloscope. The device will perform a self-test and display the main waveform interface.

6. 사용 설명서

6.1 기본 파형 표시

Use the vertical (VOLTS/DIV) and horizontal (SEC/DIV) knobs to adjust the scale of the displayed waveform. The position knobs allow you to move the waveform vertically and horizontally on the screen.

6.2 트리거링

The trigger system stabilizes repetitive waveforms and captures single-shot events. Adjust the trigger level and mode using the dedicated trigger controls on the front panel to achieve a stable display.

6.3 Cursor Measurements

The SDS1102 supports cursor measurements for precise analysis of waveform parameters.

Cursor measurement display on OWON SDS1102 Oscilloscope

그림 6.1: Example of cursor measurements. This image shows the oscilloscope display with two vertical cursors (A and B) placed on a sine wave. The measurement results, including time difference (Δx) and voltage difference (Δy), are displayed on the screen.

To use cursor measurements:

  1. 를 누르세요 커서 단추.
  2. Select the desired cursor type (e.g., Voltage, Time, Track) from the menu.
  3. Use the multipurpose knob to position the cursors on the waveform.
  4. The measured values (e.g., ΔV, ΔT) will be displayed on the screen.

6.4 Automatic Measurements

The oscilloscope offers 30 types of automatic measurements, providing quick and accurate parameter readings.

Automatic measurement display on OWON SDS1102 Oscilloscope

그림 6.2: Automatic measurement results. This image displays a comprehensive list of automatic measurements for a waveform, including Max, Min, PK-PK, Vpp, Mean, RMS, Cycle RMS, Rise Time, Fall Time, Frequency, Period, Duty Cycle, and more.

To access automatic measurements:

  1. 를 누르세요 측정하다 단추.
  2. Select the desired measurement type from the menu.
  3. The results will be displayed on the screen.

6.5 파형 저장 및 불러오기

The SDS1102 allows for storing and recalling waveforms. You can save waveforms to the internal memory or to a USB flash drive connected to the front-sided USB port.

Waveform storage menu on OWON SDS1102 Oscilloscope

그림 6.3: Waveform storage menu. This image shows the oscilloscope's menu for saving and recalling waveforms, with options to select different waveform slots (Wave 8 to Wave 15) and to save or recall the selected waveform.

6.6 PC Communication (SCPI and LabVIEW)

The SDS1102 supports communication with a host computer via USB, enabling remote control using SCPI commands and integration with LabVIEW for advanced data analysis and automation.

OWON SDS1102 Oscilloscope connected to a laptop

그림 6.4: Oscilloscope connected to a laptop for PC communication. The image shows the OWON SDS1102 oscilloscope connected to a laptop via a USB cable, demonstrating its capability for communication and remote control using SCPI and LabVIEW.

To establish PC communication:

  1. Install the necessary drivers and software (e.g., LabVIEW drivers, SCPI command interface) on your computer.
  2. Connect the oscilloscope to your computer using the provided USB cable.
  3. Refer to the OWON website or software documentation for detailed instructions on using SCPI commands or LabVIEW 완성.

7. 유지관리

7.1 Cleaning the Oscilloscope

오실로스코프의 성능과 외관을 유지하려면 다음 사항을 준수하십시오.

7.2 펌웨어 업데이트

Firmware updates may be released periodically to improve performance or add new features. These updates can typically be performed via the front-sided USB port using a USB flash drive.

8. 문제 해결

이 섹션에서는 일반적으로 발생할 수 있는 문제에 대한 해결책을 제공합니다.

문제가능한 원인해결책
파형이 표시되지 않습니다
  • Probe not connected or faulty
  • Incorrect vertical/horizontal scale
  • Trigger not set correctly
  • Input signal too small or too large
  • Check probe connection and integrity.
  • Adjust VOLTS/DIV and SEC/DIV knobs.
  • Adjust trigger level and mode. Press 자동차 button for automatic setup.
  • Verify input signal with a multimeter if possible.
불안정한 파형
  • Trigger level incorrect
  • Trigger mode unsuitable for signal
  • Noise in the signal
  • Adjust trigger level to be within the waveform's amp위도.
  • Change trigger mode (e.g., Edge, Video, Pulse).
  • Ensure proper grounding and shielding of the signal.
전원이 없습니다
  • 전원 코드가 분리됨
  • 전원 콘센트 결함
  • 내부 퓨즈 끊어짐
  • 전원 코드 연결을 확인하세요.
  • 다른 장치로 전원 콘센트를 테스트하십시오.
  • Contact customer support for fuse replacement.

If the problem persists after attempting these solutions, please contact OWON customer support.

9. 사양

매개변수세부 사항
모델SDS1102
대역폭100MHz
채널2
Samp르 레이트1 GS/s (실시간)
표시하다7-inch Color LCD, 800 x 480 pixels
레코드 길이10K points
인터페이스USB Host, USB Device (supports SCPI, LabVIEW)
자동 측정30가지 유형
전원 공급 장치100V-240V AC, 50/60Hz
치수(길이 x 높이 x 너비)301 x 152 x 70mm(11.85 x 5.98 x 2.75인치)
무게1.1kg(2.43파운드)

10. 보증 및 지원

OWON 제품은 높은 품질 기준에 따라 설계 및 제조되었습니다. 보증 정보는 제품에 동봉된 보증 카드를 참조하시거나 OWON 공식 웹사이트를 방문하십시오. web대지.

For technical support, service, or inquiries, please contact OWON customer service through their official website or the contact information provided in your product documentation. When contacting support, please have your product model (SDS1102) and serial number ready.

제조업체: 오원

관련 문서 - SDS1102

사전view Owon SDS1102+ 함수 발생기가 내장된 디지털 오실로스코프
Owon SDS1102+ 디지털 오실로스코프의 대역폭, s를 포함한 상세 사양 및 기능amp속도, 기록 길이, 자동 측정 및 파형 발생기 기능에 대한 정보가 포함되어 있습니다. 또한 포함된 액세서리 목록도 제공됩니다.
사전view OWON SDS1022 / SDS1102 디지털 저장 오실로스코프 사용자 설명서 - 종합 가이드
이 사용 설명서는 OWON SDS1022 및 SDS1102 디지털 저장 오실로스코프에 대한 자세한 지침과 사양을 제공하며, 설정, 작동, 고급 기능, 문제 해결 및 기술 세부 사항을 다룹니다.
사전view OWON SDS1000 시리즈 디지털 저장 오실로스코프 사양
OWON SDS1000 시리즈 디지털 저장 오실로스코프(SDS1022, SDS1052, SDS1102, SDS1202 모델 포함)의 상세 기술 사양입니다. 대역폭, s 등의 기능을 제공합니다.amp요금, 채널, 디스플레이 등.
사전view OWON TAO3000 시리즈 휴대용 오실로스코프 사용자 설명서
OWON TAO3000 4채널 시리즈 휴대용 오실로스코프 사용 설명서로, 작동 방법, 특징, 기술 사양 및 문제 해결 방법을 자세히 설명합니다.
사전view OWON HDS200 시리즈 2채널 휴대용 오실로스코프 빠른 시작 가이드
이 빠른 시작 가이드는 OWON HDS200 시리즈 2채널 휴대용 오실로스코프(HDS272, HDS242, HDS2102, HDS2202 모델 포함)의 작동에 필요한 필수 정보를 제공합니다. 안전 수칙, 일반 점검, 오실로스코프 및 멀티미터 사용법, 신호 발생기 기능, 소프트웨어 연결, 문제 해결 및 유지 보수에 대한 내용을 다룹니다.
사전view OWON HDS200 시리즈 SCPI 명령 프로토콜 참조
이 문서에서는 OWON HDS200 시리즈 오실로스코프의 SCPI(Standard Commands for Programmable Instruments) 프로토콜에 대해 자세히 설명하며, 수평 설정, 데이터 수집, 채널 구성, 트리거링, 측정 및 함수 발생기 제어에 대한 내용을 다룹니다.