SIMPLEX 4010 9401

SIMPLEX 4010-9401 Addressable Fire Control Unit

사용자 설명서

1. 서론

This manual provides essential information for the proper installation, operation, and maintenance of the SIMPLEX 4010-9401 Addressable Fire Control Unit. This unit is designed to provide reliable fire detection and alarm capabilities for various applications. Please read this manual thoroughly before attempting any procedures to ensure safe and effective use of the system.

2. 안전 정보

중요 안전 지침:

3. 제품 오버view

The SIMPLEX 4010-9401 is a robust addressable fire control unit designed for comprehensive fire detection and alarm management. It features a user-friendly interface with a display and control buttons for system monitoring and interaction.

SIMPLEX 4010-9401 Addressable Fire Control Unit, front view

그림 3.1: 전면 view of the SIMPLEX 4010-9401 Addressable Fire Control Unit. The unit is housed in a red enclosure, featuring a central control panel with a digital display, status indicators, and various control buttons for system management.

주요 구성 요소는 다음과 같습니다.

4. 설정 및 설치

Installation of the SIMPLEX 4010-9401 Fire Control Unit requires specialized knowledge and adherence to strict safety protocols. It is highly recommended that installation be performed by a certified fire alarm technician.

  1. 현장 준비: Ensure the installation location is clean, dry, and within the specified environmental conditions. The unit should be mounted securely to a stable surface.
  2. 전원 연결: Connect the unit to a dedicated 120V AC power supply as per local electrical codes. Ensure proper grounding.
  3. 배선: Connect all addressable devices (smoke detectors, heat detectors, manual pull stations, etc.) and notification appliances (horns, strobes) to the appropriate terminals on the control unit. Follow the wiring diagrams provided in the detailed installation manual (not included here) for correct polarity and termination.
  4. 시스템 구성 : Once all devices are wired, power on the unit. The system will typically perform an initial self-check. Configure the system parameters, device addresses, and zone assignments using the control panel interface or specialized software, as required.
  5. 초기 테스트: Conduct thorough testing of all connected devices and system functions to ensure proper operation before commissioning.

5. 사용 설명서

The 4010-9401 unit is designed for continuous monitoring of your fire alarm system. Here are general operating procedures:

6. 유지관리

Regular maintenance is essential to ensure the continued reliability and performance of your SIMPLEX 4010-9401 Fire Control Unit. It is recommended that maintenance be performed by qualified service personnel.

7. 문제 해결

This section provides general guidance for common issues. For complex problems or persistent faults, contact a qualified fire alarm technician.

문제가능한 원인해결책
전원이 켜지지 않습니다No AC power, blown fuse, internal fault.Check power supply and circuit breaker. Verify fuses. If problem persists, contact service.
Trouble light illuminatedWiring fault, device malfunction, low battery.Check display for specific trouble message. Inspect wiring. Test/replace faulty devices. Check battery condition.
System will not reset after alarmAlarm condition still present, device stuck in alarm.Ensure all alarm conditions are cleared. Inspect detectors and pull stations for activation.
허위 경보Dust in detectors, environmental factors, improper sensitivity.Clean detectors. Review environmental conditions. Have sensitivity checked by technician.

8. 사양

Technical specifications for the SIMPLEX 4010-9401 Addressable Fire Control Unit:

특징세부 사항
모델 번호4010 9401
상표심플렉스
권tage120 볼트
품목 무게50파운드
패키지 크기33 x 27 x 17 인치
제조업체심플렉스
한국어:767571882960

9. 보증 및 지원

For detailed warranty information regarding your SIMPLEX 4010-9401 Addressable Fire Control Unit, please refer to the documentation provided at the time of purchase or contact SIMPLEX directly. Warranty terms may vary based on region and distributor.

For technical support, service, or to schedule professional maintenance, please contact your authorized SIMPLEX distributor or a certified fire alarm system technician. Do not attempt to repair the unit yourself, as this may void the warranty and pose safety risks.

관련 문서 - 4010 9401

사전view Simplex 4010ES: 소멸 자동 명령 시스템
가이드 기술 Simplex 4010ES 세부 사항 모듈 de commande pour les systèmes d'extinction automatique par gicleurs, couvrant les mode déluge et préventif, avec 사양, 승인 및 스키마 드 케이블.
사전view Simplex 4099-9801C IDNet™ 2-Stage Station IAM Installation Instructions
Installation instructions for the Simplex 4099-9801C IDNet™ 2-Stage Station Individual Addressable Module (IAM). Covers mechanical installation, electrical connections, and address configuration for fire alarm systems.
사전view Simplex 4010 화재 경보기: 설치, 작동 및 프로그래밍 가이드
Simplex 4010 화재 경보 시스템 종합 안내서로, 설치, 작동 및 프로그래밍 지침을 포함합니다. 시스템 설명서 포함view, 배선, 구성, 진단 및 문제 해결.
사전view Simplex 4010 화재 경보기: 설치, 작동 및 프로그래밍 가이드
Simplex 4010 화재 경보 시스템 설치, 작동 및 프로그래밍에 대한 종합 안내서입니다.view, 배선, 구성, 진단 및 문제 해결.
사전view Simplex 4010 화재 경보기: 설치, 작동 및 프로그래밍 가이드
Comprehensive guide for installing, operating, and programming the Simplex 4010 Fire Alarm system. Covers system components, wiring, configuration, diagnostics, and troubleshooting.
사전view 심플렉스 4007ES 화재 감지 및 제어 장치 데이터시트
심플렉스 4007ES 화재 감지 및 제어 장치의 상세 데이터시트입니다. MX 디지털 주소 지정 방식 화재 발생 및 알림 기능, 특징, 사양 및 설치 정보를 다룹니다.