QIACHIP KR2202

QIACHIP KR2202 2채널 433MHz 무선 RF 원격 제어 릴레이 스위치 사용 설명서

Brand: QIACHIP | Model: KR2202

1. 서론

This manual provides detailed instructions for the installation, operation, and maintenance of the QIACHIP KR2202 2-Channel 433MHz Wireless RF Remote Control Relay Switch. This universal switch is designed for controlling various electrical devices such as garage door openers, LED lights, and motors, offering flexible functionality with adjustable working modes.

2. 안전 정보

3. 패키지 내용

QIACHIP KR2202 receiver module, protective case, and four remote controls

Image: QIACHIP KR2202 receiver module, protective case, and four remote controls.

4. 제품 사양

사양
상표키아칩
모델KR2202
입력 Voltage교류 85~220V
빈도433MHz
채널2채널
Max Remote Controllers20
전송 거리Up to 164ft/50m (no obstacle)
릴레이 등급10A (each relay)
장착 유형DIN 레일 마운트

5. 설정 및 배선

The KR2202 receiver module supports various wiring configurations for different applications. Always ensure power is disconnected before making any wiring changes.

5.1 General Connection Modes

Diagrams illustrating various circuit connection modes for the QIACHIP KR2202, including AC power, DC power, and different load types.

Image: Diagrams illustrating various circuit connection modes for the QIACHIP KR2202, including AC power, DC power, and different load types.

This diagram shows common wiring setups for AC and DC loads. Pay close attention to the Live (L) and Neutral (N) connections for AC power, and Positive (+) and Negative (-) for DC power. The relay outputs provide Normally Open (NO), Common (COM), and Normally Closed (NC) contacts for flexible control.

5.2 Wiring Diagram for Motors

Wiring diagram for connecting the KR2202 to a DC motor for forward and reverse rotation using AC 85-220V input.

Image: Wiring diagram for connecting the KR2202 to a DC motor for forward and reverse rotation using AC 85-220V input.

For controlling a DC motor with forward and reverse rotation, connect the AC 85-220V input to the 'IN' terminals. The DC motor's two wires are connected to terminals 5 and 2. The positive pole of the external DC power supply connects to terminals 6 and 3, and the negative pole connects to terminals 1 and 4. The live wire of the 220V AC power supply connects to the L interface, and the neutral wire to the N interface, powering the controller.

5.3 Wiring Diagram for Lights

Wiring diagram for connecting the KR2202 to DC lamps using AC 85-220V input.

Image: Wiring diagram for connecting the KR2202 to DC lamps using AC 85-220V input.

To control two DC lamps, connect the positive poles of the lamps to terminals 6 and 3 respectively. The negative poles of the lamps connect to the negative pole of the external DC power supply. The positive pole of the external DC power supply connects to interfaces 5 and 2 respectively. The live wire of the AC power supply connects to the L interface, and the neutral wire connects to the N interface.

6. Remote Control Pairing and Operation

The KR2202 receiver supports Momentary, Toggle, and Latched modes. Follow these steps to pair your remote controls and set the desired operating mode.

6.1 Clearing Existing Codes

  1. Press the 'Learning Button' on the receiver module 8 times.
  2. The indicator light will flash and then go out, indicating that all previously paired remote controls have been cleared.

6.2 Momentary Mode Pairing

In Momentary mode, the relay activates only while the remote button is pressed and deactivates upon release.

  1. Press the 'Learning Button' on the receiver module 1 time. The indicator light will turn on.
  2. Press the first button (e.g., 'A') on your remote control. The indicator light will flash and then go out.
  3. Press the second button (e.g., 'B') on your remote control. The indicator light will flash and then go out.
  4. Pairing is successful. Now, pressing 'A' will activate one relay, and pressing 'B' will activate the other, as long as the button is held down.

6.3 Toggle Mode Pairing

In Toggle mode, pressing a button once activates the relay, and pressing the same button again deactivates it.

  1. Press the 'Learning Button' on the receiver module 2 times. The indicator light will turn on.
  2. Press the first button (e.g., 'A') on your remote control. The indicator light will flash and then go out.
  3. Press the second button (e.g., 'B') on your remote control. The indicator light will flash and then go out.
  4. Pairing is successful. Press 'A' to turn on/off the first relay, and 'B' to turn on/off the second relay.

6.4 Latched Mode Pairing

In Latched mode, pressing one button activates a relay, and pressing another button deactivates it. This mode typically requires a remote with at least two distinct buttons for each channel (e.g., 'A' for ON, 'B' for OFF).

  1. Press the 'Learning Button' on the receiver module 3 times. The indicator light will turn on.
  2. Press the first button (e.g., 'A') on your remote control. The indicator light will flash and then go out.
  3. Press the second button (e.g., 'B') on your remote control. The indicator light will flash and then go out.
  4. Pairing is successful. Press 'A' to activate the first relay, and 'B' to deactivate it.

Important Note for Latched Mode:

Diagrams illustrating the steps for pairing remote controls in Momentary, Toggle, and Latched modes with the QIACHIP KR2202 receiver.

Image: Diagrams illustrating the steps for pairing remote controls in Momentary, Toggle, and Latched modes with the QIACHIP KR2202 receiver.

7. 응용 프로그램

The QIACHIP KR2202 is versatile and can be used in a wide range of applications, from simple domestic remote control to autonomous control systems.

Illustrations of various applications for the QIACHIP KR2202, including motor control, shutter doors, home appliances, electric gates, workshop management, and DC lighting.

Image: Illustrations of various applications for the QIACHIP KR2202, including motor control, shutter doors, home appliances, electric gates, workshop management, and DC lighting.

8. 유지관리

9. 문제 해결

10. 보증 및 지원

QIACHIP products are designed for reliability and performance. For any issues or technical support, please contact QIACHIP customer service. Keep your purchase receipt for warranty claims. The manufacturer is QIACHIP.

관련 문서 - KR2202

사전view QIACHIP KR1201A/KR1201B 12V 1채널 수신기: 설치 및 작동 설명서
QIACHIP KR1201A 및 KR1201B 12V 1채널 RF 릴레이 수신 모듈에 대한 종합 가이드입니다. 배선도, 작동 모드(순간 작동, 토글, 래칭, 지연) 및 조명, 도어록, 모터 제어와 같은 다양한 응용 분야를 위한 설정 절차에 대해 알아보세요.
사전view QIACHIP 12V DC 모터 정방향/역방향 컨트롤러 작동 설명서
이 설명서는 QIACHIP 12V DC 모터 정방향/역방향 컨트롤러 작동 지침을 제공하며, 배선도, 기능 설명, 순간, 토글, 래칭 모드 설정 방법, 그리고 기술 사양을 포함합니다. 또한, 리모컨 페어링 및 장치 재설정 방법도 자세히 설명합니다.
사전view QA-R-011 무선 RF 릴레이 모듈 - QIACHIP 작동 설명서 및 사양
QIACHIP QA-R-011 무선 RF 릴레이 모듈에 대한 종합 가이드입니다. 배선도, 다양한 작동 모드(순간, 토글, 래칭, 시간 지연)에 대한 설정 지침, 그리고 자세한 제품 사양을 제공합니다.
사전view QIACHIP KR1201B 1채널 무선 수신기 모듈: 지침 및 설정
QIACHIP KR1201B 1채널 무선 원격 제어 수신기 모듈에 대한 자세한 지침과 설치 가이드(배선도 및 작업 모드 구성 포함)입니다.
사전view QIACHIP KR1204B 12V 4채널 무선 리모컨 수신기 사용 설명서
QIACHIP KR1204B 12V 4채널 무선 리모컨 수신기에 대한 종합적인 사용 설명서입니다. 배선도, 작동 모드(순간, 토글, 래칭), 설치 지침 및 기술 사양이 포함되어 있습니다.
사전view QIACHIP 433.92Mhz 원격 제어 복제 가이드
QIACHIP 433.92Mhz 4-in-1 복제기를 사용하여 리모컨을 복제하는 방법을 알아보세요. 이 가이드에서는 차고 문과 전동 게이트의 페어링, 코드 삭제, 복구 모드에 대해 설명합니다.