1. 서론
본 매뉴얼은 안전하고 효과적인 사용을 위한 필수 정보를 제공합니다. Mahr AMR-12 Magnification Kit, model 2086960. This kit is specifically designed for the calibration of pneumatic display units, ensuring accurate measurements in industrial and scientific applications. Please read this manual thoroughly before operating the device and retain it for future reference.
Figure 1: Mahr AMR-12 Magnification Kit, model 2086960, showing its primary components.
2. 안전 정보
To ensure safe operation and prevent damage to the device or injury to personnel, observe the following safety precautions:
- Always handle the magnification kit with care. It is a precision instrument.
- Do not expose the kit to extreme temperatures, humidity, or corrosive environments.
- Avoid dropping or subjecting the kit to strong impacts.
- Only use the kit for its intended purpose: the calibration of pneumatic display units.
- Keep the kit clean and free from dust and debris.
- Do not attempt to disassemble or modify the kit. Refer servicing to qualified personnel.
3. 패키지 내용
The Mahr AMR-12 Magnification Kit, model 2086960, includes the following components:
- Magnification Kit components (as specified by Mahr)
Upon unpacking, inspect all items for any signs of damage. If any components are missing or damaged, contact your supplier immediately.
4. 설정
Follow these steps to set up your Mahr AMR-12 Magnification Kit:
- 풀다: 포장에서 모든 구성 요소를 조심스럽게 제거합니다.
- 검사: Visually inspect all parts for any damage that may have occurred during shipping.
- 환경: Ensure the working environment is clean, stable, and free from vibrations. Maintain a consistent temperature and humidity as recommended for precision instruments.
- 집회: Assemble the magnification kit components according to the specific instructions provided with the kit's internal documentation (if applicable). Ensure all connections are secure.
- 준비: Prepare the pneumatic display unit that requires calibration according to its own instruction manual.
5. 사용 설명서
The Mahr AMR-12 Magnification Kit is designed for precise calibration. Follow these general operating procedures:
- 연결: Connect the magnification kit to the pneumatic display unit as per the calibration procedure. Ensure a secure and leak-free connection.
- 교정 절차: Follow the specific calibration steps outlined in the documentation for the pneumatic display unit and the magnification kit. This typically involves applying known pressure values and observing the display unit's readings through the magnification kit.
- 관찰: Use the magnification kit to accurately read the fine scales or indicators on the pneumatic display unit. The kit enhances visibility for precise measurement.
- 기록 데이터: Record all calibration data meticulously.
- 단절: After calibration, carefully disconnect the magnification kit from the pneumatic display unit.
Note: Specific calibration procedures may vary depending on the pneumatic display unit being calibrated. Always refer to the primary instrument's manual for detailed steps.
6. 유지관리
Proper maintenance ensures the longevity and accuracy of your Mahr AMR-12 Magnification Kit:
- 청소: Use a soft, lint-free cloth to clean the surfaces of the kit. For optical components, use specialized lens cleaning solutions and cloths to avoid scratching.
- 저장: Store the kit in its original packaging or a protective case when not in use. Keep it in a dry, dust-free environment with stable temperature.
- 점검: Periodically inspect the kit for any signs of wear, damage, or loose components.
- 구경 측정: While the kit itself is a calibration aid, ensure it is handled with care to maintain its optical and mechanical integrity.
7. 문제 해결
This section addresses common issues you might encounter with the Mahr AMR-12 Magnification Kit:
| 문제 | 가능한 원인 | 해결책 |
|---|---|---|
| Unclear image/view through magnification kit | Dust or smudges on optical components; improper focus. | Clean optical surfaces with appropriate cleaning materials. Adjust the focus mechanism if available. |
| Kit components feel loose | Connections not fully tightened. | Gently tighten any adjustable connections. Do not overtighten. |
| Inaccurate calibration results | Improper setup; environmental factors; faulty pneumatic unit. | Review setup steps. Ensure stable environment. Verify the pneumatic display unit's condition. The magnification kit itself does not introduce inaccuracy if properly used. |
If you encounter issues not listed here or if the suggested solutions do not resolve the problem, contact Mahr customer support.
8. 사양
| 특징 | 세부 사항 |
|---|---|
| 상표 | 마흐르 |
| 모델 번호 | 2086960 |
| 제조업체 | 마흐르 GmbH |
| 제품 크기(L x W x H) | 50 x 21.6 x 19.7cm |
| 품목 무게 | 1킬로그램 |
| 패키지의 항목 | 1 |
| 측정 정밀도 | +/-0.5% |
| 포함된 구성 요소 | Magnification Kit |
| 필요한 배터리 | 아니요 |
| ASIN | B07Z9CSWDK |
9. 보증 및 지원
For information regarding warranty coverage, technical support, or spare parts availability for your Mahr AMR-12 Magnification Kit, please contact Mahr GmbH directly or your authorized Mahr distributor. Keep your purchase receipt and model number (2086960) handy when contacting support.
참고: 예비 부품 가용성에 대한 정보는 현재 제공되지 않습니다.