1. 서론

This manual provides essential information for the installation, operation, and maintenance of the BANNER ENGINEERING S18AW3FF50 EZ-Beam S18 Series Photoelectric Sensor. This sensor is designed for reliable object detection in industrial environments, featuring a 50 mm range, 20-250VAC input, and SPST solid-state light operate output.

BANNER ENGINEERING S18AW3FF50 Photoelectric Sensor

Figure 1: BANNER ENGINEERING S18AW3FF50 Photoelectric Sensor with coiled cable.

2. 설정 및 설치

최적의 성능과 안전을 위해서는 올바른 설치가 매우 중요합니다. 다음 단계를 주의 깊게 따르세요.

2.1 풀기 및 검사

2.2 센서 장착

The S18AW3FF50 sensor is designed for easy mounting. Ensure the mounting surface is stable and free from excessive vibration.

  1. Select a mounting location that provides clear line-of-sight for the sensor's detection range (50 mm).
  2. Secure the sensor using appropriate mounting hardware (not included). The sensor features a threaded barrel for secure attachment.
  3. Ensure the sensor is oriented correctly for the intended detection application.
S18AW3FF50 Sensor with cable coiled

그림 2: 측면 view of the S18AW3FF50 sensor, showing the threaded barrel and cable.

2.3 전기 연결

경고: Disconnect all power before making electrical connections to prevent electric shock or damage to the equipment.

The S18AW3FF50 operates on 20-250VAC input and provides an SPST Solid-State Light Operate output. The sensor comes with a 2M (6.5FT) cable.

Table 1: Wiring Diagram for S18AW3FF50
와이어 색상기능
갈색AC Line (L1)
파란색AC Neutral (L2)
검은색Output (SPST Light Operate)

Connect the sensor wires to the control circuit according to the provided wiring diagram and local electrical codes. Ensure all connections are secure.

S18AW3FF50 Sensor with exposed wires

Figure 3: S18AW3FF50 sensor showing the cable with exposed wires for electrical connection.

3. 운영

Once installed and wired, the S18AW3FF50 sensor is ready for operation.

3.1 전원 켜기

Apply power to the sensor (20-250VAC). The sensor will typically have an indicator LED (if present) to show power status and output state.

3.2 Detection Principle

The S18AW3FF50 is a photoelectric sensor operating in a fixed field mode. It emits a light beam and detects objects based on the reflection or interruption of this beam. The "Light Operate" output means the output will be active when light is received by the sensor (i.e., when an object is detected or not detected, depending on the specific fixed field configuration).

3.3 범위 및 성능

The sensor has a specified detection range of 50 mm. Ensure that objects to be detected fall within this range for reliable operation. Environmental factors such as dust, moisture, and ambient light can affect performance.

4. 유지관리

The S18AW3FF50 sensor is designed for low maintenance. Regular checks can ensure long-term reliable operation.

4.1 청소

4.2 케이블 및 연결 검사

5. 문제 해결

This section provides solutions to common issues encountered with the S18AW3FF50 sensor.

표 2: 문제 해결 가이드
문제가능한 원인해결책
센서 전원이 켜지지 않음No power supply; Incorrect wiring; Damaged sensor.Verify power supply (20-250VAC); Check wiring against Table 1; Replace sensor if damaged.
센서가 물체를 감지하지 못합니다Object out of range (50 mm); Dirty lens; Misalignment; Ambient light interference.Ensure object is within 50 mm range; Clean sensor lens; Realign sensor; Shield sensor from strong ambient light.
간헐적 감지Vibration; Loose connections; Fluctuating power.Secure sensor mounting; Check all electrical connections; Ensure stable power supply.

6. 사양

Key technical specifications for the BANNER ENGINEERING S18AW3FF50 Photoelectric Sensor.

7. 보증 및 지원

For warranty information and technical support, please contact BANNER ENGINEERING directly or refer to their official web대지.

반품 정책: The product may be subject to a return policy of 30 days for refund/replacement, as per the seller's terms.

제조업체: BANNER ENGINEERING

추가 지원을 받으려면 다음을 방문하세요. BANNER ENGINEERING official web대지.

관련 문서 - S18AW3FF50

사전view Banner S18 Series AC Voltage Sensors: Installation Guide and Specifications
Comprehensive guide to Banner Engineering's S18 Series AC Voltage sensors, covering installation, models, wiring, dimensions, specifications, and accessories. Features detailed technical data for various sensing modes including opposed, retro-reflective, polarized retro-reflective, and diffuse.
사전view Understanding Light Operate and Dark Operate Sensor Modes | Banner Engineering
Banner Engineering's iKnow Training Note explains the operational principles of Light Operate (LO) and Dark Operate (DO) modes for photoelectric sensors, detailing Opposed, Retroreflective, and Proximity sensing configurations.
사전view QS18AF40 Background Suppression Sensor | Banner Engineering
Datasheet and installation guide for the Banner QS18AF40 WORLD-BEAM® mechanically adjustable background suppression sensor (15-40mm range). Features, specifications, wiring, and performance curves.
사전view Banner Sonic OMNI-BEAM™ Ultrasonic Proximity Sensors Datasheet
Comprehensive datasheet for Banner Engineering's Sonic OMNI-BEAM™ piezoelectric ultrasonic proximity sensors. Details features, specifications, operating modes, power block selection, adjustment procedures for relay and analog outputs, application notes, and the basic theory of ultrasonic sensing.
사전view Banner WORLD-BEAM QS30 Series DC Voltage Photoelectric Sensor Instruction Manual
Comprehensive instruction manual for the Banner WORLD-BEAM QS30 Series DC Voltage photoelectric sensor, detailing features, models, specifications, fixed-field operation, wiring, and performance.
사전view Banner WORLD-BEAM QS18 Expert with IO-Link Quick Start Guide
Quick start guide for the Banner WORLD-BEAM QS18 Expert photoelectric sensor with IO-Link. It provides essential information on setup, installation, wiring, configuration, specifications, and safety warnings for industrial automation applications.