엘리텍 RC-51

Elitech RC-51 디지털 온도 데이터 로거 사용 설명서

모델 : RC-51

소개

The Elitech RC-51 is a reusable digital temperature data logger designed for precise and reliable temperature monitoring. It features a USB interface for direct connection to a computer, allowing for automatic PDF report generation without the need for specialized software. This device is capable of recording up to 32,000 temperature points across a wide range, making it suitable for various applications requiring accurate temperature data.

This manual provides comprehensive instructions for setting up, operating, and maintaining your RC-51 data logger.

제품 끝view

Elitech RC-51 Digital Temperature Data Logger

Figure 1: Elitech RC-51 Digital Temperature Data Logger

This image displays the Elitech RC-51 digital temperature data logger, showcasing its pen-style design with a transparent cap covering the USB connector and an integrated LCD screen.

주요 특징:

구성 요소:

Elitech RC-51 Data Logger Components Diagram

Figure 2: Labeled Components of the RC-51 Data Logger

This diagram labels the key components of the RC-51 data logger: 1. Transparent cap, 2. USB port, 3. LCD screen, 4. Seal ring, 5. Button & Bi-color indicator (red and green), 6. Temperature Sensor.

Video 1: Elitech RC-51 Series Temperature/Humidity Data Logger Overview

이 영상은 일반적인 내용을 제공합니다.view of the Elitech RC-51 series data loggers, highlighting their design and primary functions.

설정

1. 배터리 설치

The RC-51 uses one Lithium Metal battery (included). Ensure the battery is correctly installed before initial use.

  1. Carefully remove the back panel of the data logger.
  2. Insert the Lithium Metal battery, ensuring correct polarity.
  3. Replace the back panel securely.

2. Initial Configuration (Optional, via Software)

While the RC-51 can generate PDF reports without software, advanced settings like log interval, start mode, and alarm thresholds can be configured using the Elitechlog software. This software is available for both Windows and Mac platforms.

Video 2: Elitech Software for RC-5+ & RC-5+-TE (Relevant for RC-51 software setup)

This video demonstrates how to download and use the Elitechlog software for configuring data loggers, including setting parameters like log interval, start mode, and alarm thresholds. Although it references RC-5+, the process is similar for the RC-51.

  1. Elitechlog 소프트웨어는 Elitech 공식 웹사이트에서 다운로드하세요. web대지.
  2. Install the software on your computer (Windows or Mac).
  3. Remove the transparent cap from the RC-51 and plug the data logger into a USB port on your computer.
  4. Open the Elitechlog software. The device information should appear.
  5. Navigate to the 'Settings' or 'Parameter' tab within the software.
  6. Configure desired settings:
    • 로그 간격: Set how frequently the device records data (e.g., every 10 seconds to every 12 hours).
    • 시작 모드 : Choose between 'Start by button-press', 'Start immediately', or 'Timer start' (pre-set time).
    • 온도 단위 : Select Fahrenheit (℉) or Celsius (°C).
    • 시간대: Adjust the time zone as needed.
    • 알람 설정: Define up to 5 high and low temperature alarm thresholds.
  7. Click 'Save' to apply the settings to the data logger.
  8. Safely eject the data logger from your computer.

Operating the Data Logger

1. 데이터 로깅 시작

Depending on your configured start mode:

2. ViewLCD에 데이터 표시

Press the left button (Play/Start) briefly to cycle through the following information on the LCD display:

Video 3: Elitech RC-51/RC-51H Data Logger Operation Guide

This video provides a detailed guide on operating the Elitech RC-51/RC-51H data logger, including starting and stopping logging, and navigating the LCD display.

3. 데이터 로깅 중지

Depending on your configured stop mode:

4. Generating Reports

The RC-51 automatically generates a PDF report when plugged into a computer.

  1. Remove the transparent cap and plug the data logger into a USB port on your computer.
  2. The device will appear as a removable drive. A PDF file containing the data log will be automatically generated and saved to the device.
  3. PDF를 엽니다 file 에게 view the temperature data, including a graph, statistics, and a table of all recorded points.
  4. For Excel reports or further analysis, open the Elitechlog software, connect the device, and use the 'Export Data' function to save data in Excel format.
Elitech RC-51 Generating PDF Report

Figure 3: Automatic PDF Report Generation

This image illustrates the Elitech RC-51 data logger connected to a laptop, demonstrating its ability to automatically generate a PDF report without requiring additional software installation.

유지

1. 청소

Wipe the device clean with a soft, dry cloth. Do not use abrasive cleaners or solvents.

2. 배터리 교체

The RC-51 uses a replaceable Lithium Metal battery. If the battery indicator on the LCD is low or the device does not power on, replace the battery by following the installation steps in the 'Setup' section.

3. 보관

Store the data logger in a cool, dry place away from direct sunlight and extreme temperatures when not in use.

문제 해결

문제가능한 원인해결책
장치의 전원이 켜지지 않습니다.배터리가 부족하거나 방전되었습니다.Replace the Lithium Metal battery.
No PDF report generated.Device not properly connected to USB port; USB port malfunction.Ensure secure USB connection. Try a different USB port or computer.
Logging does not start.Incorrect start mode configuration; button not pressed long enough.Verify start mode in Elitechlog software. Ensure button is held for 5 seconds.
온도 판독값이 부정확합니다.Device exposed to extreme conditions; calibration needed.Ensure device is used within specified operating range. Contact support for calibration information.

명세서

특징세부 사항
모델RC-51
온도 측정 범위-30°C to +70°C (-22℉ to 158℉)
온도 정확도±0.5°C(±0.9°C)
해결0.1°C / 0.1℉
데이터 저장 용량32,000점
로그 간격10초에서 12시간까지 설정 가능
시작 모드Button press, pre-set time, or start delay
정지 모드Button press, software stop, or full memory
알람 설정Up to 5 configurable alarm thresholds
표시하다액정표시장치
인터페이스USB 2.0
전원 공급 장치1 x CR2032 Lithium Metal battery (included)
보호 등급IP67 (방수)
인증CE, FDA
재료폴리카보네이트(PC)
치수Approx. 3.14" x 0.99" (as per image)
Elitech RC-51 Data Logger Dimensions

Figure 4: Elitech RC-51 Data Logger Dimensions

This image provides a visual representation of the RC-51 data logger's dimensions, indicating a length of approximately 3.14 inches and a width of 0.99 inches.

보증 및 지원

보증 정보

The Elitech RC-51 data logger typically comes with a manufacturer's warranty. Please refer to the included warranty card or the official Elitech website for specific terms and conditions regarding your product's warranty period and coverage.

Elitech RC-51 Two-year Validation Certificate

그림 5: 예ample of a Two-year Validation Certificate

This image displays an example of a two-year validation certificate for an Elitech data logger, indicating calibration and expiration dates. A similar certificate may be included with your RC-51.

기술 지원

For technical assistance, troubleshooting, or inquiries regarding calibration certificates, please contact Elitech customer support. 24/7 US Technician Support is available via email and phone.

관련 문서 - RC-51

사전view Elitech RC-51 데이터 로거 사용자 매뉴얼
Elitech RC-51 온도 데이터 로거의 사용 설명서로, 기능, 사양, 설치, 작동, 데이터 기록 및 배터리 교체 절차에 대한 자세한 내용을 담고 있습니다.
사전view Elitech RC-51 다용도 온도 데이터 로거 사용 설명서
Elitech RC-51 다용도 온도 데이터 로거의 제품 전반에 걸친 포괄적인 사용자 설명서입니다.view기술 사양, 작동 지침, 디스플레이 메뉴, 보고서 생성 및 배터리 교체에 대한 내용이 포함되어 있습니다.
사전view Elitech RC-51 다용도 온도 데이터 로거 - 기술 사양
정확성과 신뢰성을 위해 설계된 다용도 온도 데이터 로거인 Elitech RC-51을 살펴보십시오. 이 문서에서는 RC-51 모델의 기술 사양, 기능 및 소프트웨어 다운로드 정보를 제공합니다.
사전view Elitech RC-51 다목적 온도 데이터 로거 사용 설명서 및 사양
Elitech RC-51 다목적 온도 데이터 로거에 대한 포괄적인 가이드, 제품 범위 포함view, 기술 매개변수, 사용 지침, 데이터 viewing, 배터리 교체 및 PDF 보고서 콘텐츠가 포함되어 있습니다. 넓은 온도 범위, 높은 정확도, 물류 및 콜드 체인 모니터링을 위한 대용량 저장 용량 등의 특징이 있습니다.
사전view Elitech RC-5+ 온도 데이터 로거: 사용 설명서 및 사양
이 설명서는 Elitech RC-5+ USB 온도 데이터 로거의 자세한 사용 설명서를 제공하며, 설정, 작동, 데이터 다운로드 및 Elitech 소프트웨어를 이용한 분석 방법을 다룹니다. 또한, 기능 및 기술 사양도 포함되어 있습니다.
사전view Elitech RC-5 빠른 시작 가이드: 온도 데이터 로거
Elitech RC-5 온도 데이터 로거에 대한 빠른 시작 가이드로, 배터리 설치, 소프트웨어 설정, 로거 작동, 기술 사양 및 문제 해결 방법을 다룹니다.