소개
This document serves as the official instruction manual for the Tektronix T912 10 MHz Storage Oscilloscope. It provides comprehensive information regarding the setup, operation, maintenance, and troubleshooting of the instrument. Users are advised to read this manual thoroughly to ensure safe and efficient use of the Tektronix T912 oscilloscope.
안전 정보
Always observe the following safety precautions when operating the Tektronix T912 oscilloscope:
- 전원: 지정된 전압의 전원에만 기기를 연결하십시오.tage and frequency. Ensure proper grounding.
- 통풍: 통풍구를 막지 마십시오. 과열을 방지하려면 적절한 공기 흐름이 필수적입니다.
- 환경 조건: Operate the oscilloscope in a dry environment, away from moisture, dust, and extreme temperatures.
- Probes and Cables: Use only probes and cables designed for the instrument and rated for the voltages being measured.
- 서비스: 모든 서비스는 자격을 갖춘 서비스 담당자에게 의뢰하십시오. 기기를 직접 열거나 수리하려고 시도하지 마십시오.
- 높은 Voltage: 높은 볼륨에 주의tage hazards. Always disconnect power before making or changing connections, especially when dealing with high voltag전자 회로.
제품 끝view: The Instruction Manual
이 섹션에서는 다음을 제공합니다.view of the physical instruction manual itself, which guides users through the operation of the Tektronix T912 10 MHz Storage Oscilloscope.

Figure 1: Front Cover of the Instruction Manual. This image displays the blue front cover of the Tektronix T912 10 MHz Storage Oscilloscope Instruction Manual. The Tektronix logo is prominently featured at the top, with "T912 10 MHz STORAGE OSCILLOSCOPE WITH OPTIONS" and "INSTRUCTION MANUAL" printed below. The manual is spiral-bound on the left side.

Figure 2: Inside Cover Page of the Instruction Manual. This image shows the inside cover page of the manual. It features the Tektronix logo with "COMMITTED TO EXCELLENCE" below it. Text prompts the user to "PLEASE CHECK FOR CHANGE INFORMATION AT THE REAR OF THIS MANUAL." Details about the T912 model, storage oscilloscope, and instruction manual are visible, along with Tektronix Inc. contact information, product group, serial number, and printing dates (First Printing JUL 1975, Revised JUL 1982).

Figure 3: Back Cover of the Instruction Manual. This image displays the plain blue back cover of the spiral-bound instruction manual. It matches the front cover's color and texture, showing the spiral binding along the left edge.
설정
Proper setup is crucial for accurate measurements and safe operation. Follow these general steps:
- 짐 풀기: Carefully remove the oscilloscope and all accessories from its packaging. Inspect for any signs of shipping damage.
- 놓기: Place the oscilloscope on a stable, level surface with adequate ventilation space around it.
- 전원 연결: Connect the power cord to the instrument and then to a grounded AC power outlet matching the specified voltage.
- 프로브 연결: Connect the desired probes to the input channels. Ensure probes are properly compensated before use.
- 초기 전원 켜기: Turn on the oscilloscope and allow it to warm up for a few minutes as per the specific instructions in the full manual.
작동 지침
The Tektronix T912 is a 10 MHz storage oscilloscope designed for capturing and displaying waveforms. Basic operation involves:
- 전원 켜기/끄기: 주 전원 스위치를 사용하여 장치를 켜거나 끕니다.
- 수직 컨트롤: Adjust the VOLTS/DIV knob for each channel to set the vertical sensitivity. Use the POSITION knob to move the waveform vertically.
- 수평 제어: Adjust the SEC/DIV knob to set the time base. Use the POSITION knob to move the waveform horizontally.
- 트리거링: Set the TRIGGER LEVEL and SOURCE to stabilize the waveform display. The T912, being a storage oscilloscope, allows for capturing single-shot events.
- 저장 기능: Utilize the storage controls to capture and hold transient or non-repetitive waveforms on the screen for detailed analysis. Refer to the full manual for specific storage mode operations.
- Focus and Intensity: Adjust these controls for a clear and bright display.
유지
Regular maintenance ensures the longevity and performance of your oscilloscope:
- 청소: 청소하기 전에 전원을 분리하세요. 부드러운 천을 사용하세요.amp cloth with a mild detergent to clean the exterior. Avoid abrasive cleaners or solvents.
- 저장: 사용하지 않을 때는 오실로스코프를 먼지와 극한 온도로부터 보호되는 깨끗하고 건조한 환경에 보관하십시오.
- 구경 측정: Periodically, the oscilloscope may require calibration to maintain accuracy. Refer to the detailed calibration procedures in the complete service manual or contact qualified service personnel.
- 프로브 관리: Inspect probes regularly for damage. Keep probe tips clean.
문제 해결
If you encounter issues with your Tektronix T912, consider the following common troubleshooting steps:
- 디스플레이 없음:
- 전원 연결 상태와 퓨즈를 확인하십시오.
- Ensure intensity and focus controls are not set to minimum.
- Verify that the oscilloscope is powered on.
- 불안정한 파형:
- Adjust the trigger level and source settings.
- Check probe connections and compensation.
- 입력 신호가 오실로스코프의 측정 범위 내에 있는지 확인하십시오.
- 신호가 표시되지 않음:
- Verify the input signal is present at the probe tip.
- Check channel selection and vertical position.
- Ensure the probe is correctly connected to the circuit under test.
- 왜곡된 파형:
- Check probe compensation.
- Ensure the signal amplitude does not exceed the vertical range.
- Verify the signal frequency is within the oscilloscope's bandwidth.
For more detailed troubleshooting, consult the complete instruction manual or contact Tektronix support.
명세서
The following specifications apply to the Tektronix T912 10 MHz Storage Oscilloscope:
| 특징 | 세부 사항 |
|---|---|
| 제조업체 | 텍트로닉스 |
| 모델 | T912 |
| 대역폭 | 10MHz |
| 유형 | 스토리지 오실로스코프 |
| 호환 장치 | Personal computer (as per product listing) |
| 그래픽 카드 인터페이스 | Integrated (as per product listing) |
Note: Some specifications like "Compatible Devices" and "Graphics Card Interface" are derived from the product listing and may refer to specific configurations or accessories. For detailed technical specifications, refer to the original Tektronix T912 service manual.
보증 및 지원
For warranty information, please refer to the documentation provided at the time of purchase or contact the seller (ROA) or the manufacturer (Tektronix) directly. Support resources, including technical assistance and service options, can typically be found on the official Tektronix web해당 사이트를 방문하거나 고객 서비스 부서에 문의하세요.
Tektronix, Inc.
우편번호 500
비버튼, 오레곤 97077
First Printing JUL 1975
Revised JUL 1982