1. 서론
This manual provides essential information for the safe and efficient installation, operation, and maintenance of your ESBE VTA 323 KF 22 Mm Thermostatic Mixing Valve. Please read these instructions carefully before installation and retain them for future reference.
2. 안전 정보
중요 안전 지침:
- 설치는 현지 규정 및 기준에 따라 자격을 갖춘 전문가가 수행해야 합니다.
- 설치 또는 유지 보수 작업을 시작하기 전에 반드시 메인 급수 밸브를 잠그십시오.
- Do not modify the valve or its components. Use only genuine ESBE spare parts.
- 밸브가 얼지 않도록 보호하십시오.
- 설치 및 유지 관리 시에는 항상 적절한 개인 보호 장비(PPE)를 착용하세요.
3. 제품 오버view
The ESBE VTA 323 KF 22 Mm is a thermostatic mixing valve designed for domestic hot water applications. It ensures a constant and safe mixed water temperature at the outlet, protecting against scalding and optimizing energy consumption.

그림 1: ESBE VTA 323 KF 22 Mm Thermostatic Mixing Valve. This image displays the brass body of the valve with a dark grey plastic top housing. The ESBE logo is visible on the front, along with red and blue arrows indicating hot and cold water inlets and a mixed water outlet.
3.1 주요 구성 요소
- 밸브 바디: Brass construction for durability.
- Thermostatic Element: Automatically adjusts the mixing ratio of hot and cold water.
- 입구: Clearly marked for hot (red) and cold (blue) water.
- 콘센트: For mixed water supply.
- Adjustment Knob/Cap: For setting the desired mixed water temperature (under the dark grey cap).
4. 설정 및 설치
Follow these steps for proper installation of the ESBE VTA 323 KF 22 Mm valve:
- 준비: Turn off the main water supply. Drain the system to relieve pressure.
- 위치: Install the valve in an easily accessible location for future maintenance. Ensure the flow direction arrows on the valve body match the system's water flow. The hot water inlet is typically marked with red, and the cold water inlet with blue.
- 사이: Connect the hot water supply to the designated hot inlet, and the cold water supply to the cold inlet. Connect the mixed water outlet to the distribution system. Use appropriate sealing materials (e.g., PTFE tape or hemp) on threaded connections to prevent leaks. The 22 mm connections are designed for standard plumbing.
- 누출 확인: Once all connections are secure, slowly open the main water supply and check for any leaks. Tighten connections as necessary.
- 초기 온도 설정: Refer to the "Operating Instructions" section to set the desired mixed water temperature.
5. 사용 설명서
The ESBE VTA 323 KF 22 Mm valve is largely automatic once the desired temperature is set. The primary operation involves setting and, if necessary, adjusting the mixed water temperature.
- Accessing Adjustment: The temperature adjustment mechanism is typically located under the dark grey protective cap on top of the valve. Carefully remove this cap.
- 설정 온도: Rotate the adjustment knob (or screw) to increase or decrease the mixed water temperature. Turn towards the 'hot' indicator (often red) to increase temperature, and towards the 'cold' indicator (often blue) to decrease it.
- 확인: Use a thermometer to verify the mixed water temperature at a tap downstream from the valve. Adjust as needed until the desired safe temperature (e.g., 38-45°C for domestic use) is achieved.
- Securing Setting: Once the desired temperature is set, replace the protective cap.
6. 유지관리
Regular maintenance ensures the longevity and optimal performance of your ESBE VTA 323 KF 22 Mm valve.
- 연례 검사: Annually inspect the valve for any signs of leaks, corrosion, or damage.
- 온도 확인: Periodically verify the mixed water temperature with a thermometer to ensure it remains at the desired setting. Recalibrate if necessary.
- 청소: In areas with hard water, mineral deposits may accumulate. If the valve's performance degrades (e.g., inconsistent temperature), it may require cleaning. This typically involves disassembling the valve, cleaning the internal components (especially the thermostatic element) with a suitable descaling solution, and reassembling it. This procedure should ideally be performed by a qualified technician.
- 예비 부품: If any components need replacement, use only genuine ESBE spare parts.
7. 문제 해결
| 문제 | 가능한 원인 | 해결책 |
|---|---|---|
| Inconsistent mixed water temperature | Fluctuating inlet pressures; clogged thermostatic element; sediment buildup. | Check system pressures. Clean or descale the thermostatic element. Inspect for sediment. |
| No hot water or only cold water | Hot water supply failure; valve stuck in cold position; severe blockage. | Verify hot water supply. Inspect and clean the valve internals. |
| No cold water or only hot water | Cold water supply failure; valve stuck in hot position; severe blockage. | Verify cold water supply. Inspect and clean the valve internals. |
| Water leakage from valve | Loose connections; damaged seals/gaskets; cracked valve body. | Tighten connections. Replace seals/gaskets. If valve body is cracked, replace the entire valve. |
If you are unable to resolve an issue, contact a qualified plumber or ESBE customer support.
8. 사양
- 제조업체: 에스베
- 모델: VTA 323 KF 22 Mm
- 품목 무게: 1kg
- ASIN: B07L25C8HD
- 첫 번째 가능한 날짜: 15년 2020월 XNUMX일
- 연결 크기 : 22 mm (KF refers to compression fittings)
- Note: Specific temperature range and flow rates are typically detailed in the product's technical data sheet.
9. 보증 및 지원
For warranty information, please refer to the documentation provided with your purchase or visit the official ESBE website. For technical support or inquiries regarding spare parts, please contact your local ESBE distributor or customer service department.
ESBE Contact Information: 방문해주세요 www.esbe.eu 지역 연락처는





