1. 제품 오버view
The FAAC Photobeam Safety Eye XP 30 is a wall-mounted photocell designed for gate opener safety applications. It provides a reliable safety barrier by detecting obstructions in the gate's path, preventing potential accidents.
Key features include a channel selection ability that uses coded signals to prevent interference from other nearby photocells, allowing up to four pairs of XP 30 units to be installed in close proximity without issues. The unit is also protected against interference from external light sources, such as LED headlights, ensuring consistent performance.
This model is suitable for both wall and flush/column-mounted installations with an appropriate adapter.
2. 안전 정보
중요한: Read all instructions carefully before installation and operation. Failure to follow these instructions may result in injury or damage to the product.
- 이 장치는 UL 325 준수 when used with FAAC Control Boards, ensuring adherence to safety standards for gate operators.
- Installation and wiring should be performed by qualified personnel in accordance with local electrical codes and regulations.
- 설치, 유지보수 또는 문제 해결 작업을 수행하기 전에 반드시 전원 공급 장치를 차단하십시오.
- Do not modify the product in any way. Use only original FAAC replacement parts if necessary.
- Keep the area around the photocells clear of obstructions that could block the beam or interfere with detection.
3. 설치
The FAAC XP 30 photocell can be installed in a wall-mounted configuration or flush/column-mounted using an adapter (sold separately).
3.1 Mounting the Photocell
- Choose a suitable mounting location for both the transmitter (TX) and receiver (RX) units, ensuring they are aligned and have a clear line of sight. The maximum distance between units is 100 ft. (30 m).
- Securely mount the photocell units using appropriate fasteners for the chosen surface. The plastic body with a moulded front seal cover and closed-cell cable routing area seal provides protection against environmental elements.
- Ensure the units are level and facing each other directly for optimal performance.

그림 1: 앞쪽 view of the FAAC XP 30 Photobeam Safety Eye. This image displays the compact design of the photocell unit, highlighting its robust plastic body and potential mounting points. The unit is designed for easy integration into gate opener systems.
3.2 배선
- Connect the power supply (24V) to both the transmitter and receiver units as per the wiring diagram provided with your FAAC control board.
- The output type is Relay - N.C./N.O. (Normally Closed/Normally Open). Connect the relay output from the receiver to the safety input of your FAAC gate opener control board.
- Ensure all connections are secure and properly insulated to maintain the IP54 protection class.
3.3 채널 선택
The XP 30 features 4 Channel Relay Selection. This allows for the installation of up to 4 separate photocell pairs in close proximity without interference. Refer to the specific instructions provided with your FAAC control board for details on setting the channel for each pair.
3.4 정렬
The XP 30 features Automatic Auto-Alignment with an angle of 7º - 13.5º. After power-up, the units will automatically attempt to align. Ensure a clear line of sight between the TX and RX units. Indicators on the units (refer to the specific product diagram) will confirm successful alignment.
4. 운영
Once properly installed and aligned, the FAAC XP 30 photocells continuously emit and receive an infrared beam. If an object or person breaks this beam while the gate is in motion, the photocells will signal the gate opener control board to stop or reverse the gate's movement, preventing impact.
The coded signals ensure that only the intended transmitter and receiver communicate, minimizing false triggers from other light sources or nearby photocell installations.
5. 유지관리
Regular maintenance ensures optimal performance and longevity of your FAAC XP 30 photocells.
- 청소: 송신기와 수신기 장치의 렌즈를 부드러운 천으로 주기적으로 청소하십시오.amp cloth to remove dust, dirt, or debris that may obstruct the beam. Do not use abrasive cleaners.
- 점검: Regularly inspect the wiring for any signs of damage, fraying, or loose connections. Ensure the mounting hardware is secure.
- 기능성 테스트: Periodically test the photocells by intentionally breaking the beam with an object (e.g., a cardboard box) while the gate is closing to ensure it stops or reverses as intended.
6. 문제 해결
| 문제 | 가능한 원인 | 해결책 |
|---|---|---|
| Gate does not respond to photocell beam interruption. |
|
|
| False triggers or intermittent operation. |
|
|
| No power indicator on units. |
|
|
If problems persist after attempting these solutions, contact FAAC technical support or a qualified technician.
7. 사양
| 최대 거리 | 100의 피트 (30 m) |
| 전원 공급 장치tage | 24V |
| Absorbed Current (RX) | 30mA |
| Absorbed Current (TX) | 20mA |
| 연락처 등급 | 60VA / 24W |
| 조정 | Automatic Auto-Alignment |
| Auto-Alignment Angle | 7º - 13.5º |
| 출력 유형 | Relay - N.C./N.O. |
| 보호 등급 | IP54 |
| 작동 온도 | -4°F ~ 131°F(-20°C ~ 55°C) |
| 치수(LxHxD) | 2.16" x 3" x 0.82"(55mm x 76mm x 21mm) |
| 규정 준수 | UL 325 Compliant (when used with FAAC Control Boards) |
8. 보증 및 지원
For warranty information, please refer to the documentation provided with your purchase or contact FAAC directly. Technical support is available through FAAC's official channels for assistance with installation, operation, or troubleshooting.
FAAC 공식 웹사이트를 방문하세요. web최신 지원 자료 및 연락처 정보를 확인할 수 있는 사이트입니다.