1. 제품 오버view
The BELL 5874-5S is a 1-gang complete flip cover kit designed for outdoor electrical installations. It includes a self-test GFCI (Ground Fault Circuit Interrupter) receptacle, a weatherproof box, and a flip cover, all in a gray finish. This unit provides enhanced safety by protecting against electrical shocks in wet or damp 위치.
주요 특징:
- Self-test GFCI for continuous safety monitoring.
- Rugged die-cast construction for durability.
- State-of-the-art powder coat finish for maximum weatherability and scratch resistance.
- Self-closing lids ensure weatherproof protection when the receptacle is not in use.
- Includes gasket and mounting hardware for easy installation.

그림 1: 전면 view of the Hubbell 5874-5S Weatherproof Box with the cover open, revealing the integrated GFCI receptacle.
2. 안전 정보
경고: To avoid fire, shock, or death; turn off power at circuit breaker or fuse box and test that power is off before wiring! This device must be installed by a qualified electrician in accordance with all national and local electrical codes.
- 설치 또는 정비 전에 항상 전원을 차단하십시오.
- 제품이 손상된 것처럼 보이면 사용하지 마십시오.
- 모든 연결 부분이 안전하고 적절히 절연되어 있는지 확인하세요.
- This product is designed for outdoor use and must be installed in a location protected from direct water spray, as per local codes.
- 제안 65 경고: 이 제품에는 캘리포니아주에서 암과 선천적 기형 또는 기타 생식 기능 장애를 유발하는 것으로 알려진 화학 물질이 포함되어 있을 수 있습니다.
3. 설정 및 설치
- 설치 장소 준비: Ensure the electrical box or mounting surface is clean, dry, and free of debris. Turn off power at the main circuit breaker.
- Mount the Weatherproof Box: Position the weatherproof box over the existing electrical box or mounting surface. Use the included mounting hardware to securely fasten the box. Ensure the gasket is properly seated between the box and the mounting surface to maintain a watertight seal.
- Wire the GFCI Receptacle: Connect the electrical wires to the GFCI receptacle terminals. Refer to the wiring diagram on the GFCI unit itself. Typically, the "LINE" terminals connect to the incoming power from the circuit breaker, and the "LOAD" terminals (if used) connect to downstream receptacles or devices that also require GFCI protection. Ensure proper polarity (hot, neutral, ground).

그림 2: 후면 view of the GFCI receptacle, indicating LINE and LOAD terminals for wiring.
- Install the GFCI into the Box: Carefully fold the wires and insert the GFCI receptacle into the weatherproof box opening. Secure it with the provided screws.
- Close the Flip Cover: Ensure the self-closing flip cover operates smoothly and provides a tight seal when closed.
- 복원력 : 주 회로 차단기의 전원을 켜세요.
4. 사용 설명서
The integrated GFCI receptacle is designed for user safety. It continuously monitors the electrical current and will trip (shut off power) if it detects a ground fault, preventing electrical shock.
GFCI Self-Test Function:
This GFCI features an automatic self-test function. It periodically performs an internal test to ensure it is functioning correctly. If the GFCI fails the self-test, the indicator light will turn RED, and the unit will trip, indicating it needs replacement.
Manual Test and Reset:
- 테스트 버튼: Press the "TEST" button (usually black or red) to manually trip the GFCI. This should cause the power to the receptacle to shut off.
- 리셋 버튼: After testing or if the GFCI has tripped, press the "RESET" button (usually red or white) to restore power. If the GFCI does not reset, or trips immediately, there may be a ground fault or wiring issue that needs to be addressed.
Self-Closing Lids:
The flip cover features self-closing lids that automatically close when a plug is removed. This ensures continuous weatherproof protection for the receptacle when it is not in use.
5. 유지관리
- 정기 청소: Periodically clean the exterior of the weatherproof box with a damp 천. 연마성 세척제나 용매를 사용하지 마십시오.
- 월간 GFCI 테스트: It is recommended to manually test the GFCI monthly by pressing the "TEST" button and then the "RESET" button. This verifies its proper operation.
- 손상 여부 검사: Regularly inspect the box and cover for any signs of physical damage, cracks, or wear. Replace the unit if any damage is observed.
6. 문제 해결
- GFCI Will Not Reset:
가능한 원인: A ground fault exists in the circuit or connected appliance. The GFCI is faulty. Power is off to the circuit.
해결책: Unplug all appliances from the GFCI and any downstream outlets. Try to reset. If it resets, plug appliances back in one by one to identify the faulty appliance. If it still won't reset, check the circuit breaker. If the breaker is on and no appliances are connected, the GFCI may be faulty and needs replacement. Observe the indicator light: if it's RED, replacement is necessary.
- No Power to Receptacle:
가능한 원인: GFCI is tripped. Circuit breaker is off. Loose wiring connection.
해결책: Press the "RESET" button on the GFCI. Check the circuit breaker in your electrical panel. Ensure all wiring connections are secure (only perform if power is off and you are qualified).
7. 사양
| 특징 | 세부 사항 |
|---|---|
| 제품 유형 | 1-Gang, Complete Flip Cover Kit, Self Test GFCI, Flip Cover, Box, Receptacle |
| 모델 번호 | 5874-5S |
| 상표 | 벨 |
| 제조업체 | 허벨 |
| 색상 | 회색 |
| 재료 | 다이 캐스트 |
| 제품 치수 | 3.14 x 7 x 8.5 인치 |
| 품목 무게 | 5.44 온스 |
| 호환 장치 | All (standard electrical plugs) |
| 전원 플러그 유형 | A형 - 2핀 (북미식) |

Figure 3: Dimensions of the GFCI receptacle component.
8. 보증 및 지원
This BELL product is manufactured by Hubbell and is designed for durability and performance. For specific warranty information or technical support, please refer to the documentation included with your purchase or visit the official BELL/Hubbell web대지. 보증 청구를 위해 구매 영수증을 보관하십시오.
For further assistance, you may contact BELL customer service through their official channels.