1. 서론
Thank you for choosing the BESTTEN 1U PDU Rack Mount Power Strip. This unit is designed to provide reliable power distribution and surge protection for your electronic equipment, particularly in server racks or similar installations. Please read this manual thoroughly before installation and operation to ensure safe and optimal performance.
2. 안전 지침
- 전기 안전: Always connect the PDU to a properly grounded outlet. Do not remove the grounding prong.
- 과부하 보호: Do not exceed the maximum electrical rating of 15A/125V/1875W. Overloading can cause damage to the unit and connected devices, and may pose a fire hazard.
- 실내에서만 사용 가능: This product is intended for indoor use in dry locations. Do not expose to moisture or extreme temperatures.
- T를 피하세요amp어링: Do not attempt to open, modify, or repair the unit. Refer all servicing to qualified personnel.
- 코드 관리 : 전원 코드가 끼이거나 밟히거나 무거운 물체 아래에 놓이지 않도록 하십시오.
- 어린이와 애완동물: 어린이와 애완동물의 손이 닿지 않는 곳에 보관하세요.
3. 패키지 내용
- BESTTEN 1U PDU Rack Mount Power Strip (Model USM-0U8A-9C)
- 사용 설명서
Note: Mounting hardware (screws) may not be included and should be sourced separately if needed for your specific installation.
4. 제품 특징
- 8개의 AC 콘센트: 제공합니다 amp여러 장치를 위한 전원 연결.
- 9피트 전원 코드: Offers flexibility in placement and reach.
- 900줄 서지 보호: Safeguards connected electronics from power surges and spikes.
- Heavy-Duty Metal Housing: 까다로운 환경에도 견딜 수 있는 견고한 구조.
- 1U 랙 마운트형 디자인: Easily integrates into standard 19-inch server racks.
- Illuminated Power Switch: Controls power to all outlets and indicates operational status.
- ETL 목록: 안전 및 품질 기준 인증을 받았습니다.
5. 설정 및 설치
The BESTTEN 1U PDU is designed for versatile installation, including rack mounting or surface mounting.

Figure 1: BESTTEN 1U PDU Rack Mount Power Strip. This image displays the BESTTEN 1U PDU Rack Mount Power Strip. It features a black metal housing with eight standard AC outlets arranged linearly. A red illuminated power switch and a 'SurgePro' indicator are visible at one end. A coiled 9-foot power cord with a standard three-prong plug extends from the unit. Mounting brackets are visible at both ends for rack installation.
5.1 랙 마운팅
- Identify an available 1U space in your standard 19-inch server rack.
- Align the mounting brackets on both ends of the PDU with the rack posts.
- Secure the PDU to the rack using appropriate rack screws (not included). Ensure it is firmly attached.
5.2 Surface Mounting (e.g., under desk, wall)
- 설치할 평평하고 안정적인 표면을 선택하십시오.
- Use the mounting brackets on the PDU as a template to mark screw locations.
- 필요한 경우 시험용 구멍을 뚫습니다.
- Secure the PDU to the surface using appropriate screws (not included). Ensure it is firmly attached and stable.
5.3 전원 연결
- Once the PDU is securely mounted, plug its 9-foot power cord into a grounded 125V AC wall outlet.
- The power switch on the PDU should illuminate when power is supplied and the switch is in the 'ON' position.
6. 사용 설명서
6.1 전원 켜기/끄기
- To turn on the PDU and supply power to its outlets, press the red illuminated power switch to the 'ON' position. The switch will light up.
- To turn off the PDU and cut power to all connected devices, press the power switch to the 'OFF' position. The light will extinguish.
6.2 장치 연결
- Plug your electronic devices into the 8 AC outlets on the PDU.
- Ensure that the total power draw of all connected devices does not exceed the PDU's maximum rating of 1875W (15A at 125V).
6.3 서지 보호
This PDU includes 900 Joules of surge protection to shield your connected equipment from voltage spikes. In the event of a significant power surge, the surge protection feature will activate to absorb the excess energy. If the surge protection is compromised, the 'SurgePro' indicator light (if present and functional) may turn off or change color, indicating that the unit no longer provides surge protection. In such a case, the unit should be replaced.
7. 유지관리
- 청소: Disconnect the PDU from the power source before cleaning. Use a soft, dry cloth to wipe the exterior. Do not use liquid cleaners or aerosols.
- 점검: Periodically inspect the power cord and the PDU for any signs of damage, such as frayed wires, cracks, or loose connections. If damage is found, discontinue use and replace the unit.
- Outlet Caps: The unit may come with safety caps for unused outlets. Use these to prevent dust accumulation and accidental contact.
8. 문제 해결
| 문제 | 가능한 원인 | 해결책 |
|---|---|---|
| PDU has no power / Power switch light is off. |
|
|
| 연결된 기기에 전원이 공급되지 않고 있습니다. |
|
|
| 'SurgePro' indicator light is off. |
|
|
9. 사양
| 특징 | 세부 사항 |
|---|---|
| 모델 번호 | USM-0U8A-9C |
| 총 전원 콘센트 | 8 |
| 권tage 등급 | 125 볼트 |
| 현재 평가 | 15 Amps |
| 최대 전력 등급 | 1875 와트 |
| 서지 보호 | 900 줄 |
| 코드 길이 | 9 피트 |
| 제품 치수 | 19 x 1.75 x 1.75 인치 |
| 품목 무게 | 2.11파운드 |
| 재료 | 헤비 듀티 메탈 |
| 인증 | ETL 등록됨 |
10. 보증 및 지원
BESTTEN products are manufactured to high-quality standards. For specific warranty information, please refer to the warranty card included with your purchase or visit the official BESTTEN website. If you encounter any issues or have questions regarding your BESTTEN 1U PDU, please contact BESTTEN customer support for assistance.