AIMS Power PICOGLF20W12V120V

AIMS Power 2000 Watt 12V Pure Sine Inverter Charger Instruction Manual

Model: PICOGLF20W12V120V

1. 서론

This manual provides detailed instructions for the installation, operation, and maintenance of your AIMS Power 2000 Watt 12V Pure Sine Inverter Charger. This unit combines an inverter, battery charger, and AC auto-transfer switch into a single system, designed for various applications including renewable energy systems, utility backup, RVs, and emergency vehicles. Please read this manual thoroughly before installation and use to ensure safe and efficient operation.

2. 안전 정보

WARNING: Improper installation or operation can result in serious injury or death. Always follow safety guidelines.

  • Ensure proper DC input voltag이자형. 잘못된 권tage may permanently damage the inverter and void the warranty.
  • Do not block ventilation openings. The system is air-cooled, and a clearance of approximately 1 foot (30cm) is recommended around the unit for proper airflow.
  • Always connect the battery with correct polarity. Reverse polarity will cause damage.
  • Ensure all connections are secure to prevent loose connections, which can cause overheating and fire.
  • 이 장치에는 고용량tage. Do not attempt to open or service the unit unless you are a qualified technician.
  • Ground the unit properly according to local electrical codes.

3. 제품 특징

  • 강력한 출력: 2000W continuous pure sine wave power, with a 6000W surge capacity for 20 seconds.
  • 통합 충전기: 70A smart battery charger with multi-stage charging for 8 different battery technologies, including lithium.
  • Auto Transfer Switch: Seamless power transfer with approximately 10ms typical transfer time when utility or generator power is present.
  • 포괄적인 보호 조치: Includes overload, over-temperature, high voltag전자, 낮은 볼륨tage, short circuit, and internally fused protection. Features low and high voltag전자 알람.
  • 충전 전류 조절 가능: Charging current is adjustable from 0-100% for precise control over battery banks.
  • 절전 모드: Designed to conserve battery power by entering a search mode when AC loads are low or infrequent.
  • ETL 인증: Listed to UL 458 for land vehicles and marine crafts.
  • 편리한 기능: GFCI outlet, AC direct connect terminal block, charge current control dial, dip switches for priority settings, auto generator start functionality, and conformal coated components.

4. 구성 요소 이상view

Familiarize yourself with the various components and connection points of the inverter charger.

뒤쪽 view of AIMS Power Inverter Charger with labeled components

그림 4.1: 후면 패널 연결 및 제어
This image displays the rear panel of the AIMS Power Inverter Charger, highlighting key components such as the DC terminals (positive and negative), charge current control dial, on/off power switch, LCD remote port, dip switches, auto generator start terminal, optional battery temperature sensor port, and grounding DC terminal.

뒤쪽 view of AIMS Power Inverter Charger showing DC connections

Figure 4.2: Detailed DC Terminal View
A closer look at the rear panel, emphasizing the large positive and negative battery terminal connectors for 12 VDC or 24 VDC systems. Important warnings regarding battery polarity and proper cable lug installation are visible.

앞쪽 view of AIMS Power Inverter Charger showing AC output and input

Figure 4.3: AC Input and Output Connections
This image shows the side panel with the AC input and output connections, including the GFCI output receptacle and the hardwire terminal block for AC output. The ETL Listed mark is also visible.

4.1 Front Panel (Not explicitly shown in detail, but general controls)

  • 전원 스위치: Controls the main power to the inverter.
  • LED 표시등: Display operational status, fault conditions, and charging status.

4.2 Rear Panel (Refer to Figure 4.1 and 4.2)

  • DC Terminals: Large terminals for connecting to the 12V battery bank. Ensure correct polarity (Positive + and Negative -).
  • 접지 단자: For connecting the unit to an earth ground.
  • LCD Remote Port: For connecting an optional LCD remote display.
  • 딥 스위치: Used to configure various settings such as battery type, charge voltage, and power saver mode.
  • Charge Current Control Dial: Adjusts the battery charging current.
  • Auto Generator Start Terminal: For connecting to a compatible generator for automatic starting.
  • Battery Temp Sensor Port: For connecting an optional battery temperature sensor to optimize charging.

4.3 Side Panel (Refer to Figure 4.3)

  • AC 입력: Connection point for utility or generator AC power.
  • AC 출력: Connection point for AC loads.
  • GFCI Output: A standard AC outlet with Ground Fault Circuit Interrupter protection.
  • 회로 차단기: Protect AC output circuits.

5. 설정 및 설치

Proper installation is crucial for the safe and efficient operation of your inverter charger. If you are unsure about any step, consult a qualified electrician or technician.

5.1 장치 장착

  • Mount the inverter charger in a dry, well-ventilated area, away from direct sunlight, heat sources, and flammable materials.
  • Ensure at least 1 foot (30cm) of clearance around the unit for proper airflow and cooling.
  • Mount the unit securely to a stable surface using appropriate fasteners.

5.2 DC 배터리 연결

  • 배터리 유형: This unit is designed for 12V battery banks. Ensure your battery bank voltage는 인버터의 입력 전압과 일치합니다.tage.
  • 케이블 크기: Use appropriately sized cables for your battery connections to minimize voltage drop and ensure safety. Refer to electrical codes or a qualified professional for correct sizing.
  • 연결 순서:
    1. Connect the negative (-) battery cable to the negative (-) terminal on the inverter.
    2. Connect the positive (+) battery cable to the positive (+) terminal on the inverter.
    3. Connect the other end of the negative (-) cable to the negative (-) terminal of your battery bank.
    4. Connect the other end of the positive (+) cable to the positive (+) terminal of your battery bank.
  • 보안 연결: Ensure all connections are tight and secure. Loose connections can cause arcing and overheating.

5.3 AC Wiring Connections

  • AC 입력: Connect the utility grid or generator AC power to the AC input terminals. Ensure the input voltage and frequency are compatible with the inverter charger.
  • AC 출력: Connect your AC loads to the AC output terminals or use the GFCI outlet.
  • 접지: Connect the grounding terminal of the inverter charger to a reliable earth ground.
  • 회로 보호 : Ensure appropriate circuit breakers are installed on both AC input and output lines as per local electrical codes.

5.4 Remote Control and Sensor Connections (Optional)

  • LCD Remote: If using an optional LCD remote, connect it to the designated LCD remote port on the rear panel.
  • 배터리 온도 센서: If using an optional battery temperature sensor, connect it to the battery temp sensor port and attach the sensor to the battery bank for accurate temperature compensation during charging.
  • Auto Generator Start: Connect compatible auto generator start wiring to the designated terminal if this feature is desired.

6. 사용 설명서

6.1 초기 전원 켜기

  • After all connections are securely made and verified, switch on the DC power from the battery bank (if a disconnect switch is used).
  • Turn the main power switch on the inverter charger to the "ON" position.
  • Observe the LED indicators for normal operation. Refer to the troubleshooting section if any fault indicators illuminate.

6.2 Configuring Settings (Dip Switches)

The dip switches on the rear panel allow configuration of various operational parameters. Refer to the label on the unit or the full user manual for specific dip switch settings for battery type, charge voltage, and power saver mode. Ensure the unit is powered off before changing dip switch settings.

6.3 인버터 운전

  • When the unit is powered on and no AC input is present, the inverter will convert DC battery power to AC power for your connected loads.
  • 절전 모드: This mode reduces idle power consumption. When activated via dip switch, the inverter will periodically "search" for a load. If a load greater than 50W is detected, the inverter will fully activate. If no load is detected, it returns to low-power search mode.

6.4 충전기 작동

  • When external AC power (utility or generator) is connected to the AC input, the unit will automatically begin charging the battery bank.
  • Charge Current Control: Use the charge current control dial to adjust the charging amperage. This is useful for smaller battery banks or when using a generator with limited output.
  • 멀티에스tage 충전 중: 충전기는 다중 s를 사용합니다.tage charging process (bulk, absorption, float) to optimize battery health and lifespan.

6.5 AC Auto-Transfer Switch

  • When external AC power is detected at the input, the unit will automatically transfer the AC loads from inverter power to the external AC source. This transfer typically occurs within 10 milliseconds.
  • When external AC power is lost, the unit will automatically switch back to inverter power, drawing from the battery bank.

7. 유지관리

  • 정기 검사: Periodically inspect all wiring connections for tightness and corrosion. Clean any corrosion with a wire brush and baking soda solution.
  • 통풍: Ensure ventilation openings are clear of dust and debris. Clean with compressed air if necessary.
  • 배터리 유지 관리: Follow the manufacturer's recommendations for your specific battery type. This may include checking electrolyte levels for flooded lead-acid batteries.
  • 환경 조건: Keep the unit in a dry, cool environment. Avoid exposure to moisture, extreme temperatures, and corrosive fumes.

8. 문제 해결

This section addresses common issues you might encounter. For more complex problems, contact AIMS Power technical support.

8.1 No AC Output from Inverter

  • Check DC Connections: Ensure battery cables are securely connected and not corroded.
  • 배터리 용량tage: 배터리 용량 확인tage is within the operating range (e.g., above low voltage cut-off). Charge batteries if low.
  • 초과 적재: Disconnect some AC loads. The inverter may have shut down due to an overload.
  • 과열: Ensure adequate ventilation. Allow the unit to cool down if it has overheated.
  • 내부 퓨즈: If the unit is completely unresponsive, an internal fuse may have blown. This requires professional service.

8.2 배터리가 충전되지 않음

  • AC 입력: Verify that external AC power is present and connected to the inverter's AC input.
  • AC Input Breaker: Check if the AC input circuit breaker on the unit or external panel has tripped.
  • Charge Current Dial: Ensure the charge current control dial is not set to zero.
  • 배터리 유형 설정: Confirm dip switch settings match your battery type.

8.3 GFCI Outlet Trips Frequently

  • 접지 결함: A ground fault may exist in the connected appliance or wiring. Disconnect appliances one by one to identify the faulty one.
  • 초과 적재: The connected load might be exceeding the GFCI outlet's rating.

9. 사양

특징사양
모델PICOGLF20W12V120V
연속 와트tage2000 와트
서지 와트tage6000 Watts (20 seconds)
DC 입력 볼륨tage12 볼트
AC 출력 볼륨tage120 볼트
출력파형순수한 사인 웨이브
배터리 충전기 전류70 Amps(조정 가능)
전송 시간약 10ms
치수21 x 13.8 x 12.4 인치
품목 무게55파운드
인증ETL Certified to UL 458

10. 보증 및 지원

AIMS Power offers a 2년 보증 on this product. For technical assistance, warranty claims, or further information, please contact AIMS Power directly. All technical and warranty support is provided from their facility in Nevada, USA.

추가 리소스를 보려면 다음을 방문하세요. AIMS 파워 스토어 아마존에서 만나보세요.

관련 문서 - PICOGLF20W12V120V

사전view AIMS Power Global LF 시리즈 순수 정현파 인버터 충전기 사용 설명서
AIMS Power Global LF 시리즈 순수 정현파 인버터 충전기(PICOGLF10W12V120V, PICOGLF15W12V120V, PICOGLF20W12V120V, PICOGLF30W12V120V 모델)의 설치, 작동, 기능 및 문제 해결에 대한 자세한 사용자 설명서입니다.
사전view AIMS Power Global LF Series Pure Sine Wave Inverter/Charger User Manual
User manual for the AIMS Power Global LF Series Pure Sine Wave Inverter/Charger. Covers installation, operation, safety, key features like pure sine wave output, battery charging, automatic transfer, and applications in renewable energy, RVs, and vehicles.
사전view AIMS Power PWRI200012120S DC-AC 순수 사인파 전력 인버터 사용 설명서
AIMS Power PWRI200012120S 2000W 순수 사인파 전력 인버터의 사용 설명서로, 안전, 기능, 설치, 작동, 문제 해결, 사양 및 보증에 대한 내용을 다룹니다.
사전view AIMS Power PWRI200012120S 2000W 순수 정현파 인버터 사용 설명서
AIMS Power PWRI200012120S 2000W 순수 정현파 DC-AC 전력 인버터 사용 설명서입니다. 제품 소개, 안전 경고, 특징, 설치, 배터리 요구 사항, 연결, 작동, 보호 기능, 문제 해결, 사양 및 보증에 대한 내용을 다룹니다.
사전view AIMS Power Pure Sine Wave 인버터 작동 설명서 - 사양 및 가이드
AIMS Power 순수 사인파 인버터에 대한 포괄적인 작동 설명서로, PWRIG1000, PWRIG1500, PWRIG2000, PWRIG3000 시리즈 모델의 사양, 기능, 연결 다이어그램, 작동 절차, 문제 해결 및 안전 경고를 다룹니다.
사전view AIMS Power PWRI200012120S DC-AC 순수 사인파 전력 인버터 사용 설명서
This instruction manual provides comprehensive details for the AIMS Power PWRI200012120S DC to AC Pure Sine Power Inverter. It covers product introduction, essential safety warnings, key features, installation guidelines, battery requirements, connection procedures, operational instructions, built-in protections, troubleshooting tips, technical specifications, and warranty information.