1. 서론

The Simplex 4099-9005 is an addressable manual pull station designed for use with compatible Simplex fire alarm control panels. This dual-action device requires two distinct operations to activate, reducing the likelihood of accidental activation. It is an integral component of a comprehensive fire detection and alarm system, providing a manual means for occupants to initiate an alarm in the event of a fire or other emergency.

2. 안전 정보

중요 안전 지침:

3. 제품 오버view

The Simplex 4099-9005 is a red, dual-action manual pull station. Its addressable nature allows the fire alarm control panel to identify the exact location of the activated station. The dual-action design requires a two-step process for activation: first, pushing in a bar, and then pulling down a handle.

앞쪽 view of the Simplex 4099-9005 Addressable Manual Pull Station, showing the 'FIRE ALARM' label, 'PUSH BAR', and 'PULL HANDLE'.

그림 1: 전면 view of the Simplex 4099-9005 Addressable Manual Pull Station. This image displays the primary components including the 'FIRE ALARM' text, the 'PUSH BAR' mechanism, and the 'PULL HANDLE' for activation.

4. 설치

Proper installation is crucial for the reliable operation of the manual pull station.

4.1 장착

4.2 배선

4.3 주소 설정

The 4099-9005 is an addressable device. Before connecting to the SLC, set the unique address for the pull station using the appropriate Simplex programming tool or DIP switches, as specified in the device's technical documentation. Each device on the SLC must have a unique address.

옆 view of the Simplex 4099-9005 Addressable Manual Pull Station, showing its depth and mounting points.

그림 2: 측면 view of the Simplex 4099-9005 Addressable Manual Pull Station. This image illustrates the depth of the unit and provides a perspective on its mounting configuration.

5. 운영

5.1 알람 활성화

In the event of a fire or emergency, follow these steps to activate the manual pull station:

  1. 밀어 넣기: Firmly push the bar labeled "PUSH BAR" on the front of the station.
  2. 풀다운: Once the bar is pushed in, pull down the handle labeled "PULL HANDLE" until it latches in the down position.

Activation will send an alarm signal to the fire alarm control panel, initiating the building's alarm sequence.

5.2 풀 스테이션 재설정

After an alarm has been activated and the emergency resolved, the pull station must be reset. The Simplex 4099-9005 requires a B-Key for resetting.

  1. Insert B-Key: Locate the keyhole on the front of the pull station. Insert the B-Key into the keyhole.
  2. 턴키 방식: Turn the B-Key clockwise or counter-clockwise (depending on the specific mechanism) to release the latched handle.
  3. 덮개 닫기: Return the handle to its original, unactivated position and close the front cover.
  4. Remove B-Key: Remove the B-Key.

The B-Key is considered a tool for maintenance and resetting, not a consumable item. If additional B-Keys are required, they can be ordered using PID: 252-019.

6. 유지관리

정기적인 유지보수를 통해 Simplex 4099-9005 비상벨 작동기의 지속적인 신뢰성을 확보할 수 있습니다.

7. 문제 해결

If you encounter issues with your Simplex 4099-9005 pull station, consider the following:

For persistent issues, contact a qualified fire alarm technician.

8. 사양

특징사양
상표심플렉스
모델 번호4099-9005
스타일안전
전원수동
품목 무게3.53온스(100그램)
경보 종류Audible (via FACP)
재료Glass (referring to break-glass type, though this model is dual-action)
제품 치수1 x 3.4 x 5 인치
한국어:643485652991
부품 번호S4099-9005
필요한 배터리아니요

9. 보증 정보

Specific warranty details for the Simplex 4099-9005 Addressable Manual Pull Station are typically provided at the point of purchase or can be obtained directly from Simplex or an authorized distributor. Please retain your proof of purchase for warranty claims. For detailed warranty terms and conditions, refer to the official Simplex documentation or contact their customer service.

10. 고객 지원

For technical assistance, installation queries, or service requests, please contact your authorized Simplex dealer or a certified fire alarm technician. Ensure you have the product model number (4099-9005) and any relevant system information available when seeking support.

관련 문서 - 4099-9005

사전view Simplex IDNet/MAPNET II 주소 지정 가능 수동 화재 경보 스테이션 - 제품 데이터
IDNet 및 MAPNET II 시스템과 호환되는 Simplex 4099 시리즈 주소 지정형 수동 화재 경보 스테이션에 대한 자세한 정보입니다. 단동, 복동(유리 파손 및 푸시), 노그립(NO GRIP) 옵션을 포함한 다양한 모델의 기능, 사양, 장착 옵션 및 제품 구성을 제공합니다. ADA 요건을 준수하며 UL, ULC, FM, CSFM 인증을 받았습니다.
사전view 심플렉스 어드레서블 수동 스테이션: IDNet/MAPNET II 주변 장치
심플렉스 어드레서블 수동 화재 경보 스테이션의 특징, 단동/복동 작동 방식, NO GRIP 옵션, IDNet/MAPNET II 시스템과의 호환성 등을 자세히 살펴보세요. 설치 및 사양 정보도 포함되어 있습니다.
사전view 심플렉스 2099 시리즈 단동식 및 복동식 수동 화재 경보기 사양표
심플렉스 2099 시리즈 비코딩, 비주소 지정식 수동 화재 경보 발신기 제품 데이터시트입니다. 특징, 작동 방식, 적용 사례, 제품 선택, 설치 옵션 및 사양을 다룹니다.
사전view Simplex 4010ES: 소멸 자동 명령 시스템
가이드 기술 Simplex 4010ES 세부 사항 모듈 de commande pour les systèmes d'extinction automatique par gicleurs, couvrant les mode déluge et préventif, avec 사양, 승인 및 스키마 드 케이블.
사전view Simplex 4099-9801C IDNet™ 2-Stage Station IAM Installation Instructions
Installation instructions for the Simplex 4099-9801C IDNet™ 2-Stage Station Individual Addressable Module (IAM). Covers mechanical installation, electrical connections, and address configuration for fire alarm systems.
사전view 심플렉스 4004 화재 경보 제어 패널: 설치 및 작동 지침
심플렉스 4004 화재 경보 제어 패널(FACP)의 설치, 작동 및 프로그래밍에 대한 종합 가이드입니다. 시스템 전반에 대한 설명도 포함되어 있습니다.view요구 사항, 배선, 모듈 설명 및 문제 해결 방법.