1. 서론
This manual provides essential information for the safe and effective operation of your OWON SDS6062 Digital Storage Oscilloscope. Please read this manual thoroughly before using the device to ensure proper setup, operation, and maintenance. The SDS6062 is a 2-channel oscilloscope featuring a 60 MHz bandwidth, 500 MS/s sample rate, and a 10M record length, designed for precise electrical signal analysis.
2. 안전 정보
Always observe the following safety precautions to prevent injury and avoid damage to the instrument or any connected products. Read these instructions carefully before operation.
- 전원: Use only the power adapter supplied with the instrument. Ensure the voltage는 귀하의 지역 전원 공급 장치와 일치합니다.
- 접지: The oscilloscope must be properly grounded to prevent electric shock.
- 프로브 안전: Do not connect the probe ground lead to a point where a voltage greater than 30V RMS or 42.4V peak is present.
- 환경: Operate the device in a well-ventilated area, away from moisture, dust, and direct sunlight. Avoid operating in explosive atmospheres.
- 유지: 모든 정비는 자격을 갖춘 서비스 담당자에게 맡기십시오. 직접 수리하려고 하지 마십시오.
3. 패키지 내용
Verify that all items listed below are present in your package. If any items are missing or damaged, contact your supplier.
- OWON SDS6062 Digital Storage Oscilloscope Unit
- 오실로스코프 프로브 2개
- 1 X 전원 코드
- 1 x Probe Adjust Pen
- 1 x USB 데이터 케이블
- 1 x 소프트웨어 CD
- 1 x 사용자 매뉴얼(이 문서)
4. 제품 오버view
The OWON SDS6062 is a compact and powerful digital storage oscilloscope. It features an 8-inch (800x600) color TFT-LCD screen for clear waveform display and an intuitive control panel for easy operation. Key features include its 60 MHz bandwidth, 500 MS/s real-time sample rate, and 10M record length, making it suitable for a wide range of applications.

그림 4.1: 전면 view of the OWON SDS6062 Digital Storage Oscilloscope, showing the display, control knobs, and function buttons.
4.1 전면 패널 컨트롤
The front panel includes the main display, vertical controls (VOLTS/DIV, position), horizontal controls (SEC/DIV, position), trigger controls, and various function buttons for menu navigation, measurement, and utility settings.
4.2 후면 패널 연결
The rear panel provides connectivity options including the power input, USB host and device ports, LAN port for network connectivity, and a VGA port for external display output.
5. 설정
Follow these steps to set up your OWON SDS6062 oscilloscope for initial use.
5.1 전원 연결
- Ensure the oscilloscope is turned off.
- Connect the supplied power cord to the power input on the rear panel of the oscilloscope.
- 전원 코드의 다른 쪽 끝을 접지된 AC 전원 콘센트에 꽂습니다.
5.2 프로브 연결
- Align the BNC connector of the probe with the CH1 or CH2 input on the front panel.
- Push and twist the connector clockwise until it locks into place.
- Attach the probe ground clip to the ground terminal of the circuit under test.
- Set the probe attenuation switch (e.g., 1X or 10X) to match the setting on the oscilloscope's input channel menu.
5.3 초기 전원 켜기
- 전면 패널에 있는 전원 버튼을 누릅니다.
- The oscilloscope will perform a self-test and display the startup screen.
- After startup, it is recommended to perform a probe compensation adjustment (refer to Section 7.3).
6. 오실로스코프 작동법
This section covers basic operation and common functions of the SDS6062.
6.1 기본 측정
To display a signal:
- Connect a signal source to CH1 or CH2 using a probe.
- 를 누르세요 자동 설정 버튼을 누르면 오실로스코프가 수직, 수평 및 트리거 설정을 자동으로 조정하여 안정적인 파형을 표시합니다.
- 조정하다 볼트/DIV 수직 스케일(볼륨)을 변경하는 노브tage 부서당).
- 조정하다 초/DIV 수평 스케일(구획당 시간)을 변경하는 노브입니다.
- Use the vertical and horizontal 위치 knobs to move the waveform on the screen.
6.2 트리거 시스템
트리거 시스템은 반복적인 파형을 안정화하고 단일 샷 이벤트를 포착합니다.
- 트리거 레벨: 사용하세요 트리거 레벨 볼륨을 조절하는 노브tage level at which the trigger occurs.
- 트리거 모드 : Access the trigger menu to select modes like Edge, Pulse, Video, or Slope.
- 트리거 소스: Select the input channel (CH1, CH2, EXT, AC Line) that will be used for triggering.
6.3 측정 함수
The SDS6062 offers various automatic measurement functions.
- 를 누르세요 측정하다 button to display the measurement menu.
- Select desired measurements such as Vpp, Vmax, Vmin, Freq, Period, Rise Time, etc.
6.4 Connectivity (LAN and VGA)
- LAN : Connect an Ethernet cable to the LAN port on the rear panel to connect the oscilloscope to a network. This allows for remote control and data transfer using compatible software.
- VGA : Use the VGA port to connect an external monitor or projector for larger display of waveforms, useful for presentations or collaborative work.
7. 유지관리
적절한 유지 관리는 오실로스코프의 수명과 정확성을 보장합니다.
7.1 청소
Clean the instrument regularly with a soft, damp 천을 사용하십시오. 연마성 세제나 용제를 사용하지 마십시오. 천이 손상될 수 있습니다.asin화면 또는 플러그를 뽑으십시오. 청소하기 전에 기기의 전원이 꺼져 있고 플러그가 뽑혀 있는지 확인하십시오.
7.2 보관
When not in use, store the oscilloscope in a dry, dust-free environment, away from extreme temperatures and direct sunlight. Use the original packaging or a suitable carrying case for protection during transport.
7.3 Probe Compensation Adjustment
Probe compensation should be adjusted to match the oscilloscope's input characteristics. This ensures accurate measurements.
- Connect the probe to CH1 and attach the probe tip to the probe compensation output (usually a square wave test point on the front panel).
- 프로브 접지 클립을 접지 단자에 연결하십시오.
- 누르다 자동 설정.
- Use the supplied probe adjust pen to turn the trimmer screw on the probe until the square wave displayed on the screen has flat top and bottom edges (no overshoot or undershoot).
8. 문제 해결
이 섹션에서는 일반적으로 발생할 수 있는 문제에 대한 해결책을 제공합니다.
- 디스플레이 없음: Check power connection, ensure the power button is pressed. Adjust screen brightness if necessary.
- No Waveform: Verify probe connection to the input channel and the circuit under test. Ensure the signal source is active. Press 자동 설정. Check vertical and horizontal scale settings.
- 불안정한 파형: Adjust the trigger level. Check trigger mode and source settings. Ensure the signal is within the oscilloscope's bandwidth.
- 부정확한 측정: Perform probe compensation adjustment (Section 7.3). Ensure probe attenuation settings match the oscilloscope.
- 장치가 응답하지 않음: Try restarting the oscilloscope. If the issue persists, contact technical support.
9. 사양
Technical specifications for the OWON SDS6062 Digital Storage Oscilloscope.
| 매개변수 | 사양 |
|---|---|
| 모델 번호 | SDS6062 |
| 대역폭 | 60MHz |
| 채널 | 2 + 1 (External Trigger) |
| Sample Rate (Real-time) | 500MS/초 |
| 레코드 길이 | 10만 포인트 |
| 표시하다 | 8-inch Color TFT-LCD (800x600) |
| 인터페이스 | USB Host, USB Device, LAN, VGA |
| AutoScale Function | 예 |
| 제조업체 | 오원 |
10. 보증 및 지원
OWON products are designed for reliability and performance. For warranty information, please refer to the warranty card included with your product or visit the official OWON website. For technical support, troubleshooting assistance, or service inquiries, please contact your local OWON distributor or the OWON customer service department. Keep your purchase receipt as proof of purchase for warranty claims.