1. 제품 오버view
The Legrand 138074 is a manual call point designed for fire alarm systems. It features a white housing, two contacts, and an integrated LED indicator. This device allows for manual activation of a fire alarm in emergency situations, providing a clear visual and tactile indication of activation.
그림 1: 전면 view of the Legrand 138074 Manual Call Point.
2. 안전 정보
이 장치를 설치하거나 작동하기 전에 모든 안전 지침을 읽고 이해하십시오. 이 지침을 따르지 않을 경우 재산 피해, 부상 또는 사망으로 이어질 수 있습니다.
- 전문적인 설치: Installation must be performed by qualified personnel in accordance with all local and national electrical codes and fire safety regulations.
- 전원 차단: Always disconnect power to the circuit before performing any installation, maintenance, or troubleshooting.
- 권tage 확인: 전원 공급 장치의 볼륨을 확인하십시오.tage는 기기의 사양과 일치합니다.
- 환경 조건: Do not install in areas with excessive moisture, extreme temperatures, or corrosive environments.
- 구성 요소 무결성: 부품이 손상된 경우에는 기기를 사용하지 마십시오.
3. 패키지 내용
패키지를 열 때 모든 구성 요소가 들어 있고 손상되지 않았는지 확인하세요.
- Legrand 138074 Manual Call Point (1 unit)
- 장착 나사 (제공된 수량 그대로)
- 사용 설명서(본 문서)
4. 설정 및 설치
The Legrand 138074 Manual Call Point is designed for surface or flush mounting. Ensure the chosen location complies with local fire safety regulations regarding accessibility and visibility.
4.1. 장착
- 장착 표면 준비: Ensure the surface is clean, dry, and flat.
- 드릴링 지점 표시: Use the call point's base as a template to mark the positions for mounting screws.
- 드릴 구멍: 장착 나사에 적합한 크기의 드릴로 예비 구멍을 뚫으세요.
- 기지를 확보하세요: Attach the call point's base securely to the wall using the provided screws.
4.2. 배선
Refer to the wiring diagram below and your fire alarm control panel's documentation for correct connection. This device features 2 contacts and an LED indicator.
- Connect the alarm circuit wires to the designated terminals (typically NO/NC contacts).
- Connect the LED indicator wires to the appropriate power source and signaling circuit as per your system's requirements.
- 모든 연결 부분이 안전하고 적절히 절연되어 있는지 확인하세요.
그림 2: 내부 view and wiring terminals of the Legrand 138074 Manual Call Point.
4.3. 최종 조립
- Carefully place the front cover onto the mounted base, ensuring all wires are tucked away and not pinched.
- Secure the cover with any retaining screws or clips provided.
- Restore power to the circuit and test the device according to your fire alarm system's testing procedures.
5. 사용 설명서
In the event of a fire or other emergency requiring immediate alarm activation:
- Locate the Call Point: Identify the nearest Legrand 138074 Manual Call Point.
- 알람을 활성화하세요: Firmly press the designated activation area on the call point. This action will typically break a frangible element or activate a switch.
- 활성화 확인: The integrated LED indicator should illuminate, confirming that the call point has been activated and the signal sent to the fire alarm control panel.
- 대피: Follow your building's emergency evacuation procedures.
Note: Resetting the call point typically requires a special key or tool to return the activation mechanism to its original state after an alarm. Consult your fire alarm system administrator for reset procedures.
6. 유지관리
Regular maintenance ensures the reliable operation of your manual call point.
- 시각적 검사: Periodically inspect the call point for any signs of physical damage, tampering, or obstruction. Ensure the LED is functional during system tests.
- 청소: Clean the exterior of the call point with a soft, damp 천. 연마성 세척제나 용매를 사용하지 마십시오.
- 기능 테스트: Conduct regular functional tests as required by local fire safety regulations and your fire alarm system's maintenance schedule. This should be performed by qualified personnel.
- 구성 요소 교체: If the frangible element is broken or the device is damaged, it must be replaced by a qualified technician.
7. 문제 해결
If you encounter issues with your Legrand 138074 Manual Call Point, refer to the table below. For problems not listed, contact qualified service personnel.
| 문제 | 가능한 원인 | 해결책 |
|---|---|---|
| LED not illuminating upon activation | Incorrect wiring for LED; LED faulty; No power to LED circuit. | Check LED wiring connections; Test LED circuit for power; Replace call point if LED is faulty. |
| Alarm not activating when call point is pressed | Incorrect wiring for contacts; Contacts faulty; Issue with fire alarm control panel. | Verify contact wiring; Test continuity of contacts; Consult fire alarm control panel manual or technician. |
| Call point appears damaged | Physical impact; Vandalism. | Replace the damaged call point immediately. |
8. 사양
| 특징 | 세부 사항 |
|---|---|
| 제조업체 | 르그랑 |
| 모델 번호 | 138074 |
| 제품 유형 | 수동 콜 포인트 |
| 색상 | 하얀색 |
| 콘택트 렌즈 | 2개의 연락처 |
| 지시자 | 통합 LED |
| 제품 무게 | 0.05g |
| ASIN | B018PB4SP8 |
| 첫 번째 가능한 날짜 | 19년 2016월 XNUMX일 |
9. 보증 정보
Legrand products are manufactured to high standards and are typically covered by a limited warranty against defects in materials and workmanship. The specific warranty period and terms may vary by region and product type. Please retain your proof of purchase. For detailed warranty information, refer to the official Legrand website or contact Legrand customer support in your region.
10. 지원 및 연락처
For technical assistance, product inquiries, or to report issues, please contact Legrand customer support. You can find contact information, including phone numbers and online support portals, on the official Legrand web대지: