오닉스 3200

3200 자동/수동 팽창식 PFD 사용 설명서용 Onyx 재무장 키트

1. 서론

This instruction manual provides essential information for the proper use, installation, and maintenance of the Onyx Re-Arm Kit, model 3200. This kit is designed specifically for Onyx automatic/manual inflatable personal flotation devices (PFDs) that require a 24-gram CO2 cylinder. Adhering to these instructions ensures the continued safety and functionality of your inflatable PFD.

2. 제품 오버view 및 구성 요소

The Onyx Re-Arm Kit 3200 contains the necessary components to restore your inflatable PFD to an operational state after it has been deployed or if components require replacement due to expiration or damage.

키트 내용:

Onyx Re-Arm Kit components: a gold-colored CO2 cylinder, a yellow bobbin, and a green indicator clip.

This image displays the three primary components of the Onyx Re-Arm Kit: a 24-gram CO2 cylinder with a threaded neck, a yellow water-soluble bobbin, and a green indicator clip. These parts are crucial for the proper function of an automatic/manual inflatable PFD.

3. Setup and Installation (Re-Arming Instructions)

Before re-arming, ensure your PFD is completely deflated and dry. Always refer to your specific Onyx PFD's instruction manual for detailed re-arming procedures, as steps may vary slightly by model. The following are general guidelines.

General Re-Arming Steps:

  1. Remove Used Components: If the PFD has been deployed, carefully remove the spent CO2 cylinder by unscrewing it. Discard the old cylinder. Remove any old bobbin or indicator clips.
  2. Inspect PFD: Thoroughly inspect the PFD for any damage, tears, or punctures. Ensure the inflation bladder is intact and the oral inflation tube cap is secure.
  3. Install New Bobbin (for Automatic PFDs): Locate the automatic inflation mechanism. Insert the new yellow water-soluble bobbin into the designated slot. Ensure it is seated correctly according to your PFD's manual. This bobbin dissolves in water, triggering automatic inflation.
  4. Install New CO2 Cylinder: Carefully screw the new 24-gram CO2 cylinder into the inflation mechanism. Turn clockwise until it is hand-tight. 너무 조이지 마세요. Ensure the cylinder is fully seated.
  5. Install Green Indicator Clip: Attach the green indicator clip to the inflation mechanism. This clip typically confirms that the PFD is armed and ready for use. Refer to your PFD manual for the exact placement.
  6. Repack PFD: Once re-armed, carefully fold and repack the PFD according to its original instructions. Ensure the pull-cord for manual inflation is accessible and not obstructed.

중요한: Always ensure the CO2 cylinder is new and undamaged. Never use a cylinder that has been punctured or shows signs of corrosion.

4. Operating the Re-Armed PFD

After re-arming, your Onyx PFD is ready for use. It offers both automatic and manual inflation capabilities.

Always ensure the PFD is worn correctly and securely before engaging in water activities.

5. 유지관리 및 검사

Regular inspection and proper maintenance are crucial for the reliability of your inflatable PFD and its re-arm kit components.

Replace the re-arm kit components immediately after each inflation or if any component is damaged or expired.

6. 문제 해결

This section addresses common issues related to the re-arm kit and PFD inflation.

문제가능한 원인해결책
PFD does not inflate automatically.Bobbin is expired or incorrectly installed. Not enough water exposure.Check bobbin expiration date and installation. Ensure full submersion. Manually inflate if necessary.
PFD does not inflate manually.CO2 cylinder is not properly seated, is empty, or expired. Pull cord not activated.Ensure cylinder is hand-tight. Check green indicator. Replace cylinder if empty/expired. Pull cord firmly.
PFD inflates accidentally.Bobbin exposed to moisture. Manual pull cord snagged.Keep PFD dry when not in use. Ensure pull cord is not exposed or snagged during wear or storage.
PFD loses air after inflation.Puncture in bladder. Loose oral inflation cap.Perform leak test. Inspect bladder for damage. Tighten oral inflation cap. If damaged, PFD may need professional repair or replacement.

7. 사양

8. 보증 및 지원

For specific warranty information regarding your Onyx Re-Arm Kit or PFD, please refer to the documentation included with your original PFD purchase or visit the official Onyx Outdoor website. For technical support or inquiries, please contact Onyx Outdoor customer service directly.

메모: Using non-Onyx approved re-arm kits or components may void your PFD's warranty and compromise its safety performance.

관련 문서 - 3200

사전view Onyx RCR GT 41Ah 배터리 빠른 시작 가이드
이 필수 빠른 시작 가이드를 통해 Onyx RCR GT 41Ah 배터리를 신속하게 설치하고 작동시켜 보세요. 설치 방법, 블루투스 연결 방법, 그리고 최적의 성능을 위한 Onyx BMS 앱 사용법을 알아보세요.
사전view Onyx Healthcare 2024 카탈로그: 의료 AI 혁신 발전
Onyx Healthcare 2024 카탈로그를 살펴보세요. AI 지원 PC, 의료용 카트 컴퓨터, 태블릿, 그리고 향상된 환자 관리 및 운영 효율성을 위해 설계된 디스플레이 등 최첨단 의료 AI 하드웨어를 선보입니다. 디지털 수술실 및 첨단 의료 영상 솔루션을 확인해 보세요.
사전view Onyx 벽난로 리모컨: 기능 및 작동 가이드
Onyx 벽난로 리모컨을 작동하는 방법에 대한 자세한 가이드로, 리젠시 벽난로의 버튼 기능, 화염 설정, 난방 제어 및 타이머 기능을 설명합니다.
사전view BOOX Note3 Uživatelský 매뉴얼 - Návod k použití
Onyx International의 BOOX Note3에 대한 Kompletní uživatelský 매뉴얼. funkcích에 대한 정보, příslušenství, bezpečnostních pokynech 및 특정 항목에 대한 정보입니다.
사전view ONYX DX15 배터리 자동 스크러버 작동 설명서
ONYX DX15 배터리 자동 세척기 사용 설명서는 작동, 유지보수, 안전, 문제 해결 및 기술 사양을 포함한 포괄적인 내용을 담고 있습니다. 안전하고 효과적인 사용을 위한 자세한 지침이 포함되어 있습니다.
사전view 오닉스 밀라조 가구 설치 설명서
Avanti 110RW 벽난로와 함께 사용하도록 설계된 Onyx Milazzo 가구의 종합 설치 가이드입니다. 안전 경고, 부품 목록 및 단계별 조립 지침이 포함되어 있습니다.