ELKO EP HRN-55N

ELKO EP HRN-55N Phase Sequence Monitoring Relay

사용자 설명서

1. 소개 및 이상view

The ELKO EP HRN-55N is a sophisticated electronic relay designed for continuous monitoring of phase sequence and phase loss in three-phase electrical systems. This device is crucial for protecting sensitive equipment, such as motors, pumps, and compressors, from damage caused by incorrect phase rotation or the complete absence of one or more phases. It ensures the correct operation and longevity of machinery by disconnecting the load when an anomaly is detected.

This manual provides comprehensive instructions for the safe installation, operation, and maintenance of the HRN-55N relay. Please read this manual thoroughly before installation and operation to ensure proper functionality and to prevent potential hazards.

Safety Warning: Installation and servicing must be performed by qualified personnel only, in accordance with all local and national electrical codes and regulations. Disconnect all power before working on the device.

Note: No product images or videos were provided for this manual. Please refer to the product packaging or manufacturer's website for visual aids.

2. 설정 및 설치

2.1 장착

The HRN-55N relay is designed for DIN rail mounting (EN 60715). Ensure the mounting location is free from excessive vibration, moisture, dust, and corrosive gases. Maintain adequate ventilation around the device to prevent overheating.

  1. Securely attach the DIN rail to a stable surface within an electrical enclosure.
  2. Clip the HRN-55N relay onto the DIN rail by aligning the bottom clips and pressing the top edge until it locks into place.

2.2 배선

Before wiring, ensure the main power supply to the circuit is disconnected and locked out. Refer to the wiring diagram typically found on the side of the device or in the product datasheet for precise terminal connections. The HRN-55N typically requires connection to all three phases (L1, L2, L3) and a neutral (N) if applicable, for its monitoring function, and also has output relay contacts (e.g., 15, 16, 18) for controlling the load.

  • Connect the three-phase supply lines (L1, L2, L3) to the corresponding input terminals on the HRN-55N.
  • If the device requires a neutral connection, connect the neutral line to the designated terminal.
  • Connect the load control circuit to the output relay contacts. These contacts are typically Normally Open (NO) and Normally Closed (NC), and a Common (COM) terminal. For most applications, the NO contact is used to energize a contactor coil, which then supplies power to the protected equipment.
  • 접촉 불량 및 아크 발생 가능성을 방지하기 위해 모든 연결부가 단단히 고정되었는지 확인하십시오.

Important: Incorrect wiring can damage the device or the connected equipment, and poses a severe electrical hazard.

3. 사용 설명서

Once properly installed and wired, the HRN-55N operates automatically to monitor the phase conditions.

3.1 Power-Up and Initial Operation

  1. After completing all wiring, restore power to the circuit.
  2. The HRN-55N will perform a self-check. The status LED (typically green) will illuminate if all phases are present and in the correct sequence.
  3. If the phase sequence is correct and no phase loss is detected, the output relay will energize (the NO contact will close), allowing power to the protected equipment.

3.2개의 표시등 LED

The HRN-55N typically features one or more LEDs to indicate its operational status:

  • Green LED (Power/Status):
    • Solid ON: All phases present, correct sequence, relay energized.
    • OFF: No power, or internal fault.
    • Flashing: (Specific to model, may indicate a delay or specific fault condition).
  • Red LED (Fault/Error): (있는 경우)
    • Solid ON: Phase loss or incorrect phase sequence detected, relay de-energized.

3.3 Phase Sequence and Loss Detection

The HRN-55N continuously monitors the voltage and phase angle of each connected phase. If the phase sequence (L1-L2-L3) is incorrect, or if any phase voltage drops below a preset threshold (phase loss), the relay will immediately de-energize its output contacts, thereby protecting the connected load. The relay will automatically reset and re-energize once the correct phase conditions are restored.

4. 유지관리

The ELKO EP HRN-55N relay is designed for long-term, maintenance-free operation. However, periodic inspection of the installation environment is recommended.

  • 청소: Ensure the device is free from dust and debris. Use a soft, dry cloth for cleaning. Do not use liquid cleaners or solvents.
  • 사이: Periodically check terminal connections for tightness, especially in environments with vibration. Loose connections can lead to overheating and malfunction.
  • 환경 조건: 작동 환경이 지정된 온도 및 습도 범위 내에 있는지 확인하세요.

Note: There are no user-serviceable parts inside the HRN-55N. Do not attempt to open or repair the device. Doing so will void the warranty and may pose a safety risk.

5. 문제 해결

If the HRN-55N is not functioning as expected, refer to the following troubleshooting guide:

징후가능한 원인해결책
Device has no power (LEDs off).입력 볼륨 없음tage; incorrect wiring; blown fuse in supply circuit.입력 볼륨 확인tage at terminals; verify wiring against diagram; check and replace fuses.
Green LED off, Red LED (if present) on, or relay not energizing.Incorrect phase sequence; phase loss detected; voltage outside operating range.Verify phase sequence (L1, L2, L3) at input terminals; check for missing phases; measure line voltages. Correct any issues.
Relay cycles on/off rapidly.불안정한 입력 볼륨tage; intermittent phase loss.Check power supply stability; inspect wiring for loose connections; consult with an electrician to diagnose power quality issues.
Relay energized, but load not receiving power.Fault in load circuit; contactor coil failure; wiring error to load.Check the load circuit and contactor; verify wiring from HRN-55N output to contactor coil.

If the problem persists after following these steps, contact ELKO EP technical support or a qualified electrician.

6. 사양

The following are typical specifications for the ELKO EP HRN-55N. Refer to the specific product datasheet for exact values, as specifications may vary slightly by production batch or region.

  • 기능: Phase sequence and phase loss monitoring
  • 공급량tage: 3x 400V AC (L1, L2, L3) or 3x 230V AC (L1, L2, L3) depending on model variant.
  • 빈도: 50/60Hz
  • 출력 접점: 1x Changeover (SPDT) relay, typically 8A / 250V AC (resistive load)
  • 작동 온도: -20°C ~ +55°C (-4°F ~ +131°F)
  • 보관 온도: -30°C ~ +70°C (-22°F ~ +158°F)
  • 보호 등급: IP20 (terminals), IP40 (front panel)
  • 설치: DIN 레일 EN 60715
  • 치수(폭 x 높이 x 깊이): Approximately 90 x 17.6 x 64 mm (1-module width)
  • 무게: 약 60g

7. 보증 정보

ELKO EP products are manufactured to the highest quality standards. This product is covered by a standard manufacturer's warranty against defects in materials and workmanship for a period typically specified at the point of purchase or on the official ELKO EP website. The warranty does not cover damage resulting from improper installation, misuse, unauthorized modification, or natural disasters.

For detailed warranty terms and conditions, please refer to the official ELKO EP warranty policy available on their web사이트를 방문하거나 현지 유통업체에 문의하세요.

8. 지원 및 연락처

For technical assistance, product inquiries, or support regarding the ELKO EP HRN-55N relay, please contact your authorized ELKO EP distributor or visit the official ELKO EP web대지.

ELKO EP Official Web대지: www.elkoep.com

Please have your product model number (HRN-55N) and any relevant details about your installation or issue ready when contacting support.

관련 문서 - HRN-55N

사전view ELKO EP HRN 시리즈 다기능 볼륨tage 모니터링 릴레이 | 기술 데이터시트
ELKO EP의 HRN 시리즈 다기능 볼륨에 대한 상세 기술 데이터시트tag모니터링 릴레이. 단상 AC/DC 회로의 사양, 기능 및 응용 분야를 다룹니다.
사전view ELKO EP PRI-51 전류 모니터링 릴레이 - 기술 사양
ELKO EP PRI-51 전류 모니터링 릴레이의 자세한 기술 사양, 기능 및 배선도를 제공합니다. 전기 모니터링을 위한 특성, 기능 및 응용 분야에 대해 알아보세요.
사전view ELKO EP HRF-10 주파수 모니터링 릴레이 기술 사양
ELKO EP HRF-10 주파수 모니터링 계전기의 기술 사양 및 기능 설명입니다. 특성, 연결 다이어그램, 부하 유형, 기술 매개변수 및 AC 전압에 대한 작동 경고를 포함한 세부 정보가 제공됩니다.tag산업 및 태양광 발전 분야에서의 전자 모니터링.
사전view ELKO EP 모듈형 전자 장치 기술 카탈로그
다양한 모듈형 전자 장치를 갖춘 ELKO EP 기술 카탈로그를 살펴보세요. 이 가이드에는 시간 릴레이, 전원 공급 장치, 조광기, 모니터링 릴레이, 스마트 홈 솔루션 등 산업 및 주거용 전기 설비에 필수적인 다양한 제품이 자세히 설명되어 있습니다.
사전view ELKO EP 모듈형 전자 장치 기술 카탈로그
시간 릴레이, 조광기, 전원 공급 장치, 모니터링 릴레이 등을 포함한 모듈형 전자 장치로 구성된 ELKO EP 카탈로그를 살펴보세요. 주거, 상업 및 산업 분야의 최신 전기 설비에 필수적인 부품입니다.
사전view ELKO EP 관련: Modulové elektronické přístroje
시간 릴레이, 모니터링 릴레이 등 다양한 ELKO EP 모듈형 전자 장치를 살펴보세요. 전기 설비를 위한 혁신적인 솔루션을 발견하세요.