Lennox 83M00 LB-109531A

Lennox 83M00 LB-109531A Sure Light 교체 키트 사용 설명서

Model: 83M00 LB-109531A

소개

This manual provides essential instructions for the proper installation, operation, and maintenance of the Lennox 83M00 LB-109531A Sure Light Replacement Kit. This kit contains all components required to replace an existing single-stage SureLight® ignition control in a Lennox gas furnace. Adherence to these instructions is crucial for safe and efficient operation.

안전 정보

경고

Improper installation, adjustment, alteration, service, or maintenance can cause property damage, personal injury, or loss of life. Installation and service must be performed by a licensed professional HVAC installer (or equivalent), a qualified service agency, or the gas supplier.

주의

As with any mechanical equipment, personal injury can result from contact with sharp sheet metal edges. Exercise caution when handling this equipment.

키트 구성 요소view

Lennox 83M00 LB-109531A Sure Light Replacement Kit components

Figure 1: The image displays the complete Lennox 83M00 LB-109531A Sure Light Replacement Kit. Visible components include the instruction manual with wiring diagrams, a metal mounting plate, a wiring harness with various connectors, and the main SureLight ignition control circuit board (4544-G).

설치 지침

올바른 설치를 위해 다음 단계를 주의 깊게 따르세요.

  1. Disconnect electrical power and shut off the gas supply to the furnace before beginning any work.
  2. Remove the furnace access panel to gain access to the control area.
  3. Carefully label and disconnect all wiring from the existing ignition control. Then, remove the existing ignition control from its mounting in the control box.
  4. Install the provided circuit breaker in the unit control box or secure the circuit breaker to a wire harness using wire ties.
  5. Position the provided mounting panel so that the black arrow on the front of the panel is pointing upwards. Align the replacement SureLight ignition control over the holes marked "A" in Figure 1 (refer to the manual's diagram). Insert the replacement control stand-off fasteners (which are already integrated into the control) into the corresponding holes in the mounting panel. Snap the replacement SureLight® ignition control securely onto the mounting panel.
  6. Insert the four provided stand-off fasteners into the back of the mounting panel, aligning them with the holes marked "B" in Figure 1. Snap the mounting panel (including the newly installed control) into the control box.

작업

Once properly installed by a qualified professional, the Lennox Sure Light Replacement Kit operates automatically to control the ignition sequence of your gas furnace. The control board manages the flow of electricity and gas to ensure safe and efficient furnace startup and operation. No direct user interaction is typically required for its operation.

유지

The Lennox 83M00 LB-109531A Sure Light Replacement Kit is designed for reliable, long-term operation with minimal maintenance. Regular maintenance of the overall furnace system by a qualified HVAC technician is recommended to ensure all components, including the ignition control, are functioning correctly. This typically involves annual inspections and cleaning of the furnace.

문제 해결

If the furnace experiences ignition issues after the installation of this kit, consult a qualified HVAC technician. Common issues related to ignition controls often require specialized diagnostic tools and knowledge. Ensure all wiring connections are secure and that the furnace is receiving proper power and gas supply. Refer to the furnace's main instruction manual for specific troubleshooting steps related to the overall heating system.

명세서

  • 상표: 레녹스
  • 모델: 83M00 LB-109531A
  • 단위 수: 1.0 카운트
  • 항목 수: 1
  • 품목 패키지 수량: 1
  • 품목 무게: 0.01 온스
  • ASIN: B00Y1PIQ56
  • 첫 이용 가능 날짜: 21년 2015월 XNUMX일
  • Automatic Ignition System: 24VAC 60Hz, 0.5A MAX (as per circuit board label)

보증 정보

For specific warranty details regarding the Lennox 83M00 LB-109531A Sure Light Replacement Kit, please refer to the documentation provided with your original furnace or contact Lennox customer support directly. Warranty terms typically cover manufacturing defects under normal use conditions.

고객 지원

If you require technical assistance, have questions about installation, or need to report an issue, please contact Lennox customer support or your authorized Lennox dealer. Ensure you have your product model number (83M00 LB-109531A) and any relevant purchase information available when contacting support.

관련 문서 - 83M00 LB-109531A

사전view 레녹스 ML193UHE(K) 가스 난방기 제품 사양
Lennox ML193UHE(K) 주거용 가스 난방기의 상세 제품 사양, 기능, 설치 지침 및 선택 사양 액세서리에 대한 정보입니다. 이 문서에는 기술 세부 정보, 성능 데이터 및 모델 식별 정보가 포함되어 있습니다.
사전view Lennox SLP99DFVK 가스 퍼니스 설치 지침
Lennox SLP99DFVK Dave Lennox Signature Collection 가스 퍼니스에 대한 종합적인 설치 안내서입니다. 전문 HVAC 설치 기사를 위한 안전, 설치, 전기, 가스 배관, 환기 및 문제 해결 방법을 다룹니다.
사전view Lennox SureLight 점화 제어 장치 교체 키트 설치 가이드
가스 난방기의 Lennox SureLight 점화 제어 보드를 교체하기 위한 자세한 설치 지침 및 배선도입니다. 안전 주의사항, 부품 목록, 부품 참조표 및 진단 코드가 포함되어 있습니다.
사전view Lennox 통합 제어 교체 키트 23C48 설치 지침
Lennox 통합 제어 교체 키트 23C48 설치 가이드로, 단일 스위치 구성에 대한 단계별 지침과 배선도를 제공합니다.tag일정한 토크의 실내 송풍기 모터를 갖춘 난방기.
사전view 레녹스 EL280UH(X)EK 엘리트 시리즈 가스 난방기 설치 설명서
레녹스 EL280UH(X)EK 엘리트 시리즈 가스 난방기의 종합적인 설치 지침입니다. 이 안내서는 제품 크기, 안전 수칙, 상향식 및 수평식 설치, 배기, 가스 배관, 전기 및 시동 절차를 다룹니다.
사전view 레녹스 EL280DFE 가스 난방기 설치 설명서
레녹스 EL280DFE 엘리트 시리즈 가스 난방기의 안전, 간격, 덕트, 환기, 가스 배관, 전기 연결, 장치 설정, 작동 및 유지 보수에 대한 포괄적인 설치 가이드입니다.