1. 서론
This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Astralpool Digital Display Anti-Freeze Control Box, model FD-45600. Please read this manual thoroughly before installation and use to ensure proper function and longevity of the product.
The Astralpool Anti-Freeze Control Box is designed to protect your swimming pool's hydraulic installation from freezing temperatures by automatically activating the filtration pump when the water temperature drops below a set threshold.
2. 안전 정보
중요 안전 지침:
- Installation must be performed by a qualified professional electrician in accordance with local electrical codes and regulations.
- 설치, 유지보수 또는 수리 작업을 수행하기 전에 반드시 전원 공급 장치를 차단하십시오.
- The control box is rated IP54, providing protection against dust and splashing water. However, it should not be submerged or exposed to direct high-pressure water jets.
- 부품이 손상된 경우 장치를 작동하지 마십시오.
- Keep children away from the control box and pool equipment.
3. 제품 특징
The Astralpool Digital Display Anti-Freeze Control Box offers the following key features:
- IP54 Enclosure: 먼지와 물 튀김으로부터 보호해 줍니다.
- NTC 프로브: High-precision temperature sensor for accurate readings.
- 디지털 디스플레이: Clear digital readout for temperature and settings.
- 보편적 인 호환성 : Adaptable to existing pool installations.
- Complete Anti-Freeze Kit: Simplifies pool winterization and spring opening.
- Automatic Filtration Activation: Protects against freezing by circulating pool water.
4. 패키지 내용
포장을 풀 때 모든 구성 요소가 들어 있고 손상되지 않았는지 확인하세요.
- Astralpool Digital Display Anti-Freeze Control Box (FD-45600)
- NTC 온도 프로브
- 사용 설명서(본 문서)

그림 1: Astralpool Digital Display Anti-Freeze Control Box (FD-45600) with its NTC temperature probe. The control box features a digital display and control buttons, while the probe is connected via a cable.
5. 설정 및 설치
전문 설치 필요: This electrical control box must be installed by a qualified professional to ensure safety and compliance with electrical standards.
5.1 제어 상자 장착
- Choose a suitable location for the control box, protected from direct sunlight and excessive moisture, yet accessible for operation and maintenance.
- Ensure the mounting surface is stable and capable of supporting the weight of the unit.
- Mount the control box securely using appropriate fasteners.
5.2 전기 연결
All electrical connections must be made with the main power supply disconnected.
- Connect the main power supply to the designated terminals within the control box.
- Connect the pool filtration pump to the output terminals of the control box.
- Connect the NTC temperature probe to its dedicated input terminals.
- 모든 연결부가 단단히 고정되고 적절하게 절연되었는지 확인하십시오.
5.3 NTC Probe Placement
The NTC probe measures the water temperature. Its correct placement is crucial for accurate readings and effective anti-freeze protection.
- Install the NTC probe in the pool's hydraulic circuit, ideally after the filter and before any heating elements, in a location that accurately reflects the pool water temperature.
- Ensure the probe is fully immersed in the water flow.
6. 운영
6.1 전원 켜기
Once installation is complete and verified by a professional, restore power to the control box. The digital display will illuminate, showing the current water temperature.
6.2 Setting the Anti-Freeze Threshold
The anti-freeze threshold is the temperature at which the control box will activate the filtration pump to prevent freezing.
- Press and hold the "SET" button for more than 2 seconds.
- The display will show the current set point temperature (e.g., "C" followed by the temperature in °C).
- Use the "Up" (▲) and "Down" (▼) buttons to adjust the desired anti-freeze temperature. A common setting is between 1°C and 4°C.
- To confirm and save the new set point, press the "SET" button again, or wait for 10 seconds for the setting to automatically save and return to normal operation.
6.3 자동 작동
When the water temperature measured by the NTC probe falls below the set anti-freeze threshold, the control box will automatically activate the pool filtration pump. The pump will run until the water temperature rises above the threshold, preventing ice formation in the pipes and equipment.
This system simplifies active winterization, allowing the pool to remain filled without the need to significantly lower the water level.
7. 유지관리
Regular maintenance ensures the reliable operation and longevity of your anti-freeze control box.
- 연례 검사: Have a qualified professional inspect the control box and all electrical connections annually, especially before the winter season.
- 청결: Keep the exterior of the control box clean and free from dust and debris. Use a soft, dry cloth for cleaning. Do not use abrasive cleaners or solvents.
- 프로브 점검: Periodically check the NTC temperature probe for any signs of damage or corrosion. Ensure it is securely in place and fully immersed in water.
- 기능성 테스트: Before winter, test the anti-freeze function by temporarily lowering the set point or using a cold object near the probe (if safely accessible) to verify the pump activates.
8. 문제 해결
이 섹션에서는 일반적인 문제에 대한 해결책을 제공합니다. 여기에 나열되지 않은 문제가 발생하거나 문제가 지속될 경우, 자격을 갖춘 서비스 기술자에게 문의하십시오.
| 문제 | 가능한 원인 | 해결책 |
|---|---|---|
| 화면이 꺼져 있음 / 전원이 없음 | 전원 공급 안 됨; 퓨즈 단선됨; 연결 불량 | Check main power supply; Inspect fuses; Verify electrical connections (by a professional). |
| Pump does not activate when temperature is low | Incorrect set point; Faulty NTC probe; Pump issue; Wiring error | Verify anti-freeze set point; Check NTC probe connection/function; Inspect pump operation; Have wiring checked by a professional. |
| 부정확한 온도 측정 | NTC probe improperly placed; Faulty NTC probe | Ensure probe is fully immersed and in proper location; Replace NTC probe if faulty. |
| 펌프가 지속적으로 작동 | Set point too high; Faulty NTC probe; Control box malfunction | Adjust set point to a lower, appropriate temperature; Check NTC probe; Contact service technician. |
9. 사양
- 모델: FD-45600
- 상표: 아스트랄풀
- 인클로저 보호: IP54
- 온도 센서: NTC 프로브
- 표시하다: 디지털
- 호환성: Adaptable to existing installations
- 제조업체: 아스트랄 풀
10. 보증 및 지원
이 제품에는 다음이 포함되어 있습니다. 1년 보증 from the date of purchase, covering manufacturing defects. The warranty does not cover damage resulting from improper installation, misuse, neglect, or unauthorized repairs.
For technical support, warranty claims, or spare parts inquiries, please contact your authorized Astralpool dealer or the manufacturer directly. Please have your model number (FD-45600) and proof of purchase available when contacting support.
현재 예비 부품 재고 정보는 제공되지 않습니다.