1. 서론
The QuietWarmth THERMST-D Non-Programmable Thermostat is designed to provide reliable control for 120V or 240V electric radiant floor heating systems. This thermostat offers flexible temperature management, allowing you to configure it for control based on floor temperature, room temperature, or a combination of room temperature with a floor temperature limit. It features a built-in Ground Fault Circuit Interrupter (GFCI) for enhanced safety and a clear, backlit display for easy monitoring and operation. A floor sensor is included to ensure accurate temperature readings and optimal comfort.

그림 1: 전면 view of the THERMST-D Thermostat.
2. 안전 정보
Please read all instructions carefully before installation and operation. Failure to follow these instructions may result in electric shock, fire, or property damage.
- 경고: To reduce the risk of electric shock, do not connect this device to a circuit with any phase operating down more than 150 volts to ground.
- 설치는 해당 지역 및 국가 전기 규정에 따라 자격을 갖춘 전기 기술자가 수행해야 합니다.
- The thermostat requires connection to a dedicated 20 Amp 회로.
- The resistive load connected to the thermostat must not exceed 15 Amps.
- Electric radiant floor heating systems are required by the National Electrical Code to be protected by a Ground Fault Circuit Interrupter (GFCI). This thermostat has a built-in GFCI.
- 온도 조절기를 설치하거나 수리하기 전에 항상 회로 차단기에서 전원을 차단하십시오.

그림 2: 측면 view of the thermostat with safety warning label.
3. 패키지 내용
패키지에 모든 품목이 들어 있는지 확인하세요.
- QuietWarmth THERMST-D Non-Programmable Thermostat
- 플로어 센서
4. 제품 오버view
4.1 주요 특징
- Non-Programmable operation for radiant floor heat systems.
- Compatible with both 120V and 240V heating systems.
- Integrated Ground Fault Circuit Interrupter (GFCI) for safety.
- Clear, backlit LED display for easy reading.
- Includes a floor sensor for precise temperature control.
- Configurable for floor temperature, room temperature, or room temperature with a floor temperature limit.
- Seven-day energy log to monitor power consumption.
- Supports multiple QuietWarmth mats: up to 120 sq ft for 120V systems, or 240 sq ft for 240V systems.
4.2개의 구성요소
The thermostat consists of a front display unit with control buttons and a back plate for electrical connections.
- 전면 패널: Features a digital display showing time and temperature, along with 'Up', 'OK', and 'Down' buttons for navigation and setting adjustments.
- 후면 패널 : Contains wiring terminals for power input (L1, L2) and load output, as well as a connection point for the floor sensor.

그림 3: 뒤로 view of the thermostat with wiring terminals.

Figure 4: Included floor sensor.
5. 설정 및 설치
설치는 자격을 갖춘 전기 기술자만 수행해야 합니다.
5.1 장착
- The thermostat is designed for wall mounting.
- Ensure the mounting location is free from direct sunlight, drafts, or other heat sources that could affect temperature readings.
5.2 배선
Before wiring, ensure power is OFF at the circuit breaker.
- Connect the thermostat to a dedicated 20 Amp 회로.
- Identify the Line (power supply) and Load (heating mat) wires.
- Connect the Line wires to the L1(L) and L2(N) terminals on the thermostat's back panel.
- Connect the Load wires from the heating mat to the 'Load' terminals on the thermostat.
- 현지 전기 규정에 따라 적절한 접지를 확보하십시오.
- The thermostat is dual-voltage; it can be used with either 120V or 240V heating mats, but not simultaneously. Verify your heating mat's voltage는 전원 공급 장치와 일치합니다.
5.3 Floor Sensor Placement
The floor sensor is crucial for accurate floor temperature control.
- Place the sensor next to the long edge of the QuietWarmth heating mat.
- Ensure the sensor is positioned in the heated area and not near any unheated zones or external heat sources.
- Route the sensor wire carefully to avoid damage during installation of flooring materials.

그림 5: 예ample of radiant heat film installation under floating floors.

그림 6: 예ample of radiant heat film installation under tile and glued floors.
6. 사용 설명서
6.1 전원 켜기
After installation, restore power at the circuit breaker. The thermostat display will illuminate.
6.2 온도 설정
- 사용하세요 Up 그리고 아래에 버튼을 눌러 원하는 온도를 조절하세요.
- 를 누르세요 OK 선택을 확인하려면 버튼을 클릭하세요.
6.3 제어 모드
The thermostat can be configured to operate in one of three control modes:
- Floor Temperature Control: The thermostat maintains the floor at the set temperature using the floor sensor.
- 실내 온도 조절: The thermostat maintains the room air temperature at the set point.
- Room Temperature Control with Floor Limit: The thermostat primarily controls room air temperature but prevents the floor temperature from exceeding a specified maximum limit, protecting sensitive flooring materials.
Refer to the full installation guide for instructions on how to select and configure these control modes.
6.4 Energy Log
The thermostat features a seven-day energy log, allowing you to monitor the power consumption of your radiant heating system. Consult the detailed manual for accessing and interpreting this data.
7. 유지관리
7.1 GFCI Testing
For continued safety, the built-in GFCI should be tested monthly.
- 를 누르세요 시험 button located on the bottom of the thermostat.
- The GFCI should trip, cutting power to the heating system and indicating a fault.
- 를 누르세요 다시 놓기 button to restore power.
- If the GFCI does not trip or reset correctly, discontinue use and contact a qualified electrician.

Figure 7: Bottom of the thermostat with GFCI test button.
7.2 청소
온도 조절 장치 외부를 부드러운 천으로 닦으세요.amp 천. 연마성 세척제나 용매를 사용하지 마십시오.
8. 문제 해결
If you encounter issues with your QuietWarmth THERMST-D thermostat, refer to the following common problems and solutions:
- 디스플레이 없음/전원 없음:
- Check the circuit breaker for the dedicated circuit and ensure it is in the ON position.
- 모든 배선 연결이 안전하고 올바른지 확인하세요.
- 난방 시스템이 작동하지 않음:
- Ensure the thermostat is set to a temperature higher than the current room or floor temperature.
- Check if the GFCI has tripped (press the RESET button if it has).
- Confirm the correct control mode is selected (floor, room, or room with limit).
- GFCI Trips Frequently:
- This indicates a ground fault. Immediately turn off power at the circuit breaker.
- Inspect the heating mat and wiring for any damage or moisture.
- Ensure the total resistive load does not exceed 15 Amps.
- 진단 및 수리를 위해 자격을 갖춘 전기 기술자에게 문의하십시오.
- 부정확한 온도 측정값:
- Verify the floor sensor is correctly installed and not damaged.
- Ensure the thermostat is not exposed to drafts, direct sunlight, or other external heat sources.
For issues not covered here, please contact QuietWarmth customer support or a qualified electrician.
9. 사양
| 사양 | 세부 사항 |
|---|---|
| 상표 | 조용한따뜻함 |
| 모델명 | QuietWarmth Non-Programmable Thermostat |
| 부품 번호 | 테르미스트-D |
| 제품 치수 | 3인치 깊이 x 4인치 너비 x 6인치 높이 |
| 품목 무게 | 11.4 온스 |
| 색상 | 하얀색 |
| 재료 | 플라스틱 |
| 권tage | 120볼트, 240볼트 |
| Max Resistive Load | 15 Amps |
| 전원 | 하드와이어드 |
| 컨트롤러 유형 | 푸시 버튼 |
| 온도 제어 유형 | 수동 |
| 디스플레이 유형 | LED (백라이트) |
| 연결 기술 | 열광한 |
| 특징 | Energy Usage Tracking, Built-in GFCI |
| 장착 유형 | 벽걸이형 |
| 사양 충족 | UL |
| 한국어: | 696087109103 |
10. 보증 및 지원
10.1 보증 정보
The QuietWarmth THERMST-D Non-Programmable Thermostat comes with a 3-year limited warranty from the date of purchase. This warranty covers defects in materials and workmanship under normal use. Please retain your proof of purchase for warranty claims.
10.2 고객 지원
For technical assistance, troubleshooting, or warranty inquiries, please contact QuietWarmth customer support. Refer to the product packaging or the manufacturer's web최신 연락처 정보는 사이트에서 확인하세요.