1. 서론
This manual provides essential information for the proper installation, operation, and maintenance of your Hunter Sprinkler ICM600 I-Core 6-Station Plug-in Expansion Module. The ICM600 is designed to expand the zone capacity of compatible Hunter I-Core irrigation controllers, allowing for the addition of up to six (6) conventional irrigation zones. Please read these instructions thoroughly before proceeding with installation or use to ensure optimal performance and safety.
2. 안전 정보
경고: To reduce the risk of electrical shock or injury, always observe the following safety precautions:
- 이 제품을 어린이의 손이 닿지 않는 곳에 보관하세요.
- Avoid direct contact with skin and eyes during handling and installation.
- Always disconnect power to the irrigation controller before installing or removing the expansion module.
- 전기적 위험을 방지하기 위해 모든 배선 연결이 안전하고 적절하게 절연되어 있는지 확인하세요.
- 모듈이 손상된 것으로 보이면 작동하지 마세요.
3. 제품 오버view
The Hunter ICM600 is a plug-in expansion module specifically designed for the Hunter I-Core series of irrigation controllers. It provides an additional six (6) conventional station outputs, allowing you to manage more irrigation zones from a single I-Core controller. This module facilitates easy system expansion without requiring a complete controller replacement.

그림 1: Hunter ICM600 I-Core 6-Station Plug-in Expansion Module. This image shows the compact design of the module, which plugs directly into the I-Core controller to add six additional irrigation zones.
4. 설정 및 설치
- 전원 끄기 컨트롤러: Before beginning, ensure the main power to your Hunter I-Core controller is completely disconnected. This prevents electrical shock and damage to the module or controller.
- Locate Module Slots: Open the controller's front panel. Identify the available expansion module slots within the controller. These are typically labeled.
- 모듈 삽입: Carefully align the ICM600 module with an empty slot. The module is designed to fit in only one orientation. Gently push the module firmly into the slot until it is fully seated. Do not force the module.
- 구역 배선을 연결하세요: Once the module is securely in place, connect the irrigation zone wires to the corresponding terminals on the ICM600 module. Ensure each wire is stripped appropriately and securely fastened under its terminal screw. Refer to your I-Core controller's main manual for specific wiring diagrams if needed.
- 복원력 : Close the controller's front panel and restore power to the I-Core controller. The controller should automatically detect the newly installed module.
5. 운영
After successful installation, your Hunter I-Core controller will automatically recognize the ICM600 expansion module and the additional six zones it provides. You can then program these new zones using the standard programming interface of your I-Core controller.
- 구역 할당: The controller will assign sequential zone numbers to the new stations provided by the module.
- 프로그램 작성: Access the programming menu on your I-Core controller to set start times, run times, and watering days for the newly available zones, just as you would for the controller's built-in zones.
- 테스트: After programming, perform a manual test of each new zone to ensure proper operation of the connected valves.
6. 유지관리
The ICM600 module requires minimal maintenance. Regular checks can help ensure its longevity and reliable performance:
- 시각적 검사: Periodically inspect the module and its connections for any signs of corrosion, loose wires, or physical damage.
- 청결: Keep the controller enclosure clean and free from dust, dirt, and insects, which can interfere with electronic components.
- 환경 보호: Ensure the controller and module are protected from extreme weather conditions, direct sunlight, and moisture, as specified in the I-Core controller's manual.
7. 문제 해결
If you encounter issues with your ICM600 expansion module, consider the following troubleshooting steps:
| 문제 | 가능한 원인 | 해결책 |
|---|---|---|
| Module not detected by controller | Module not fully seated; power not cycled; faulty module. | Disconnect power, re-seat the module firmly, then restore power. If issue persists, contact Hunter support. |
| New zones not activating | Incorrect wiring; zone not programmed; faulty solenoid; module issue. | Verify zone wiring connections. Check controller programming for the new zones. Test the solenoid at the valve. If the module has an indicator light for the zone, a 빨간불 typically indicates a wiring fault or short circuit on that zone. |
| Controller displays error related to module | Module malfunction; communication error. | Power cycle the controller. If the error persists, try moving the module to a different slot (if available) or contact Hunter technical support. |
8. 사양
- 상표: 사냥꾼
- 모델: ICM600
- 스테이션 수: 6 (conventional)
- 호환성: Hunter I-Core Controllers
- 재료: 플라스틱
- 색상: 회색
- 제품 크기(길이 x 너비 x 높이): 5 x 7 x 10 인치
- 품목 무게: 2.4 온스
- 최대 압력: 40 Pound per Square Inch (relevant for connected system, not module itself)
- 제조업체: Standard Plumbing Supply-LG
- 한국어: 611698157329
9. 보증 및 지원
For detailed warranty information, technical support, or service inquiries regarding your Hunter ICM600 I-Core 6-Station Plug-in Expansion Module, please refer to the official Hunter Industries web사이트를 방문하거나 고객 서비스에 직접 문의하세요. 보증 청구를 위해 구매 영수증을 보관하세요.