1. 서론
This manual provides essential information for the proper installation, operation, and maintenance of the Lennox OEM Replacement Furnace Control Board, model 103085-02. This control board is designed to replace original equipment manufacturer (OEM) parts in compatible Lennox furnace systems. Please read this manual thoroughly before attempting any installation or service.
2. 안전 정보
경고: 감전 위험. 정비 전에 전원을 차단하십시오.
- Installation and servicing of heating, ventilation, and air conditioning (HVAC) equipment can be hazardous due to electrical components and sharp edges. Only qualified service personnel should install, repair, or service HVAC equipment.
- Always disconnect the main electrical power to the furnace before installing or servicing the control board to prevent electrical shock.
- 모든 배선 연결이 안전하고 지역 및 국가 전기 규정을 준수하는지 확인하세요.
- 설치 작업 중에는 안전 고글과 장갑과 같은 적절한 개인 보호 장비(PPE)를 착용하십시오.
- 교체용 보드를 설치하기 전에 해당 보드가 사용 중인 난방기 모델과 호환되는지 확인하십시오.
3. 제품 오버view
The Lennox OEM Replacement Furnace Control Board 103085-02 is a critical component responsible for managing the operational sequences of your furnace. It controls various functions including ignition, fan operation, and safety limits, ensuring efficient and safe heating. This board is a direct replacement for the original part, designed to restore full functionality to your HVAC system.

그림 1: Lennox OEM Replacement Furnace Control Board 103085-02. This image displays the circuit board with various electronic components, relays, and terminal blocks for wiring connections. Key features include multiple relays for controlling different furnace functions, a fuse for circuit protection, and clearly labeled terminal blocks for power, thermostat, and component connections.
4. 설정 및 설치
Installation of this furnace control board should only be performed by a qualified HVAC technician. Incorrect installation can lead to property damage, serious injury, or death. The following steps are general guidelines; always refer to your specific furnace model's service manual for detailed instructions.
- 전원 차단: 메인 배전반에서 난방기의 모든 전원을 차단하십시오. 전압계를 사용하여 전원이 차단되었는지 확인하십시오.tag전자 미터.
- 접근 제어 보드: 보일러 접근 패널을 찾아 열어 기존 제어 보드를 드러내십시오.
- 문서 배선: Before disconnecting any wires, take clear photographs of all wiring connections to the existing board. Label each wire and its corresponding terminal for accurate re-connection.
- 전선 분리: 오래된 제어판에서 모든 전선을 조심스럽게 분리합니다.
- 오래된 보드 제거: 기존 제어 보드를 하우징에서 분리합니다. 보드의 방향을 기억해 두세요.
- 새 보드 설치: Mount the new Lennox 103085-02 control board in the same position as the old one.
- 배선을 다시 연결하세요: Using your photographs and labels, carefully reconnect all wires to their correct terminals on the new board. Ensure all connections are secure. Refer to 그림 1 for a visual reference of the board's layout.
- 퓨즈 교체: If applicable, ensure the correct fuse (e.g., 3 amp 또는 5 amp, as specified by your furnace manufacturer) is installed in the fuse holder on the new board.
- 보안 패널: 보일러 점검 패널을 닫고 단단히 고정하십시오.
- 복원력 : 메인 배전반에서 난방 장치의 전원을 복구하십시오.
- 테스트 작업: Initiate a heating cycle to verify proper furnace operation. Observe for any error codes or unusual behavior.
5. 작동 원리
The control board itself does not have user-operable controls. Its function is to interpret signals from the thermostat and safety devices, then execute the necessary actions to operate the furnace. This includes:
- 점화 순서: Initiating the igniter and opening the gas valve when a call for heat is received.
- 화염 감지: Monitoring the flame presence to ensure safe combustion.
- Blower Fan Control: Activating the indoor blower fan at appropriate times during heating and cooling cycles.
- Safety Limit Monitoring: Shutting down the furnace if safety limits (e.g., high temperature, pressure switch) are exceeded.
- 진단 코드: Providing diagnostic fault codes via an LED indicator to assist in troubleshooting.
Normal operation of the furnace is controlled by your thermostat settings. Ensure your thermostat is set to the desired mode (Heat, Cool, Auto) and temperature.
6. 유지관리
The Lennox 103085-02 control board is designed for reliable, long-term operation and typically requires minimal direct maintenance. However, regular maintenance of the overall furnace system is crucial for the longevity of all components, including the control board.
- 연간 난방기 점검: Have your furnace inspected annually by a qualified HVAC technician. They can check for proper operation, clean components, and identify potential issues before they lead to control board failure.
- 주변을 깨끗하게 유지하세요: Ensure the area around the furnace is clean and free of dust and debris, which can accumulate on electronic components and affect performance.
- 배선 검사: During annual inspections, ensure all wiring connections to the control board are tight and free from corrosion or damage.
- 퓨즈 확인: Periodically inspect the fuse on the control board for signs of damage or being blown. Always replace with a fuse of the correct amp분노 등급.
7. 문제 해결
Many furnace control boards include an LED indicator that flashes diagnostic codes to help identify issues. Consult your furnace's specific service manual for a list of these codes and their meanings. Common symptoms that may indicate a control board issue include:
- Furnace not starting or failing to ignite.
- Blower fan running continuously or not turning on.
- Intermittent furnace operation.
- No power to the thermostat or other furnace components.
- Repeated blowing of the control board fuse.
If you experience any of these issues, it is recommended to contact a qualified HVAC technician for diagnosis and repair. Attempting complex repairs without proper training can be dangerous.
8. 사양
| 상표 | 레녹스 |
| 모델 번호 | 103085-02 (OEM Replacement) |
| 품목 모델 번호(제조업체) | 세코미노드048127 |
| 품목 무게 | 10 온스 |
| 제품 치수 | 6 x 6 x 6 인치 |
| 제조업체 | 레녹스 |
| 부품 번호 | 세코미노드048127 |
| ASIN | B00FQHQKLU |
9. 보증 정보
Specific warranty details for the Lennox OEM Replacement Furnace Control Board 103085-02 are typically provided by the seller or manufacturer at the time of purchase. Please retain your proof of purchase for any warranty claims. For detailed warranty terms and conditions, contact the authorized Lennox dealer or the point of purchase.
10. 고객 지원
For technical assistance, installation questions, or troubleshooting beyond the scope of this manual, please contact a qualified HVAC professional or an authorized Lennox service provider. You may also refer to the official Lennox website for additional resources or to locate a service technician in your area.