tekmar 152

테크마 투 Stage 설정값 제어 152 사용자 설명서

모델: 152

소개

This manual provides comprehensive instructions for the installation, operation, and maintenance of the Tekmar Two Stage Setpoint Control 152. This microprocessor-based control is designed to function either as a two-stage setpoint control or as two independent setpoint controls. It supports two-stage 가열, 2-stage cooling, or a combined heating/cooling interlock function. When configured for independent operation, it can manage any combination of heating or cooling devices. Please read this manual thoroughly before installation and operation to ensure proper use and optimal performance.

안전 정보

경고: 부적절한 설치, 조정, 변경, 서비스 또는 유지보수는 재산 피해, 부상 또는 사망을 초래할 수 있습니다. 이 장비를 설치하거나 서비스하기 전에 설치 및 작동 지침을 철저히 읽으십시오.

제품 끝view

The Tekmar 152 control features a digital display and intuitive buttons for setting parameters. It is designed for precise temperature management in HVAC systems.

테크마 투 Stage Setpoint Control 152 front view

그림 1: 앞쪽 view of the Tekmar Two Stage Setpoint Control 152. This image shows the white rectangular control unit with a grey central panel. The panel includes a digital display at the top, three buttons below it labeled "Setpoint", "Differential", and "Delay", and two arrow buttons (up and down) for navigation. The Tekmar logo and model number "Two Stage Setpoint Control 152" are also visible.

주요 특징:

설정 및 설치

Before beginning installation, ensure all power to the HVAC system is disconnected at the main breaker.

설치:

  1. Select a suitable location for the control, away from direct sunlight, drafts, and heat sources.
  2. Mount the control securely to a wall or electrical box using appropriate fasteners.

배선:

Refer to the wiring diagram provided with the product packaging for specific connections. General steps include:

  1. Connect the power supply wires to the designated terminals on the control.
  2. Connect the sensor wires to the sensor input terminals.
  3. Connect the output wires for heating/cooling stages to the appropriate terminals, ensuring correct polarity.
  4. 전원을 다시 공급하기 전에 모든 연결부가 단단히 고정되었는지, 배선이 올바른지 다시 한번 확인하십시오.

Note: Professional installation is recommended to ensure compliance with all electrical codes and optimal system performance.

작동 지침

The Tekmar 152 control is operated using the three main buttons and the up/down arrow buttons on the front panel.

Setting the Setpoint:

  1. Press the "Setpoint" button. The current setpoint value will flash on the digital display.
  2. Use the "Up" or "Down" arrow buttons to adjust the setpoint to the desired temperature or value.
  3. Press the "Setpoint" button again to confirm and save the new setting, or wait a few seconds for it to save automatically.

Adjusting Differential:

The differential setting determines the temperature band around the setpoint before the control activates or deactivates a stage.

  1. Press the "Differential" button. The current differential value will flash.
  2. Use the "Up" or "Down" arrow buttons to adjust the differential.
  3. Press the "Differential" button again to confirm.

Configuring Delay:

The delay setting prevents rapid cycling of equipment, extending its lifespan.

  1. Press the "Delay" button. The current delay value will flash.
  2. Use the "Up" or "Down" arrow buttons to adjust the delay time.
  3. Press the "Delay" button again to confirm.

투에스tage vs. Independent Control:

The operating mode (two-stage or independent) is typically configured during initial setup by a qualified technician. Consult your installer or the full technical manual for details on changing this mode.

유지

The Tekmar 152 control requires minimal maintenance.

Note: For any internal maintenance or repairs, contact a qualified service technician.

문제 해결

문제가능한 원인해결책
Control display is blank전원 공급이 없습니다Check circuit breaker and wiring connections to the control.
System not responding to setpointIncorrect setpoint/differential; Sensor fault; Wiring issueVerify setpoint and differential settings. Check sensor wiring and sensor operation. Inspect output wiring.
Equipment cycles too frequentlyDifferential too small; Delay setting too shortIncrease the differential setting. Increase the delay time.
부정확한 온도 판독값Faulty sensor; Sensor placement issueCheck sensor for damage. Relocate sensor if it's in a draft or near a heat source.

If the problem persists after attempting these solutions, contact a qualified HVAC technician or Tekmar customer support.

명세서

보증 및 지원

For warranty information, please refer to the documentation included with your product or visit the official Tekmar web대지.

For technical support or service inquiries, please contact Tekmar customer service. Contact details can typically be found on the manufacturer's web사이트 또는 제품 포장.

Visit the official Tekmar Store on Amazon

관련 문서 - 152

사전view tekmar 152 Two Stage Setpoint Control: Applications, Specifications, and Wiring Diagrams
Comprehensive guide to the tekmar 152 Two Stage Setpoint Control. Explore its use in Domestic Hot Water (DHW), Pool/Spa, and Fan Coil/Slab heating systems. Includes detailed operation, specifications, settings, and electrical wiring diagrams.
사전view tekmar Wi-Fi Setpoint Control 170: Installation, Operation, and Maintenance Manual
Comprehensive guide for installing, operating, and maintaining the tekmar Wi-Fi Setpoint Control 170. Covers features, setup, applications, troubleshooting, and technical specifications for smart home climate control.
사전view Tekmar Invita 564 HVAC Interface Module and Thermostat Installation Guide
Detailed guide for installing and configuring the Tekmar Invita 564 HVAC Interface Module, WiFi Thermostat, and Outdoor Sensor with a Bosch IDS Single-Stage Furnace. Includes wiring diagrams and setup menu options.
사전view tekmar Programmable Thermostat 510 & 511 Data Brochure
Explore the tekmar Programmable Thermostat 510 and 511 with this comprehensive data brochure. Learn about features, installation, operation, sensor compatibility, and technical specifications for efficient climate control.
사전view Troubleshooting Guide for tekmar 423 Universal Reset Module
Comprehensive troubleshooting guide for the tekmar 423 Universal Reset Module, covering sensor inputs, sensor checks, outdoor sensor notes, bypassing outdoor sensor, boiler firing issues, mixing control problems, floating action valve checks, variable speed pump operation, bus configuration, and DHW settings. Includes a detailed sensor resistance table.
사전view tekmar 30XP 시리즈 문제 해결 가이드
tekmar 30XP, 301P, 302P, 303P, 304P, 306P 존 펌프 컨트롤러에 대한 종합적인 문제 해결 가이드입니다. 존 펌프가 켜지지 않음, 호출 감지 안 됨, 온도 조절기 문제, 퓨즈 단선 등 일반적인 문제를 다룹니다.