Owon 01SDS6062

OWON SDS6062 60MHz 딥 메모리 디지털 저장 오실로스코프 사용 설명서

Model: 01SDS6062 | Brand: Owon

1. 서론

This manual provides comprehensive instructions for the safe and effective operation, maintenance, and troubleshooting of your OWON SDS6062 Digital Storage Oscilloscope. Please read this manual thoroughly before using the device to ensure proper functionality and to prevent damage.

The OWON SDS6062 is a 60 MHz Deep Memory Digital Storage Oscilloscope featuring 10 M points of memory and 2 channels. It is equipped with LAN and VGA interfaces for enhanced connectivity and display options. This package includes the oscilloscope, two probes, a power cable, a USB cable, this manual, and a CD with software.

2. 제품 오버view

2.1 주요 특징

2.2 상자 내용물

포장을 풀 때 아래 나열된 모든 품목이 들어 있고 상태가 양호한지 확인하세요.

2.3 제품 Views

앞쪽 view of the OWON SDS6062 Digital Storage Oscilloscope

그림 2.1: 전면 view of the OWON SDS6062 Digital Storage Oscilloscope, showing the large 8-inch display and control panel with various knobs and buttons for measurement, acquisition, horizontal, vertical, and trigger settings.

뒤쪽 view of the OWON SDS6062 Oscilloscope with power input

그림 2.2: 후면 view of the OWON SDS6062 Oscilloscope, highlighting the power input socket and the main power switch. The included power cable is also shown connected.

옆 view of the OWON SDS6062 Oscilloscope showing connectivity ports and probes

그림 2.3: 측면 view of the OWON SDS6062 Oscilloscope, illustrating the USB (Device and Host), VGA, LAN, and Probe Compensation ports. Two oscilloscope probes and a USB cable are also displayed, indicating the included accessories.

Dimensional representation of the OWON SDS6062 Oscilloscope

Figure 2.4: A silhouette showing the approximate dimensions of the OWON SDS6062 Oscilloscope, indicating a height of approximately 7.0 inches (17 cm) for scale.

3. 안전 정보

부상과 기기 손상을 방지하기 위해 항상 다음 안전 예방 조치를 준수하세요.

4. 설정

4.1 풀기 및 검사

Carefully remove the oscilloscope and all accessories from the packaging. Inspect for any signs of damage during transit. If any damage is found, contact your dealer immediately.

4.2 전원 연결

  1. Ensure the oscilloscope's power switch (located on the rear panel, refer to Figure 2.2) is in the OFF position.
  2. Connect the provided power cord to the AC power input socket on the rear panel of the oscilloscope.
  3. 전원 코드의 다른 쪽 끝을 접지된 AC 전원 콘센트에 꽂습니다.

4.3 프로브 연결 및 보정

  1. Connect the BNC connector of a probe to one of the input channels (CH1 or CH2) on the front panel.
  2. Attach the probe ground clip to the ground terminal on the oscilloscope's front panel (typically near the probe compensation output).
  3. Connect the probe tip to the probe compensation output terminal (PROBE COMP) on the front panel (refer to Figure 2.3).
  4. Power on the oscilloscope.
  5. Adjust the probe compensation screw on the probe until a flat-top square wave is displayed on the screen. This ensures accurate measurements.

4.4 Connecting to External Devices (LAN/VGA/USB)

The SDS6062 offers multiple connectivity options:

5. 사용 설명서

5.1 전원 켜기/끄기

To power on the oscilloscope, press the power switch on the rear panel to the ON position. To power off, press the switch to the OFF position.

5.2 디스플레이 이해

The 8-inch TFT display provides a clear view of waveforms and measurement parameters. The screen is divided into a grid for easy amplitude and time measurement. Key information such as channel status, trigger settings, and measurement values are displayed around the waveform area.

5.3 기본 파형 획득

  1. 프로브 연결: Ensure your probe is correctly connected to a channel (CH1 or CH2) and compensated.
  2. 회로에 연결: 프로브 끝을 회로의 테스트 지점에 연결하고 접지 클립을 회로의 접지에 연결하십시오.
  3. 자동 크기 조절: 를 누르세요 자동차 button on the front panel. The oscilloscope will automatically adjust the vertical and horizontal settings to display a stable waveform. This is useful for quickly viewing an unknown signal.
  4. 수동 조정:
    • Vertical Position (VOLTS/DIV): Use the vertical position knob for the selected channel to move the waveform up or down. Use the VOLTS/DIV knob to adjust the vertical scale (voltage 부서당).
    • Horizontal Position (SEC/DIV): Use the horizontal position knob to move the waveform left or right. Use the SEC/DIV knob to adjust the horizontal scale (time per division).

5.4 트리거링

Triggering stabilizes repetitive waveforms and captures single-shot events. The trigger controls are located on the right side of the front panel.

5.5 측정

The SDS6062 offers various automatic measurement functions:

5.6 Pass/Fail Function

The Pass/Fail function allows for automated testing against predefined waveform masks. If a waveform falls outside the specified mask, it is flagged as a "Fail".

5.7 데이터 저장 및 불러오기

Waveforms, setups, and screenshots can be saved to internal memory or a USB flash drive.

6. 유지관리

6.1 일반 관리 및 청소

To maintain the performance and longevity of your oscilloscope:

6.2 보관

When not in use for extended periods, store the oscilloscope in a cool, dry environment, away from direct sunlight and extreme temperatures. Use the original packaging or a suitable carrying case to protect it from physical shock and dust.

7. 문제 해결

This section addresses common issues you might encounter with your OWON SDS6062 oscilloscope. If the problem persists after following these steps, contact customer support.

문제가능한 원인해결책
전원을 켠 후 표시되지 않습니다.Power cord not connected; power switch off; power outlet fault.Ensure power cord is securely connected. Verify power switch is ON. Test power outlet with another device.
파형이 표시되지 않습니다.Probe not connected; signal too small/large; incorrect vertical/horizontal settings; trigger issues.Verify probe connection to channel and circuit. Press 자동차. Adjust VOLTS/DIV and SEC/DIV. Check trigger level and mode.
불안정하거나 롤링하는 파형.트리거 설정이 잘못되었거나 신호에 노이즈가 있습니다.Adjust trigger level. Change trigger mode (e.g., to Edge). Select appropriate trigger source. Ensure stable signal input.
VGA/LAN/USB connectivity issues.Cable not connected; driver issues; software incompatibility; port malfunction.Ensure cables are securely connected. Install/reinstall drivers from the included CD. Verify software compatibility with your operating system. Test with different cables/ports if possible.
부정확한 측정.Probe not compensated; incorrect probe attenuation setting; signal distortion.Perform probe compensation (Section 4.3). Ensure probe attenuation setting on oscilloscope matches the probe (e.g., 1X, 10X). Check signal integrity.

8. 사양

매개변수
대역폭60MHz
채널2
Samp르 레이트500 MS/s (Real-time)
레코드 길이10백만 포인트
표시하다8-inch Color TFT LCD (800 x 600 pixels)
연결성LAN, VGA, USB (Host & Device)
기능Auto Scale, Pass/Fail, Multiple Measurement Types
치수(길이 x 너비 x 높이)14 x 3 x 7인치(대략)
무게5.5파운드(대략)
제조업체오원

9. 보증 및 지원

For information regarding warranty coverage, technical support, or service, please refer to the documentation included with your product or visit the official OWON web사이트. 보증 청구를 위해 구매 증빙 자료로 구매 영수증을 보관하세요.

제조업체: 오원

관련 문서 - 01SDS6062

사전view 마누엘의 오실로스코프 활용도 수치 OWON Série SDS
Manuel d'utilisation은 오실로스코프 숫자 OWON Série SDS, 전체 모델 SDS6062(V) à SDS9302, avec des Instructions d'opération, de sécurité et des specifications에 대해 설명합니다.
사전view OWON TAO3000 시리즈 휴대용 오실로스코프 사용자 설명서
OWON TAO3000 4채널 시리즈 휴대용 오실로스코프 사용 설명서로, 작동 방법, 특징, 기술 사양 및 문제 해결 방법을 자세히 설명합니다.
사전view OWON HDS200 시리즈 2채널 휴대용 오실로스코프 빠른 시작 가이드
이 빠른 시작 가이드는 OWON HDS200 시리즈 2채널 휴대용 오실로스코프(HDS272, HDS242, HDS2102, HDS2202 모델 포함)의 작동에 필요한 필수 정보를 제공합니다. 안전 수칙, 일반 점검, 오실로스코프 및 멀티미터 사용법, 신호 발생기 기능, 소프트웨어 연결, 문제 해결 및 유지 보수에 대한 내용을 다룹니다.
사전view 멀티미터 SCPI 프로토콜 가이드
OWON 멀티미터용 SCPI(Standard Commands for Programmable Instruments) 프로토콜을 살펴보세요. 이 가이드에서는 테스트 장비 프로그래밍을 위한 명령 구문, 규칙 및 일반 명령어를 자세히 설명합니다.
사전view OWON HDS200 시리즈 핸드헬드 오실로스코프 사용 설명서 - 작동 및 사양
이 종합 사용 설명서는 HDS272(S) 및 HDS242(S) 모델을 포함한 OWON HDS200 듀얼 채널 시리즈 핸드헬드 오실로스코프의 작동에 대한 자세한 지침을 제공합니다. 안전 정보, 일반 검사, 오실로스코프, 멀티미터, 그리고 옵션 파형 발생기 기능, 그리고 기술 사양 및 유지보수 지침에 대한 내용을 담고 있습니다.
사전view OWON FDS 듀얼 채널 시리즈 빠른 사용 설명서: 오실로스코프, 함수 발생기, 전원 공급 장치, 멀티미터
이 간편 안내서는 오실로스코프, 임의 파형/함수 발생기, 전원 공급 장치 및 멀티미터를 갖춘 다용도 기기인 OWON FDS 듀얼 채널 시리즈의 작동에 필요한 필수 정보를 제공합니다. Fujian LILLIPUT Optoelectronics Technology Co., Ltd.에서 제공하는 안전, 기본 기능 및 작동 팁을 확인해 보세요.