테크마르 078

Tekmar 078 범용 센서 (15피트 전선 포함) 사용 설명서

Model: 078 | Brand: Tekmar

소개

The Tekmar 078 Universal Sensor is designed for accurate temperature measurement in various applications. It features a robust, stiff jacketed cable for simplified installation into conduits or domestic hot water tank temperature wells. This versatile sensor can also be securely strapped to pipes to monitor supply or return temperatures.

주요 특징

  • 10K Thermistor: Provides precise temperature readings.
  • 높은 정확도: Achieves an accuracy of +/-0.2°C.
  • 내구성 있는 구조: Features a corrosion-resistant brass sleeve.
  • 빠른 응답: Offers very fast temperature response for dynamic monitoring.
  • 간편한 설치: Stiff jacketed cable facilitates straightforward wiring in conduit.
  • 인증: CSA and C US Approved for use in USA and Canada.

설정 및 설치

The Tekmar 078 Universal Sensor is designed for flexible installation. Always ensure power is disconnected before beginning any installation procedures.

설치 방법:

  • Conduit Installation: The stiff jacketed cable allows for easy pulling through conduit. Ensure the sensor tip is positioned correctly for accurate readings.
  • Domestic Hot Water Tank Wells: Insert the sensor tip into the designated temperature well of the hot water tank.
  • Pipe Strapping: For measuring supply or return temperatures, securely strap the sensor to the pipe. Ensure good thermal contact between the sensor tip and the pipe surface.

Connect the sensor wires to the appropriate terminals on your control system as per the system's wiring diagram. The sensor is a 10K thermistor type.

Tekmar 078 Universal Sensor with 15-foot wire, coiled.
An image showing the Tekmar 078 Universal Sensor. It features a gray, stiff jacketed cable coiled, with a small brass-colored sensor tip visible at one end. The cable is approximately 15 feet long.

작동 원리

The Tekmar 078 operates as a 10K thermistor, which changes its electrical resistance in response to temperature variations. This change in resistance is then interpreted by a compatible control system to provide an accurate temperature reading. Its fast response time ensures that temperature fluctuations are detected promptly.

유지

The Tekmar 078 Universal Sensor requires minimal maintenance. Regular inspection is recommended to ensure optimal performance:

  • 시각적 검사: Periodically check the cable and sensor tip for any signs of physical damage, wear, or corrosion. The brass sleeve is corrosion-resistant, but extreme conditions may still affect it over time.
  • 연결 무결성: Ensure all electrical connections remain secure and free from moisture or debris.
  • 청결: Keep the sensor tip clean from any buildup that might impede accurate temperature sensing.

Do not attempt to disassemble the sensor. If damage is observed, replace the unit.

문제 해결

If the sensor is not providing expected readings or appears to be malfunctioning, consider the following:

  • 연결 확인: Verify that all wiring connections are correct and secure at both the sensor and the control system.
  • 센서 배치: Ensure the sensor is properly positioned and has good thermal contact with the medium it is intended to measure. Incorrect placement can lead to inaccurate readings.
  • 케이블 무결성: Inspect the 15-foot cable for any cuts, pinches, or damage that could interrupt the signal.
  • Control System Compatibility: Confirm that the control system is compatible with a 10K thermistor type sensor.

If issues persist after checking these points, consult the control system's manual or contact Tekmar technical support.

명세서

기인하다세부 사항
상표테크마르
모델078
센서 유형10K 서미스터
정확성+/- 0.2 ° C
케이블 길이15 피트
재료Brass (corrosion-resistant sleeve)
품목 치수(L x W x H)1 x 1 x 1인치(제품 크기)
품목 무게2.12 온스
장착 유형Flange Mount (for sensor tip)
한국어:782301923355
인증CSA and C US Approved

보증 및 지원

For detailed warranty information regarding the Tekmar 078 Universal Sensor, please refer to the official documentation provided by Tekmar at the time of purchase or visit the manufacturer's web대지.

For technical assistance, installation queries, or troubleshooting support, please contact Tekmar customer service directly. Contact information can typically be found on the product packaging or the official Tekmar web대지.

관련 문서 - 078

사전view Installation and Operation Manual for tekmar Three Outdoor Sensor Module 081
This manual provides detailed installation and operation instructions for the tekmar Three Outdoor Sensor Module 081. It covers mounting, wiring, sensor testing, technical specifications, and warranty information for the module, which is designed to measure outdoor temperature using NTC thermistors.
사전view tekmar Universal Reset Control 363 사용자 브로셔
Comprehensive guide to the tekmar Universal Reset Control 363, detailing its features, user interface, access levels, and menu options for optimizing hydronic heating systems, including integration with RTUs.
사전view Smart Steam Control 289 | tekmar Advanced Steam Boiler Management
The tekmar Smart Steam Control 289 is an advanced, connected system for managing multiple steam boilers. It offers remote access via the Nexa app, up to 20% energy savings, a 5-inch touchscreen, and compatibility with optional sensors, making it ideal for commercial HVAC applications.
사전view Troubleshooting Guide for tekmar 422 Universal Reset Module
A comprehensive troubleshooting guide for the tekmar 422 Universal Reset Module, covering common issues like blank screens, sensor errors, boiler firing problems, and mixing control issues. Includes detailed steps and checks for diagnosing and resolving problems.
사전view Troubleshooting Guide for tekmar 423 Universal Reset Module
Comprehensive troubleshooting guide for the tekmar 423 Universal Reset Module, covering sensor inputs, sensor checks, outdoor sensor notes, bypassing outdoor sensor, boiler firing issues, mixing control problems, floating action valve checks, variable speed pump operation, bus configuration, and DHW settings. Includes a detailed sensor resistance table.
사전view tekmar WiFi Thermostat 562 User Manual
User manual for the tekmar WiFi Thermostat 562, detailing its features, setup, and operation for precise temperature control of heating and cooling systems, including remote access via mobile app and web대지.