소개
This manual provides essential instructions for the safe and efficient installation, operation, and maintenance of your MARS 10588 1/2 HP Furnace Blower Motor. Please read this manual thoroughly before attempting any installation or operation to ensure proper function and to prevent potential hazards.
The MARS 10588 is a 1/2 horsepower, 208-230 volt, 1075 RPM motor designed for furnace blower applications. It features a reversible rotation (REV RT) for versatile use.
안전 정보
WARNING: Electrical shock hazard. Disconnect power before servicing.
- Always disconnect power to the furnace or HVAC system before installing, servicing, or performing any maintenance on the motor.
- Installation and wiring should only be performed by a qualified technician in accordance with all local and national electrical codes.
- 감전을 방지하기 위해 모터가 제대로 접지되었는지 확인하십시오.
- 모터가 손상되었거나 배선이 노출된 경우에는 작동하지 마십시오.
- 설치 및 유지 보수 작업 중에는 안전 안경과 장갑과 같은 적절한 개인 보호 장비(PPE)를 착용하십시오.
- 작동 중에는 움직이는 부분에 손이나 헐렁한 옷을 가까이 두지 마십시오.
설정 및 설치
Careful installation is crucial for the longevity and performance of your blower motor.
풀기 및 검사
Upon receiving the motor, carefully inspect the packaging for any signs of damage. Remove the motor from its packaging and check for any physical damage, such as dents, bent shafts, or broken components. If damage is found, do not proceed with installation and contact your supplier.

Image 1: The MARS 10588 1/2 HP Furnace Blower Motor. This image displays the cylindrical motor housing, the extended shaft for fan blade attachment, and the mounting studs. The motor is black with a silver top plate, and a product label is visible on the side.
설치
- Ensure the mounting location is clean, dry, and free from obstructions.
- Mount the motor securely using the provided mounting studs or appropriate brackets. Ensure the motor is level and stable to prevent vibration and premature wear.
- Verify that the fan blade (not included) can be properly attached to the motor shaft and rotates freely without hitting any obstructions within the blower housing.
배선
CAUTION: Incorrect wiring can damage the motor and pose a fire hazard.
- 전원 공급 장치 볼륨tage는 모터의 정격 용량과 일치합니다.tage(208-230V).
- Refer to the wiring diagram on the motor's label for specific connections. Typically, these motors have multiple wires for different speeds and capacitor connections.
- Connect the appropriate capacitor (if external) as specified by the motor's label.
- 단락을 방지하기 위해 모든 전기 연결부가 단단히 고정되고 절연되어 있는지 확인하십시오.
- The motor is designed for reversible rotation. Follow the wiring diagram to achieve the desired rotation direction (clockwise or counter-clockwise) for your specific furnace application.
작동 지침
모터를 올바르게 설치하고 배선하면 바로 작동할 수 있습니다.
- Before restoring power, double-check all connections and ensure no tools or debris are left inside the blower housing.
- Restore power to the furnace or HVAC system.
- Initiate a test run of the furnace blower. Observe the motor for smooth operation, unusual noises, or excessive vibration.
- Verify that the fan blade is rotating in the correct direction and moving air effectively.
The motor is designed for continuous duty within its specified voltage and temperature ranges. Avoid operating the motor outside of these parameters.
유지
Regular maintenance helps extend the life of your MARS 10588 motor and ensures optimal performance.
- 연례 검사: At least once a year, inspect the motor for dust and debris accumulation. Clean the exterior of the motor using a soft brush or compressed air.
- 베어링 점검: Listen for any unusual noises from the bearings. If the motor has oil ports (check the motor label), apply a few drops of electric motor oil annually. Many modern blower motors are permanently lubricated and do not require additional oiling. Refer to the motor's specific label for lubrication requirements.
- 배선 검사: Check all electrical connections for tightness and signs of wear or corrosion.
- 진동 확인: Ensure the motor remains securely mounted and that there is no excessive vibration during operation. Tighten any loose mounting hardware.
IMPORTANT: Always disconnect power before performing any maintenance.
문제 해결
This section provides solutions to common issues you might encounter with your blower motor.
| 문제 | 가능한 원인 | 해결책 |
|---|---|---|
| 모터가 시동되지 않습니다 | 전원 공급이 없습니다 배선 불량 불량 커패시터 과부하 보호 장치가 작동됨 | 회로 차단기/퓨즈를 확인하세요 배선 연결 확인 콘덴서 테스트/교체 모터가 식을 때까지 기다린 후 막힘이 있는지 확인하십시오. |
| 모터는 윙윙거리지만 회전하지 않습니다. | 불량 커패시터 Obstructed shaft/bearings 잘못된 배선 | 콘덴서 테스트/교체 Check for obstructions, clean/lubricate bearings 배선도를 확인하십시오 |
| 과도한 소음 또는 진동 | 느슨한 장착 마모된 베어링 Unbalanced fan blade | 장착 하드웨어를 조이세요 Replace motor (if bearings are sealed) Inspect and balance fan blade |
| 모터가 과열됩니다 | 공기 흐름이 부족합니다 초과 적재 잘못된 볼륨tage | Clean blower housing/filter Ensure motor is not undersized for load 전원 공급 장치 볼륨 확인tage |
If these troubleshooting steps do not resolve the issue, contact a qualified HVAC technician or the manufacturer for assistance.
명세서
| 특징 | 세부 사항 |
|---|---|
| 상표 | 화성 |
| 모델 번호 | 10588 |
| 마력 (HP) | 0.5마력 (1/2마력) |
| 권tage | 208-230 볼트 |
| 속도 | 1075 RPM |
| 회전 | Reversible (REV RT) |
| 재료 | 구리(권선) |
| 품목 무게 | 15.2 온스 |
보증 및 지원
For specific warranty information, please refer to the documentation provided with your purchase or contact MARS directly. Typically, warranty coverage addresses manufacturing defects under normal use conditions.