HEWLETT PACKARD 462975-001

HP 512MB Battery Backed Write Cache Module (462975-001)

사용 설명서

1. 서론

This instruction manual provides essential information for the proper installation, operation, and maintenance of the HP 512MB Battery Backed Write Cache (BBWC) module, model 462975-001. This module is designed to enhance the performance and data integrity of HP SmartArray controllers by providing a temporary storage area for data before it is written to disk, and protecting this data during power outag에스.

Please read this manual thoroughly before proceeding with installation or operation to ensure safe and effective use of the product.

2. 안전 정보

부상 및 장비 손상을 방지하기 위해 다음 안전 수칙을 준수하십시오.

  • Always power off the server and disconnect all power cords before installing or removing any internal components.
  • 민감한 전자 부품의 정전기 방전(ESD) 손상을 방지하려면 정전기 방지 손목 스트랩을 착용하고 정전기 방지 매트에서 작업하세요.
  • Handle the module by its edges only. Avoid touching the gold connectors or integrated circuits.
  • Ensure proper ventilation around the server to prevent overheating.

3. 패키지 내용

패키지에 다음 품목이 포함되어 있는지 확인하세요.

  • HP 512MB Battery Backed Write Cache Module (462975-001)

If any components are missing or damaged, contact your vendor or HP support immediately.

4. 설정 및 설치

This section details the steps for installing the 512MB BBWC module into a compatible HP SmartArray controller.

4.1 설치 전 체크리스트

  1. Ensure the server is powered off and disconnected from all power sources.
  2. Open the server chassis according to the server's service manual.
  3. Locate the HP SmartArray controller where the BBWC module will be installed. Refer to your server's documentation for the exact location.
  4. Prepare an anti-static workspace.

4.2 모듈 설치

  1. Carefully remove the BBWC module from its anti-static packaging.
  2. Identify the BBWC slot on the SmartArray controller. This slot is typically a dedicated memory slot.
  3. Align the module with the slot, ensuring the gold connectors are correctly oriented. The module is keyed to fit in only one direction.
  4. Apply even pressure to both ends of the module until it is fully seated in the slot. You may hear a click as the retention clips engage.
  5. If your SmartArray controller uses a separate battery pack for the BBWC, connect the battery cable to the designated port on the controller or module. Ensure the connection is secure.
HP 512MB Battery Backed Write Cache Module, top view

그림 1: 상단 view of the HP 512MB BBWC module (462975-001) showing connectors and labels.

HP 512MB Battery Backed Write Cache Module, bottom view

그림 2: 하단 view of the HP 512MB BBWC module (462975-001) showing the circuit board.

4.3 설치 후

  1. Close the server chassis.
  2. Reconnect all power cords and power on the server.
  3. During server boot, observe the POST messages for any errors related to the SmartArray controller or BBWC module.

5. 모듈 작동 방법

The HP 512MB BBWC module operates automatically once installed and recognized by the SmartArray controller. Its primary function is to provide a non-volatile cache for write operations, improving disk I/O performance and protecting data in the event of a power failure.

5.1 Verifying Operation

To verify the module's operational status:

  • Access the SmartArray controller's configuration utility (e.g., during server boot via a key press, or through HP's management software like HP System Management Homepage).
  • Navigate to the controller's cache settings. The 512MB BBWC should be detected and reported as active.
  • Check the battery status within the utility. A newly installed battery may require a full charge cycle.

6. 유지관리

The BBWC module itself is generally maintenance-free. However, the associated battery pack has a finite lifespan and requires periodic monitoring and eventual replacement.

6.1 배터리 모니터링

  • Regularly check the battery status through the SmartArray controller's management utility.
  • Look for warnings or errors indicating a low charge, failed battery, or battery nearing end-of-life.
  • The typical lifespan of a BBWC battery varies but is generally several years.

6.2 배터리 교체

If the battery requires replacement:

  • Obtain a compatible replacement battery pack from HP or an authorized reseller.
  • Follow the safety precautions outlined in Section 2.
  • Power off the server and disconnect power.
  • Locate and disconnect the old battery pack.
  • Connect the new battery pack, ensuring proper orientation and secure connection.
  • 폐배터리는 지역 규정에 따라 책임감 있게 폐기하십시오.
  • Power on the server and verify the new battery status in the controller utility.

7. 문제 해결

이 섹션에서는 일반적인 문제에 대한 기본적인 문제 해결 단계를 제공합니다.

7.1 모듈이 감지되지 않음

  • 좌석 확인: Power off the server, open the chassis, and ensure the BBWC module is fully and correctly seated in its slot.
  • 호환성 확인: Confirm that the module (462975-001) is compatible with your specific SmartArray controller model and server.
  • 손상 여부 검사: Visually inspect the module and controller slot for any physical damage or bent pins.
  • 펌웨어 업데이트 : Ensure your SmartArray controller's firmware is up to date. Outdated firmware can sometimes cause detection issues.

7.2 Battery Errors

  • 연결 확인: Ensure the battery cable is securely connected to both the battery pack and the controller/module.
  • Allow Charge Cycle: A new battery may take several hours to fully charge. Monitor its status over time.
  • 베터리 교체: If errors persist after checking connections and allowing a charge cycle, the battery pack may be faulty and require replacement.

For more complex issues, refer to your SmartArray controller's documentation or contact HP technical support.

8. 사양

특징설명
모델 번호462975-001
상표HEWLETT PACKARD (HP)
메모리 크기512메가바이트
유형Battery Backed Write Cache (BBWC) Module
호환성Designed for HP SmartArray controllers (e.g., DL380 G6 cto)
품목 무게3.52 온스(약 100그램)

9. 보증 및 지원

This HP product is covered by a limited warranty. For specific warranty terms and conditions, please refer to the documentation included with your original server or SmartArray controller, or visit the official HP support web대지.

For technical assistance, product information, or to report issues, please contact HP customer support through their official channels. Have your product model number (462975-001) and server serial number ready when contacting support.

HP 지원 Web대지: www.hp.com/support

관련 문서 - 462975-001

사전view HP 3458A 디지털 멀티미터 부품별 정보 패킷
이 문서는 휴렛팩커드(HP) 3458A 디지털 멀티미터에 대한 회로도, 부품 위치, 부품 목록을 포함한 상세한 부품 수준 수리 정보를 제공합니다. 또한 수리 전략의 역사와 부품 수준 정보 패킷(CLIPS)의 내용에 대해서도 설명합니다.
사전view Hewlett-Packard HP 5382A Frequency Counter: Operating and Service Manual
This document is the operating and service manual for the Hewlett-Packard HP 5382A Frequency Counter, detailing its specifications, installation, operation, and maintenance procedures. Originally published in May 1974.
사전view HP 8657D Signal Generator: Operation and Calibration Manual
Comprehensive operation and calibration manual for the Hewlett-Packard HP 8657D π/4 DQPSK Signal Generator, detailing installation, operation, performance testing, and adjustments.
사전view HP 8657D π/4 DQPSK 신호 발생기: 작동 및 교정 설명서
이 종합 설명서는 옵션 001을 포함하여 Hewlett-Packard HP 8657D π/4 DQPSK 신호 발생기의 작동, 교정, 사양 및 성능 테스트에 대한 자세한 정보를 제공합니다.
사전view TB 9-4931-488-35: Calibration Procedure for Signal Generators
Detailed calibration procedure for Hewlett-Packard Model 8640B signal generators, including models SG1112VIU, SG1112V2U, and MIS-28707TY2, with various options. This technical bulletin provides step-by-step instructions for ensuring accurate performance.
사전view HP 8657A Synthesized Signal Generator Service Manual
Service manual for the Hewlett-Packard HP 8657A Synthesized Signal Generator, covering operation, safety, and replaceable parts with detailed listings.