1. 서론
This manual provides detailed instructions for the safe installation, operation, and maintenance of the Leviton 15 Amp, 125 Volt, Industrial Series Extra Heavy Duty Grade, 4-In-1 Receptacle, Model 1254-R. This device is designed for demanding environments requiring high-abuse tolerance, such as healthcare facilities, manufacturing plants, and educational institutions. It features four outlets in a single-gang footprint, offering increased power access without requiring larger electrical boxes.
2. 안전 정보
경고: To avoid fire, shock, or death, turn off power at the circuit breaker or fuse box and test that power is off before wiring. All wiring must be in accordance with national and local electrical codes. If you are unsure about any part of these instructions, consult a qualified electrician.
- Always disconnect power before servicing or installing the receptacle.
- 습기가 많은 장소에는 해당 용도로 특별히 제작된 제품이 아닌 이상 설치하지 마십시오.
- 모든 전선 연결이 안전하고 적절하게 절연되어 있는지 확인하세요.
- Use only copper wire with this device.
- This device is rated for 15 Amp, 125 Volt applications. Do not exceed these ratings.
3. 패키지 내용
The package for the Leviton 1254-R 4-in-1 Receptacle typically includes:
- One (1) Leviton 1254-R 4-In-1 Receptacle
- 장착 나사(일반적으로 2개)
4. 사양
| 특징 | 세부 사항 |
|---|---|
| 모델 번호 | 1254-R |
| Amp에라 지 | 15 Amp |
| 권tage | 125볼트 |
| 등급 | Industrial Series Extra Heavy Duty Grade |
| 리셉터클 유형 | 4-In-1, Straight Blade, Grounding |
| 색상 | 빨간색 |
| 재료 | Thermoplastic Nylon (Cover and Body) |
| 배선 옵션 | Back and Side Wiring |
| 콘택트 렌즈 | Extra Heavy-Duty, T-type triple-wipe bronze |
| 치수 | 약 8 x 8 x 8인치(제품 치수) |
| 무게 | 약 6.4온스 |
5. 설치
Follow these steps for proper installation of your Leviton 4-in-1 Receptacle. If you are not familiar with electrical wiring, consult a qualified electrician.
- 전원 끄기: Locate the circuit breaker or fuse that controls the outlet where you intend to install the receptacle. Turn it OFF. Verify that the power is off using a voltag전자 테스터.
- (해당되는 경우) 기존 용기를 제거하십시오. Unscrew the wall plate and then the mounting screws holding the existing receptacle in the electrical box. Carefully pull the old receptacle out of the box.
- 전선 분리: Disconnect the wires from the old receptacle. Note which wire was connected to which terminal (hot, neutral, ground).
- 전선 준비: Strip approximately 1/2 inch of insulation from the ends of the wires if necessary. Ensure the wire ends are clean and straight.
- Connect Wires to New Receptacle:
- 연결하다 HOT (Black or Red) ~에 전선을 연결하다 놋쇠 단자나사.
- 연결하다 중립(흰색) ~에 전선을 연결하다 은 단자나사.
- 연결하다 GROUND (Green or Bare Copper) ~에 전선을 연결하다 녹색 접지 나사.
This receptacle supports both back-wiring (inserting wires into holes on the back and tightening screws) and side-wiring (wrapping wires around terminal screws). Ensure connections are tight and no bare wire is exposed outside the terminals.

이미지 5.1: 앞면 view of the Leviton 1254-R 4-in-1 Receptacle in Red. This image shows the four outlets and the robust construction.

이미지 5.2: 클로즈업 view of a Leviton receptacle's wiring terminals, illustrating the side-wiring option and the grounding screw.
- 마운트 수용기: Carefully push the wired receptacle back into the electrical box. Secure it with the provided mounting screws.
- 벽면 플레이트 설치: Attach the wall plate over the receptacle.
- 복원력 : Turn the circuit breaker or fuse back ON.
- 시험: Plug a device into each of the four outlets to ensure proper function.
The 1254-R features an interlocking thermoplastic nylon cover and body for enhanced durability and a nickel-plated brass strap with integral ground contacts for reliable grounding. The permanent "Green Dot" marking on the face indicates its hospital/industrial grade compliance.

Image 5.3: Detail showing the "Green Dot" marking, signifying the industrial/hospital grade rating of the receptacle.
6. 운영
The Leviton 1254-R 4-in-1 Receptacle operates like any standard electrical outlet. Simply insert the plug of your electrical device into one of the four available receptacles. Ensure the plug is fully inserted for a secure connection. The extra heavy-duty, T-type triple-wipe bronze contacts provide maximum performance and a strong grip on cords.
7. 유지관리
This industrial-grade receptacle requires minimal maintenance. Periodically inspect the receptacle for any signs of damage, such as cracks, discoloration, or loose connections. If any damage is observed, turn off power at the circuit breaker and replace the receptacle immediately. Clean the surface with a soft, dry cloth. Do not use abrasive cleaners or solvents.
8. 문제 해결
| 문제 | 가능한 원인 | 해결책 |
|---|---|---|
| 콘센트에 전원이 없습니다. | Circuit breaker tripped or fuse blown. Loose wiring connection. | Check and reset the circuit breaker or replace the fuse. Turn off power and inspect wiring connections for tightness. |
| Device plug feels loose in the outlet. | Worn contacts (unlikely for new industrial grade). Incorrect plug type. | Ensure the plug is fully inserted. If the issue persists, and the receptacle is old, consider replacement. Verify plug compatibility. |
| Receptacle is warm to the touch. | Overload on the circuit. Loose wiring connection. | Disconnect some devices to reduce load. Turn off power and check wiring connections. If warming persists, consult an electrician. |
9. 보증 정보
Leviton products are backed by a limited warranty. For specific warranty terms and conditions applicable to the 1254-R receptacle, please refer to the warranty documentation included with your purchase or visit the official Leviton web사이트. 보증 청구를 위해 구매 증빙 자료를 보관하세요.
10. 지원
For technical assistance, product information, or customer support, please visit the official Leviton web해당 웹사이트를 방문하거나 고객 서비스 부서에 문의하십시오. 연락처 정보는 일반적으로 제품 포장이나 Leviton 제품 설명서에서 확인할 수 있습니다. web대지.
레비톤 Web대지: www.leviton.com