1. 서론

This manual provides instructions for the installation, operation, and maintenance of your StarTech.com 8 Outlet Horizontal 1U Rack Mount PDU Power Strip (Model RKPW081915). This Power Distribution Unit (PDU) is designed to provide reliable power distribution and surge protection for equipment within network server racks and cabinets.

2. 안전 정보

경고: 이러한 안전 지침을 따르지 않을 경우 화재, 감전 또는 기타 부상이나 손상이 발생할 수 있습니다.

3. 패키지 내용

StarTech.com RKPW081915 PDU and Instruction Manual in packaging

Image: The StarTech.com PDU and its instruction manual, as typically found in the product packaging.

  • 1x 8 Outlet Horizontal 1U Rack Mount PDU Power Strip (RKPW081915)
  • 1x 사용 설명서

4. 제품 오버view

The StarTech.com RKPW081915 is a 1U horizontal rack-mountable PDU designed for efficient power distribution in server environments. It features 8 NEMA 5-15R outlets, a 6-foot power cord, and built-in surge protection.

전면 패널 기능

앞면과 뒷면 view of the StarTech.com RKPW081915 PDU with labeled components

이미지: 상세 view of the PDU's front and back, highlighting the LED indicators, power switch, and outlets.

  • LED Surge Indicator: 서지 보호 기능이 작동 중일 때 표시등이 켜집니다.
  • LED Ground Indicator: Illuminates when the PDU is properly grounded.
  • Power/Reset Switch: Controls power to all outlets and acts as a circuit breaker reset.

후면 패널 기능

뒤쪽 view of the StarTech.com RKPW081915 PDU showing the 8 NEMA 5-15R outlets and power cord

Image: Close-up of the rear of the PDU, displaying the eight power outlets and the attached power cord.

5. 설정

5.1 풀기

Carefully remove the PDU and all components from the packaging. Inspect for any damage during shipping. If any damage is found, contact your vendor immediately.

5.2 랙 마운팅

The RKPW081915 PDU is designed for horizontal mounting in any standard 19-inch server rack that is 4 inches (10.16 cm) deep or greater. It occupies 1U of rack space.

  1. Align the mounting ears of the PDU with the desired rack unit (U) on your server rack.
  2. Secure the PDU to the rack using appropriate rack screws (not included). Ensure both sides are firmly attached.
StarTech.com RKPW081915 PDU installed horizontally in a server rack

Image: The PDU mounted horizontally within a server rack, demonstrating its 1U form factor and integration with other equipment.

StarTech.com RKPW081915 PDU with dimensions and rack compatibility information

Image: A visual representation of the PDU's height (1U) and cable length (6ft), confirming its compatibility with standard 19-inch racks.

5.3 장치 연결

  1. Ensure the PDU's power/reset switch is in the OFF position.
  2. Plug the power cords of your network and server equipment into the 8 NEMA 5-15R outlets on the rear of the PDU.
  3. Connect the integrated 6-foot power cord of the PDU to a grounded 120V/15A power source.

Video: Demonstrates the installation of a rack-mounted power strip, showing how it integrates into a server rack and connects to devices.

Video: An official product video from StarTech.com showcasing the 8 Outlet Horizontal 1U Rack Mount PDU Power Strip for network server racks, highlighting its surge protection features.

Video: A demonstration of the StarTech 8 Outlet Horizontal 1U Rack Mount PDU, showing its physical attributes and how it fits into a rack setup.

비디오: 오버view of an 8 Outlet Rack-Mount PDU, detailing its features and benefits for organizing power in a rack system.

Video: A demonstration of a PDU Outlet Horizontal, highlighting its design and functionality for power distribution.

6. 사용 설명서

6.1 전원 켜기/끄기

To power on the connected equipment, press the Power/Reset switch on the front panel to the ON position. To power off, press the switch to the OFF position.

6.2 LED 표시등

6.3 회로 차단기

The Power/Reset switch also functions as a circuit breaker. If an overload occurs, the switch will trip to the OFF position, cutting power to all connected devices to prevent damage. To reset the circuit breaker, reduce the load on the PDU and then press the switch back to the ON position.

7. 유지관리

7.1 청소

To clean the PDU, ensure it is powered off and disconnected from the main power source. Use a soft, dry cloth to wipe the exterior. Do not use liquid cleaners or aerosols.

7.2 정기점검

8. 문제 해결

문제가능한 원인해결책
연결된 장치에 전원이 공급되지 않습니다.PDU is off or circuit breaker tripped.Ensure the Power/Reset switch is ON. If it tripped, reduce the load and reset the switch.
접지 LED가 꺼져 있습니다.부적절한 접지.Ensure the PDU is plugged into a properly grounded outlet. Check the building's electrical wiring.
서지 LED가 꺼져 있습니다.서지 보호 기능이 손상되었습니다.The PDU's surge protection may no longer be active. Replace the unit to ensure continued protection.
Devices are not receiving enough power.PDU is overloaded.Reduce the total power draw of connected devices to stay within the 15A limit.

9. 사양

특징세부 사항
모델 번호RKPW081915
상표StarTech.com
총 전원 콘센트8 x NEMA 5-15R
입력 Voltage120 볼트 AC
현재 평가15 Amps
전원 코드 길이6피트(1.8미터)
Rack Unit (RU)1U
설치Horizontal 19-inch Rack Mount
치수(길이x너비x높이)19 x 3.76 x 1.68인치(48.26 x 9.55 x 4.27cm)
품목 무게4.85파운드(2.2kg)
특별 기능Mountable, On/Off Switch, Surge Protection, Built-in Circuit Breaker
Casing 재료Rugged Steel

10. 보증 및 지원

This StarTech.com product is backed by a lifetime warranty, ensuring long-term reliability and peace of mind. In addition, free lifetime 24/5 multi-lingual technical assistance is available to help you with any questions or issues you may encounter.

For technical support or warranty claims, please visit the official StarTech.com web해당 웹사이트를 방문하거나 고객 서비스 센터에 직접 문의하십시오. 보증 적용을 위해 구매 영수증을 보관하십시오.