소개
The Samson Rubicon R5a Active Ribbon Studio Monitors are designed to provide accurate and natural sound reproduction for professional audio environments. This manual provides essential information for the proper setup, operation, and maintenance of your R5a monitors.
Each R5a monitor features a bi-amplified design, delivering 50 watts to a 5-inch inverted cone low-frequency driver and 25 watts to a 2-inch Velocity Ribbon high-frequency transducer. The monitors are housed in a shelf-ported wood enclosure and offer balanced 1/4-inch and XLR input connections. A 4-segment high-frequency lift control allows for precise adjustment of the ribbon tweeter output.
중요 안전 지침
Please read these instructions carefully before operating your Samson Rubicon R5a monitors. Keep this manual for future reference.
- 전원: Connect the unit only to a power supply of the type described in this operating instruction or marked on the unit.
- 통풍: 환기구를 막지 마십시오. 제조업체의 지침에 따라 설치하십시오.
- 열: 라디에이터, 난방 조절기, 스토브 또는 기타 장치(다음을 포함)와 같은 열원 근처에 설치하지 마십시오. amp열을 생성하는 발전기.
- 물과 습기: 이 기기를 물 근처에서 사용하지 마십시오.
- 청소: 마른 천으로만 닦으십시오.
- 서비스: 모든 서비스는 자격을 갖춘 서비스 담당자에게 의뢰하십시오. 전원 코드나 플러그가 손상되었거나, 액체가 쏟아졌거나, 물체가 기기에 떨어졌거나, 기기가 비나 습기에 노출되었거나, 정상적으로 작동하지 않거나, 떨어졌을 때와 같이 기기가 어떤 식으로든 손상된 경우 서비스가 필요합니다.
패키지 내용
패키지에 다음 품목이 포함되어 있는지 확인하십시오.
- Samson Rubicon R5a Active Ribbon Studio Monitors (Pair)
- 전원 케이블 (2)
- 사용 설명서 (본 문서)
설정
놓기
Proper placement of your studio monitors is crucial for accurate sound reproduction. Position the monitors to form an equilateral triangle with your listening position. The tweeters should be at ear level. Avoid placing monitors directly against walls or in corners, as this can exaggerate bass frequencies.

이미지: 앞면 view of a Samson Rubicon R5a Active Ribbon Studio Monitor. It shows the 5-inch woofer, the 2-inch ribbon tweeter, and the Samson logo.
사이
The Rubicon R5a monitors offer balanced 1/4-inch and XLR input connections. Use high-quality shielded cables to connect your audio source (e.g., audio interface, mixer) to the monitors.
- Ensure both the monitors and your audio source are powered off before making any connections.
- Connect the audio output from your source to the XLR or 1/4-inch input on each R5a monitor.
- Connect the supplied power cables to the IEC power inlets on the rear of each monitor and then to a suitable AC power outlet.
- Once all connections are secure, you can proceed to power on your equipment. It is recommended to power on your audio source first, then the monitors. When powering off, turn off the monitors first, then the audio source.
작동 지침
전원 켜기/끄기
Locate the power switch on the rear panel of each monitor. Flip the switch to the "ON" position to power on the monitor. An indicator light on the front panel will illuminate. To power off, flip the switch to the "OFF" position.
볼륨 조절
Each R5a monitor has a volume control knob on the rear panel. Start with the volume set to a low level before playing audio. Gradually increase the volume to your desired listening level. It is generally recommended to control the overall system volume from your audio source (e.g., audio interface, mixer) and use the monitor's volume control for fine-tuning or balancing.
High-Frequency Lift Control
The R5a monitors feature a 4-segment high-frequency lift control. This allows you to adjust the output level of the ribbon tweeter to compensate for room acoustics or personal preference. Experiment with the different settings to find the optimal balance for your listening environment.
The settings typically include:
- 0dB: 무반응.
- +2dB: Slight boost in high frequencies.
- +4dB: Moderate boost in high frequencies.
- -2dB: Slight cut in high frequencies.
유지
To ensure the longevity and optimal performance of your Samson Rubicon R5a monitors, follow these maintenance guidelines:
- 청소: Dust the monitors regularly with a soft, dry cloth. Do not use liquid cleaners or solvents, as these can damage the finish or internal components.
- 통풍: Ensure that the ventilation openings on the rear of the monitors are not obstructed. Adequate airflow is essential to prevent overheating.
- 저장: If storing the monitors for an extended period, keep them in a dry, temperature-controlled environment, ideally in their original packaging or a protective case.
- 과부하를 피하세요: Do not operate the monitors at excessively high volumes for prolonged periods, as this can cause damage to the drivers.
문제 해결
| 문제 | 가능한 원인 | 해결책 |
|---|---|---|
| No sound from monitor. |
|
|
| 왜곡된 소리. |
|
|
| Hum or buzz. |
|
|
If the problem persists after trying these solutions, please contact Samson customer support or a qualified service technician.
명세서
| 특징 | 세부 사항 |
|---|---|
| 모델명 | Rubicon R5a |
| 스피커 유형 | Active Ribbon Studio Monitor |
| 저주파 드라이버 | 5-inch inverted cone |
| 고주파 변환기 | 2-inch Velocity Ribbon |
| LF Amplifier 힘 | 50 와트 |
| HF Amplifier 힘 | 25 와트 |
| 총 출력 전력 | 75와트(바이-)amp에드) |
| 연결 기술 | XLR, 1/4-inch (balanced) |
| 전원 | 코드식 전기 |
| 인클로저 유형 | Shelf-ported wood enclosure |
| High-Frequency Control | 4-segment lift control |
| 한국어: | 809164005148 |
보증 정보
Samson Technologies warrants its products to be free from defects in materials and workmanship for a period of one (1) year from the date of original purchase. This warranty is non-transferable and applies only to the original purchaser.
This warranty does not cover damage resulting from accident, misuse, abuse, alteration, or unauthorized service. For full warranty terms and conditions, please refer to the official Samson web사이트를 방문하거나 고객 지원팀에 문의하세요.
고객 지원
For technical support, service, or warranty inquiries, please contact Samson Customer Service:
- Web대지: www.samsontech.com/support
- 핸드폰: Refer to the Samson web지역 연락처 사이트.
- 주소: Samson Technologies Corp., 278-B Duffy Ave, Hicksville, NY 11801, USA
When contacting support, please have your product model (Rubicon R5a) and serial number available.