레비톤 2610 30 Amp 125V Flush Mount Locking Receptacle User Manual

1. 서론

The Leviton 2610 is an industrial-grade flush mounting locking receptacle designed for reliable electrical connections. This 30 Amp, 125 Volt device ensures secure power delivery in demanding environments, preventing accidental disconnection of power cords. It is built with high-quality materials to provide superior performance and dependability.

레비톤 2610 30 Amp 125V Flush Mount Locking Receptacle

이미지 1.1: 앞면 view of the Leviton 2610 30 Amp 125V Flush Mount Locking Receptacle.

2. 안전 정보

경고: Risk of electric shock. Improper installation or use can result in serious injury or death. Always follow these safety guidelines:

3. 제품 특징

4. 사양

모델 번호2610
상표레비톤
전기 등급30 Amp, 125볼트
구성3-Wire, Grounding
장착 유형플러시 마운트
색상검은색
재료단단한
제품 치수1.3인치 길이 x 3.5인치 너비
품목 무게3.68 온스
제조업체LEVITON MFG CO INC

5. 설정 및 설치

Installation of this electrical device should only be performed by a qualified electrician. Adherence to all national and local electrical codes is mandatory.

  1. 전원 분리: Before beginning any work, ensure the power supply to the circuit is completely disconnected at the main circuit breaker or fuse box. Use a voltag회로의 전원이 차단되었는지 확인하기 위해 테스터를 사용합니다.
  2. 배선 준비: Strip insulation from the circuit wires (hot, neutral, ground) to the appropriate length as specified by the receptacle's terminals. Ensure only copper conductors are used.
  3. 전선 연결: Connect the wires to the corresponding terminals on the Leviton 2610 receptacle. Typically, the hot wire connects to the brass terminal, the neutral wire to the silver terminal, and the ground wire to the green terminal. Tighten all terminal screws securely.
  4. 마운트 수용기: Carefully fold the wires into the electrical box and secure the receptacle to the box using the provided mounting screws. Ensure the receptacle is flush with the wall surface.
  5. 커버 플레이트 설치: Attach a compatible cover plate (sold separately) over the installed receptacle.
  6. 복원력 : Once installation is complete and all connections are secure, restore power at the circuit breaker and test the receptacle for proper operation.

6. 사용 설명서

To use the Leviton 2610 locking receptacle:

  1. 플러그 삽입: Align the blades of the compatible locking plug with the corresponding slots on the receptacle.
  2. Lock Plug: Insert the plug fully into the receptacle. Once inserted, twist the plug clockwise until it locks securely into place. This locking action prevents accidental disconnections.
  3. 플러그를 뽑으세요: To disconnect, twist the plug counter-clockwise to unlock it, then pull the plug straight out from the receptacle.

7. 유지관리

Regular inspection and basic maintenance can help ensure the longevity and safe operation of your Leviton 2610 receptacle:

8. 문제 해결

If you encounter issues with your Leviton 2610 receptacle, consider the following:

9. 보증 및 지원

For detailed warranty information, technical support, or to find authorized service centers, please visit the official Leviton website or contact Leviton customer service directly. Keep your purchase receipt as proof of purchase for any warranty claims.

관련 문서 - 2610

사전view Leviton GFCI 콘센트 설치 및 테스트 가이드
Leviton SmartLock Pro GFCI 콘센트의 설치 및 테스트 방법에 대한 종합 가이드로, 배선 지침, 안전 예방 조치 및 문제 해결 팁을 포함합니다.
사전view USB 포트가 있는 Leviton GFCI 콘센트 설치 및 작동 설명서
배선 지침, 안전 경고, 테스트 절차 및 보증 정보를 포함하여 USB 포트가 있는 Leviton GFCI 콘센트를 설치하고 작동하는 데 대한 포괄적인 가이드입니다.
사전view Leviton 스마트 GFCI 콘센트 설치 및 테스트: 종합 가이드
Leviton 스마트 GFCI 콘센트(모델 D2GF1, D2GF2) 설치 및 테스트 방법에 대한 단계별 안내입니다. GFCI 기능, 배선, 문제 해결 및 안전 수칙에 대해 알아보세요.
사전view Leviton SmartlockPro GFCI 콘센트 설치 및 테스트 가이드
Leviton SmartlockPro 누전 차단기(GFCI) 콘센트 설치 및 테스트에 대한 종합 가이드입니다. 안전 예방 조치, 배선, 문제 해결 및 제품 기능을 다룹니다.
사전view Leviton 상업용 및 산업용 스위치 선택 가이드
토글, Decora Plus, Lev-lok, 항균 및 특수 스위치 유형을 포함한 상업용 및 산업용 스위치에 대한 자세한 설명과 함께 애플리케이션 세부 정보 및 배선 다이어그램을 제공하는 Leviton의 포괄적인 선택 가이드입니다.
사전view Leviton EV40P EV 시리즈 40 AMP 플러그인 충전기 설치 설명서
Leviton EV40P EV 시리즈 40 설치 설명서 AMP 플러그인 전기차 충전기. 안전 경고, 사양, 설치 단계, 작동 절차, RFID 카드 사용법, 오류 메시지, 유지 보수 및 보증 정보가 포함되어 있습니다.