This manual provides essential information for the proper installation, operation, and maintenance of the Fujitsu S26113-E567-V50-02 DPS-500XB A Server Power Supply. This unit is designed to provide stable and reliable power to compatible server systems. Please read this manual thoroughly before installation and use.
명세서
The following table details the technical specifications of the Fujitsu S26113-E567-V50-02 DPS-500XB A Power Supply:
| 특징 | 세부 사항 |
|---|---|
| 모델 번호 | S26113-E567-V50-02, DPS-500XB A |
| 제조업체 | Fujitsu Technology Solutions |
| 최대 출력 전력 | 500와트 |
| 교류 입력 | 100-240V~, 7-3.5A, 50-60Hz |
| DC Output +12V1 | 17A (18A 20SEC) |
| DC Output +12V2 | 17A (18A 20SEC) |
| DC Output +12V3 | 15A (18A 20SEC) |
| DC Output +12V4 | 15A (18A 20SEC) |
| DC Output +12V5 | 17A (18A 20SEC) |
| DC Output +12V6 | 0.5A (1A 20SEC) |
| AUX DC Output +12V | 1A |
| AUX DC Output +5V | 2A |
| 직류 출력 +11V | 2A (2.5A 1SEC) |
| 팬들 | 1 |
| PFC 유형 | 활동적인 |
| CPU 전원 커넥터 | 4핀 |
| 애플리케이션 | 데스크탑 |
| 모듈식 | 비모듈식 |
| 80 PLUS 인증 | 금 |
| 기원 | 중국 본토 |
| 상태 | Second hand, Tested working 100% |
설정 및 설치
Proper installation is crucial for the safe and efficient operation of your power supply. Always ensure the server system is powered off and disconnected from the main power source before beginning installation.
- 안전이 최우선입니다. Disconnect all power cables from the server and ensure no residual power remains. Wear an anti-static wrist strap to prevent electrostatic discharge (ESD) damage to components.
- 기존 파워서플라이를 제거하십시오(해당되는 경우): Carefully disconnect all cables from the existing power supply unit (PSU). Unscrew and remove the old PSU from the server chassis.
- 새 PSU 설치: Gently slide the Fujitsu DPS-500XB A power supply into the designated PSU bay in your server chassis. Ensure it is seated correctly and align the screw holes.
- 안전한 전원 공급 장치: Use the appropriate screws to firmly secure the power supply to the server chassis.
- 전원 케이블 연결:
- Connect the main ATX power connector to the motherboard.
- Connect the 4-pin CPU power connector to the motherboard.
- Connect any necessary peripheral power cables (SATA, Molex, PCIe, etc.) to your drives, expansion cards, and other components. Ensure all connections are firm and correctly oriented.
- 케이블 관리 : Route cables neatly to improve airflow and prevent interference with other components.
- 최종 확인: Double-check all connections to ensure they are secure and correctly installed.
- 전원 켜기: Connect the server's power cord to the PSU and then to a grounded electrical outlet. Power on the server.
작동 지침
Once installed, the power supply operates automatically to deliver power to your server components. No specific user interaction is typically required during normal operation.
- 전원 켜기/끄기: The power supply is controlled by the server's power button and operating system. Ensure the server is properly shut down before disconnecting power.
- 통풍: Ensure the server chassis has adequate ventilation to allow proper airflow for the power supply's cooling fan. Blocked vents can lead to overheating and component failure.
- 안정적인 전원: Connect the server to a stable and grounded power outlet. Using a surge protector or Uninterruptible Power Supply (UPS) is recommended to protect against power fluctuations.
유지
Regular, simple maintenance can extend the lifespan of your power supply and ensure optimal performance.
- 먼지 제거: Periodically clean dust from the power supply's fan and ventilation grilles using compressed air. Ensure the server is powered off and unplugged before cleaning.
- 케이블 검사: Occasionally check power cables for any signs of wear, fraying, or damage. Replace damaged cables immediately.
- 환경 조건: Operate the server in a clean, dry, and well-ventilated environment within recommended temperature ranges to prevent overheating.
문제 해결
전원 공급 장치에 문제가 발생하면 다음의 일반적인 문제 해결 단계를 참조하십시오.
- 전원 없음:
- 전원 코드가 PSU와 벽면 콘센트에 모두 단단히 꽂혀 있는지 확인하세요.
- 다른 장치를 연결하여 벽면 콘센트가 작동하는지 확인하세요.
- Check all internal power connections (motherboard, CPU, peripherals) are firmly seated.
- 시스템 불안정/무작위 종료:
- This could indicate an overloaded or failing PSU. Ensure your system's power requirements do not exceed the PSU's 500W capacity.
- Check for overheating. Ensure proper ventilation and clean any dust from the PSU fan.
- 큰 팬 소음:
- Excessive fan noise can be caused by dust accumulation. Clean the fan blades and grille.
- If the noise persists, the fan bearing might be failing, which could require professional service or replacement.
- 타는 냄새:
- Immediately power off and unplug the server. Do not attempt to use it. This indicates a serious electrical fault and requires professional inspection.
사용자 팁
- Given this is a second-hand unit, it's advisable to perform a thorough visual inspection for any physical damage or signs of wear before installation.
- Always ensure compatibility with your server's motherboard and chassis form factor before attempting installation.
- When replacing a power supply, take note of the original cable routing to simplify the installation of the new unit.
보증 및 지원
This product comes with a 3-month warranty period, effective from the date the package is delivered. The warranty covers manufacturing defects and operational failures under normal use.
- 보증 제외 사항: The warranty is void if the product is damaged due to improper use, unauthorized modifications, or physical abuse.
- 기술 지원: For technical assistance or warranty claims, please contact your vendor or the original manufacturer, Fujitsu Technology Solutions.
- 반품 및 환불 정책: For details regarding returns and refunds, please refer to the specific policy provided by your seller at the time of purchase.