Universal ZL-R200A

ZL-R200A 공기열원 히트펌프 온수기 컨트롤러 사용 설명서

Model: ZL-R200A (New Version)

1. 서론

This manual provides detailed instructions for the installation, operation, and maintenance of the ZL-R200A Universal Air Source Heat Pump Water Heater Controller. This multi-function controller is designed to optimize the performance and efficiency of air-source heat pump water heaters, offering features such as auxiliary heating, waterflow auditing, ventilation pump control, and various protection mechanisms.

Please read this manual thoroughly before installation and operation to ensure safe and correct usage of the product.

2. 주요 특징

  • 다기능 디자인: Includes waterflow auditing, ventilation pump control, and sensor failure action functions.
  • Temperature Inquiry: Allows checking temperatures from all sensors, with results displayed for 3 seconds.
  • 수온 설정: Adjustable temperature range from 10℃ to 70℃ (factory default 40℃).
  • 두 가지 작동 모드: "AUTO" mode for continuous heating based on settings, and "SAVE" mode for heating only within three predefined time periods.
  • Multiple Control Functions: Manages temperature, auxiliary electrical heaters, and water ventilation pump.
  • Winter Antifreeze & Auto Defrost:
    • Antifreeze pumping activates when outdoor temperature ≤ 2℃ (pump runs 3 minutes every 30 minutes), stopping when ≥ 3℃.
    • Auto defrost starts at -9~0℃ and stops at 2-30℃.
  • Multiple Protections & Warning: Features exhaust temperature protections, high/low pressure warnings, compressor delay protections, and water sensor failure warnings.
  • Auto Restart & Restore: Automatically restarts after power loss, retains power failure memory, and supports recovery to factory settings.
ZL-R200A Controller Display and Internal Board
Figure 1: ZL-R200A Controller Display and Internal Control Board. Illustrates the multifunction design with waterflow auditing, ventilation pump control, and sensor failure actions.
ZL-R200A Controller Dimensions
Figure 2: Dimensions of the ZL-R200A display panel (86x86mm) and mainboard (105x90x35mm).
ZL-R200A Controller with Specifications Overlay
Figure 3: ZL-R200A controller with an overlay of key specifications for quick reference.

3. 설치 및 배선

Proper installation and wiring are critical for the safe and correct operation of the ZL-R200A controller. It is recommended that installation be performed by a qualified technician.

3.1 일반 예방 조치

  • The panel should be installed indoors, not outdoors.
  • Do not plug in/out panel bundle with power supplied.
  • All sensors must be installed at correct positions.
  • Ensure U34 is set correctly; otherwise, the system will not work.

3.2 배선도

Refer to the diagram below for correct wiring connections. Ensure all connections are secure and follow local electrical codes.

ZL-R200A Wiring Diagram
Figure 4: Wiring diagram for the ZL-R200A controller, showing connections for power (220VAC N/L), compressor, heater, valve, fan, pump, and various sensors (water, exhaust, outdoor, pressure, flowing).

4. 운영

The ZL-R200A controller features an intuitive display and buttons for easy operation.

4.1 제어판 이상view

ZL-R200A Control Panel
그림 5: 전면 view of the ZL-R200A control panel with its LCD display and control buttons.

4.2 수온 설정

The water temperature can be set within a range of 10℃ to 70℃. The factory default setting is 40℃.

4.3 작업 모드

The controller offers two primary working modes:

  • "AUTO" Mode: The system maintains heating according to the set temperature.
  • "SAVE" Mode: Heating is restricted to three predefined time periods. This mode is designed for energy saving.

To switch between "AUTO" and "SAVE" modes, press the M key. When "Auto restart function" is disabled (U80 = 0), it will be "AUTO" mode after power supplied.

4.4 시스템 매개변수 설정

To access and modify system parameters:

  1. 누르다 세트 key to set the temperature. Keeping pressed can fast set.
  2. 누르다 세트 key to set the clock. Keeping pressed can fast set. The setting will be saved 5 seconds later after set.
  3. To enter system parameter set: Press 그리고 keys simultaneously for 3 seconds. The big digits show "P00" for password edit.
  4. 누르다 or key to set password, press 세트 확인합니다.
  5. If the password is wrong, exit. Else enter parameter set status.
  6. 누르다 or to select parameter. Press 세트 to show the value of the parameter.
  7. 누르다 or 값을 설정합니다. 누르다 세트 to return to parameter selection.
  8. 유지하다 세트 pressed for 5 seconds to save the setting, and exit.

The status will exit if there is no key operation for 15 seconds, and the settings will not be saved.

System Parameter Table:

ZL-R200A System Parameter Table
Figure 6: Detailed table of system parameters, their setting functions, ranges, indications, and default values.

시계 설정

  • 누르다 세트 키를 누르면 시간 숫자가 깜박입니다. or 시간을 설정하는 키입니다.
  • 누르다 세트 키를 다시 누르면 분 숫자가 깜박입니다. or 분을 설정하는 키입니다.
  • 누르다 세트 종료 키입니다.

Periods Setting for "SAVE" Mode

  • 유지하다 세트 key depressed for 3 seconds to enter the period setting status.
  • 누르다 세트 key to select the period and on/off. Press or 시간의 가치를 설정합니다.
  • 유지하다 세트 key depressed for 3 seconds to save the settings, and exit.

The status will exit if there is no key operation for 15 seconds, and the settings will not be saved.

5. 유지관리

To ensure the longevity and optimal performance of your ZL-R200A controller, follow these general maintenance guidelines:

  • Keep the display panel clean and free from dust. Use a soft, dry cloth for cleaning.
  • Ensure the controller is installed in a dry, indoor environment to prevent moisture damage.
  • 모든 배선 연결부의 조임 상태와 마모 또는 부식 여부를 정기적으로 점검하십시오.
  • 본 제품을 극한의 온도나 직사광선에 노출시키지 마십시오.
  • If any sensors are damaged or malfunctioning, replace them promptly with compatible parts.

6. 문제 해결

This section provides guidance on common issues you might encounter with your ZL-R200A controller.

6.1 일반적인 문제 및 해결 방법

문제가능한 원인해결책
시스템이 작동하지 않습니다Incorrect U34 setting.Set U34 correctly as per the System Parameter Table.
Real clock loses timePower loss for more than 72 hours.Reset the clock. The real clock can only keep running correctly for 72 hours after power supply loses.
Sensor failure warningSensors not installed correctly or are faulty.Ensure all sensors are installed at correct positions. Check sensor connections and replace faulty sensors if necessary.
설정이 저장되지 않았습니다No key operation for 15 seconds during setting.Ensure to press and hold the SET key for 5 seconds to save settings before the 15-second timeout.
High/Low pressure warning시스템 압력 문제.Consult a qualified technician to diagnose and resolve pressure-related problems in the heat pump system.

7. 사양

매개변수
이름물 가열 컨트롤러
재료인쇄 회로 기판
설정 범위10℃ ~ 70℃
표시 범위-40℃ ~ 130℃
작동 온도0~50℃
보관 온도-10℃ ~ 60℃
주변 습도20-85%RH without dew
전원 공급 장치220VAC ±10%, 50/60Hz
Outputs (Compressor)30A
Outputs (Heaters)8A
Outputs (Others)3A
히스테리시스2~10℃
Water Sensors Calibration-9.9~9.9℃
Heater Energized From-5~25℃
Defrost Starting Time10 분
Defrost Starting Temperature-9~0℃
Defrost Stop Temperature2~30℃
Maximum Defrost Time2-15분
Exhaust Protections Temperature50 ~ 125℃
Display Panel Size86 * 86mm / 3.39 * 3.39인치
메인보드 크기105 * 90 * 35mm / 4.13 * 3.54 * 1.39인치
패키지 무게725g / 1.60파운드

7.1 패키지 내용

  • 1 * Mainboard
  • 1 * Display Panel
  • 4 * Temperature Sensors
ZL-R200A Package Contents
Figure 7: Image showing the ZL-R200A display panel, mainboard, and included accessories like temperature sensors and wiring terminals.

8. 사용자 팁

  • 버전 확인: If you are replacing an older controller, ensure you have the "New version" ZL-R200A for optimal compatibility and features.
  • 전력 손실: Be aware that the internal clock will only retain its setting for up to 72 hours after a power loss. For extended outages, you may need to reset the clock.
  • 센서 배치: Correct placement of all four temperature sensors is crucial for accurate readings and proper system operation.

9. 보증 및 지원

For warranty information, technical support, or service inquiries, please contact your original seller or the product manufacturer. Keep your purchase receipt as proof of purchase.

관련 문서 - ZL-R200A

사전view 에어컨 리모컨 사용 설명서
배터리 설치, 버튼 설명, 작동 모드 등 에어컨 리모컨의 안전하고 올바른 사용을 위한 종합적인 설명서입니다. 타이머, 스윙, ECO, 취침 등 다양한 기능의 사용법을 알아보세요.
사전view 22mm 범용 오토바이 핸들바 LED 조명용 ON/OFF 스위치
내구성이 뛰어나고 방수 기능이 있는 22mm 범용 핸들바 ON/OFF 스위치로 오토바이, ATV, 스쿠터에 사용 가능합니다. 상향등/하향등 제어, 안개등, 경적, 경고등 기능과 호환됩니다. 내한성, 내열성, 내식성을 갖추고 있습니다.
사전view ZL-R200A 히트펌프 온수기 컨트롤러 사용 설명서
LILYTECH ZL-R200A 히트펌프 온수기 컨트롤러의 사용 설명서로, 주요 기능, 기술 사양, 오류 코드, 디스플레이 표시, 주요 작동, 시스템 매개변수 및 제어 기능을 다룹니다.
사전view Términos y Condiciones Promoción Samsung: Cómpralo, Pruébalo y Quédatelo
Samsung Electronics Colombia의 los términos y condiciones de la promoción 'Cómpralo, Pruébalo y Quédatelo'에 대해 알아보세요. Sobre productos, vigencia, y mecánica de participación에 대해 자세히 알아보세요.
사전view 케이블 또는 데이터 케이블 사양 및 지침
ZL-CB 및 XW-CB 시리즈 데이터 및 전원 케이블에 대한 포괄적인 기술 사양 및 안전 지침. 모델 번호, 작동 온도 범위, 입력 전압 등이 포함됩니다.tage, 기기 호환성, 연결 지침 및 안전한 사용을 위한 필수 주의 사항을 제공합니다. 다국어 지원(영어 요약) 기능을 갖추고 있으며, CE, RoHS, UKCA 표준을 준수합니다.
사전view VEVOR Breast Pump Carrying Bags - Models ZL-SND-0623-0628
VEVOR offers durable and reliable breast pump carrying bags in various models (ZL-SND-0623 to ZL-SND-0628). This guide provides product details, safety warnings, and specifications for optimal use.