LPSECURITY PY600ACN

LPSECURITY PY600ACN Sliding Gate Opener Control Board Instruction Manual

Model: PY600ACN (Compatible with SL600, PY600, PY800, SL1500 series)

1. 서론

This manual provides detailed instructions for the installation, operation, and maintenance of the LPSECURITY PY600ACN series control board for sliding gate openers. This PCB circuit board is designed for 220V systems and supports NC (Normally Closed) limit switches, as well as magnetic limit switches. Please read this manual carefully before installation and operation to ensure safe and efficient use.

2. 안전 정보

3. 제품 오버view

3.1개의 구성요소

The LPSECURITY PY600ACN control board is a central component for managing sliding gate operations. It integrates various functionalities for gate control and safety.

맨 위 view of the LPSECURITY PY600ACN control board, showing various terminals, relays, and a DIP switch.
그림 1: 상단 view of the PY600ACN control board, highlighting connection terminals and main components.
각진 view of the LPSECURITY PY600ACN control board, showing the power transformer and terminal blocks.
그림 2: 각도 view of the control board, providing a clearer look at the power input and output sections.

3.2 주요 특징

  • 단일 버튼 제어: A single button can execute all control commands (close, open, stop).
  • Individual Remote Control Deletion: Ability to delete specific remote controls separately.
  • 포괄적인 인터페이스: Supports infrared sensors, solar energy connections, button switches, photocells, and backup batteries.
  • Infrared Detection Connector: Equipped with a dedicated connector for infrared detection.
  • 권tage 옵션: Available in 110V and 220V versions.
  • Limit Switch Compatibility: Supports both mechanical and magnetic limit switches.

4. 사양

기인하다
브랜드 이름LPS 보안
모델 번호PY600ACN (py)
기원중국 본토
인증CE
사용Sliding gate circuit board
권tage220V / 110V
리미트 스위치 유형Magnetic limit switch controller (NC)
애플리케이션Sliding gate door controller
입력Gate photocell lamp
고위험 화학물질없음
스마트 홈 플랫폼없음

5. 설정 및 설치

5.1 Wiring the Control Board

Carefully connect all components to the control board as per the wiring diagram. Ensure correct polarity and secure connections for all wires.

클로즈업 view of the control board terminals with various colored wires connected, indicating power, motor, and sensor inputs.
그림 3: 예ample wiring connections on the control board. Note the green terminal blocks for various inputs and outputs.

5.2 Connecting the Limit Switch

The control board supports both mechanical and magnetic limit switches. Ensure the limit switch is properly connected and functioning. The video demonstrates connecting a magnetic limit switch and verifying its operation.

Video 1: Demonstration of connecting and testing the magnetic limit switch with the control board. Observe the LED indicators for proper function.

Steps for Limit Switch Connection and Test:

  1. Connect the limit switch wires to the designated terminals on the control board.
  2. Ensure the light on the control board corresponding to the limit switch is ON when the switch is activated (e.g., when the magnet is near the sensor).
  3. Test the limit switch by manually moving the magnet past the sensor. The corresponding LED on the board should toggle ON/OFF.

5.3 원격 제어 페어링

To pair a remote control with the control board:

  1. Press the "LEARN" button on the control board (refer to Figure 1 for location). The learning LED should illuminate.
  2. While the learning LED is on, press any button on your remote control. The LED should flash or change state to indicate successful pairing.
  3. Test the remote control by pressing the programmed button. The gate motor should respond (e.g., start moving).

6. 사용 설명서

7. 유지관리

8. 문제 해결

문제가능한 원인해결책
게이트가 리모컨에 반응하지 않습니다.Remote not paired, remote battery low/dead, or incorrect remote.Re-pair the remote control (Section 5.3). Replace remote battery. Ensure you are using the compatible remote control.
Gate does not stop at desired position.Limit switch not properly connected or faulty.Check limit switch wiring and functionality (Section 5.2). Adjust limit switch position if necessary.
Gate motor does not run.No power to the board, motor wiring issue, or safety sensor activated.Check power supply. Verify motor wiring. Ensure photocell or other safety sensors are not obstructed or faulty.

9. 사용자 팁

10. 보증 및 지원

For technical assistance, troubleshooting beyond this manual, or warranty inquiries, please contact LPSECURITY Automation and Security Official Store directly. Keep your purchase records for faster service.

Documents - LPSECURITY – PY600ACN

관련 문서 없음