1. 서론
This manual provides essential information for the installation, operation, and maintenance of the replacement Ignition Coil Module. This module is designed for use with Pramac Lifer 9500 Watts Generators, specifically model S10000 SVEP. Please note that this is a replacement part and not a genuine OEM component. Always compare the appearance and size of this module with your original part before installation to ensure compatibility.
2. 안전 정보
- Always disconnect the generator's spark plug wire and battery (if applicable) before performing any maintenance or installation.
- Ensure the generator is completely cool before handling any components.
- 설치하는 동안 장갑, 눈 보호 장비 등 적절한 개인 보호 장비(PPE)를 착용하세요.
- 어떤 단계에 대해 확신이 없다면 자격을 갖춘 기술자에게 문의하세요.
- 어린이와 애완동물을 작업 구역에서 멀리 두십시오.
3. 패키지 내용
아래 나열된 모든 품목이 패키지에 들어 있는지 확인하세요.
- 1 x Ignition Coil Module (as pictured)

Image 1: The Ignition Coil Module as received in its protective packaging. The module is partially visible, wrapped in bubble wrap inside a white cardboard box.
4. 설정 및 설치
This section outlines the general steps for replacing an existing ignition coil module. Specific procedures may vary slightly depending on your generator's exact configuration. Always refer to your generator's original service manual for detailed instructions.
- 준비:
- Ensure the generator is turned off and has cooled down completely.
- 점화 플러그에서 점화 플러그 와이어를 분리합니다.
- If your generator has a battery, disconnect the negative terminal.
- Locate the existing ignition coil module on your generator. It is typically mounted near the flywheel.
- Removal of Old Module:
- Carefully disconnect any wires or connectors attached to the old ignition coil module.
- Unscrew the mounting bolts or fasteners that secure the old module to the engine block.
- Gently remove the old ignition coil module.
- Installation of New Module:
- Compare the new ignition coil module with the old one to confirm they are visually similar in size and mounting points.
- Position the new ignition coil module in the same location as the old one.
- Secure the module using the original mounting bolts or fasteners. Ensure it is firmly attached.
- Connect all wires and connectors to the new module, ensuring they are properly seated and secure.
- 중요한: Some installations may require minor adjustments for proper fitment. Ensure there is a correct air gap between the coil and the flywheel magnets as specified by your generator's service manual. This often involves using a feeler gauge.
- 마지막 단계:
- 점화 플러그에 점화 플러그 배선을 다시 연결하십시오.
- If disconnected, reconnect the generator's battery.
- Attempt to start the generator to verify proper operation.
5. 작동 원리
The ignition coil module is a critical component of a generator's ignition system. Its primary function is to transform the low voltage from the generator's charging system into the high voltage required to create a spark at the spark plug. This spark ignites the fuel-air mixture in the engine's cylinder, initiating combustion and allowing the generator to run.
A properly functioning ignition coil module ensures consistent and strong spark delivery, which is essential for efficient engine performance, reliable starting, and reduced emissions. This replacement module is designed for high precision, low noise operation, and high temperature resistance, contributing to the overall durability and performance of your generator's ignition system.
6. 유지관리
The ignition coil module itself typically requires minimal maintenance. However, regular inspection of related components can help ensure its longevity and proper function:
- 점화 플러그: Regularly inspect and replace the spark plug according to your generator's maintenance schedule. A worn or fouled spark plug can put undue stress on the ignition coil.
- 배선: Check all wiring connected to the ignition coil module for signs of wear, fraying, or corrosion. Ensure all connections are clean and secure.
- 청결: Keep the area around the ignition coil module clean and free of debris, oil, and dirt, which can interfere with its operation or cause overheating.
- 에어갭: Periodically verify the air gap between the ignition coil and the flywheel magnets, especially if you experience starting issues.
7. 문제 해결
If you encounter issues after installing the new ignition coil module, consider the following common troubleshooting steps:
| 문제 | 가능한 원인 | 해결책 |
|---|---|---|
| Generator does not start or has weak spark. | Incorrect air gap between coil and flywheel. | Adjust the air gap according to generator specifications (typically 0.010-0.014 inches or 0.25-0.35 mm). |
| Generator starts but runs rough or misfires. | 배선 연결부가 헐거워지거나 부식되었습니다. | Check all electrical connections to the module and spark plug. Clean and secure as needed. |
| 점화 플러그에 스파크가 없습니다. | Faulty spark plug or spark plug wire. | Test the spark plug and wire. Replace if defective. |
| Module does not fit correctly. | Incorrect part for your specific generator model. | Double-check the model number and compare the physical appearance of the new module with your original part. Adjustments may be needed for some models. |
If troubleshooting steps do not resolve the issue, it is recommended to consult a professional generator technician.
8. 사양
| 기인하다 | 세부 사항 |
|---|---|
| 제품 유형 | Ignition Coil Module (Replacement Part) |
| 호환성 | Pramac Lifer 9500 Watts Generator model# S10000 SVEP |
| 모델 번호 | nvduq2803-19245 |
| 제조업체 부품 번호 | DUA-PARTS-CSP-PL-29032025-19245 |
| 재료 품질 | High quality, durable |
| 형질 | High precision, low noise, high temperature-resistance |
9. 보증 및 지원