GODIYMODULES QF-RD72

이중 시간 조절 가능 사이클 지연 타이밍 릴레이 모듈 사용자 설명서

Model: QF-RD72

1. 서론

This manual provides detailed instructions for the installation, operation, and maintenance of the GODIYMODULES Dual Time Adjustable Cycle Delay Timing Relay Module. This module is designed for precise control of repetitive power on and off cycles for various equipment and applications, offering high precision, stable, and reliable performance.

2. 제품 오버view

The Dual Time Adjustable Cycle Delay Timing Relay Module is an electronic component designed to manage the on/off cycles of electrical devices. It features an infinite loop mode, allowing the relay to operate continuously according to user-defined run and stop times. This makes it ideal for applications requiring reciprocating strokes or repetitive burn-in tests for products.

GODIYMODULES Dual Time Adjustable Cycle Delay Timing Relay Module

그림 1: 이상view of the Dual Time Adjustable Cycle Delay Timing Relay Module.

The module supports a start/stop function, enabling users to initiate or halt the cycle as needed. It is versatile, suitable for a wide range of voltages from AC 100V to 250V, making it compatible with various power systems including 100V, 110V, 120V, 127V, 220V, 230V, and 240V.

3. 특징

  • Infinite Loop Mode: After initiation, the module enters an infinite loop, with the relay operating according to set run and stop times.
  • 높은 정밀도: Designed for stable and reliable timing performance.
  • 조정 가능한 시간 범위: Both "RUN" time and "STOP" time are widely adjustable, from 0.5 seconds to 1000 minutes.
  • Start/Stop Function: Allows manual control to start or stop the cycling operation.
  • 와이드볼tage 호환성: Operates on AC 100V-250V.
  • 활성 출력: 출력 볼륨tage equals input voltage, with a maximum output current of 10A.
  • Passive Switch Input: Features LED indicators (green for ON, red for OFF) for status.

4. 사양

사양
작업 볼륨tage교류 100V-250V
전력 소비<1.0W
최대 출력 전류<10A
시간 범위0.5초 - 1000분
시간 정확도Max. range value * 0.001 (resolution of 1000)
기대수명100,000번
치수88 x 38 x 22mm (3.46 x 1.49 x 0.86 inches)
장착 구멍 간격83 x 33mm (3.26 x 1.3 인치)
장착 구멍 직경3.2mm(0.12인치)
재료인쇄 회로 기판

5. 설정 및 배선

Proper wiring is essential for the safe and correct operation of the timer module. Refer to the diagram below for terminal connections.

Wiring diagram for the Dual Time Adjustable Cycle Delay Timing Relay Module

Figure 2: Wiring Diagram and Component Labels.

터미널 연결:

  • L (Power L line): Connect to the live (fireWire) input.
  • N (Power N line): Connect to the neutral (zero line) input.
  • Output N: Connect to the neutral line of your load.
  • Output L1: Connect to the live line of your load.
  • LNC (Normally Closed Output): This terminal provides a normally closed live line output. It is generally not required for standard cycling operations.

Note: For most appliances, it is not strictly necessary to distinguish between the L and N lines for the load connection, but always ensure correct power input polarity.

Start/Stop Button (Optional):

  • The module features a passive switch input for a start/stop button (labeled "KEY: RUN/STOP").
  • When the module is powered on, the green LED lights up. Pressing the start button initiates the cycle. Pressing it again will stop the operation, and the red LED will light up.
  • If a start button is not desired, you can connect the two terminals of the "KEY: RUN/STOP" input with a short wire. This will cause the board to cycle infinitely after power on without requiring a button press.

6. 사용 설명서

The module allows for precise adjustment of both the "RUN" time (on-time) and "STOP" time (off-time) using the onboard potentiometers and dip switches.

맨 위 view of the timer module showing RUN TIME and STOP TIME adjustments

그림 3: 상단 view showing time adjustment controls.

Setting Run and Stop Times:

  1. Identify Controls: Locate the "RUN TIME" and "STOP TIME" sections on the PCB. Each section typically has a potentiometer (blue square component) for fine adjustment and a set of dip switches (red components) for selecting the time unit and range.
  2. Select Time Unit/Range: Use the dip switches associated with "RUN TIME" and "STOP TIME" to select the desired time unit (e.g., seconds, minutes) and the overall range (e.g., 0-100, 0-1000). Refer to the markings on the PCB next to the dip switches for specific settings (e.g., "Sec.", "Min.", "0-100", "0-1000").
  3. Adjust Time Value: Rotate the corresponding potentiometer for "RUN TIME" or "STOP TIME" to set the precise duration within the selected range. Turning the potentiometer clockwise typically increases the time, and counter-clockwise decreases it.
  4. 전원 켜기: Once the times are set and wiring is complete, apply power to the module.
  5. 시작 주기: If using the optional start button, press it to begin the infinite cycle. If the "KEY: RUN/STOP" terminals are shorted, the cycle will begin automatically upon power-up.

The relay will then operate, turning on for the set "RUN TIME" and turning off for the set "STOP TIME", repeating this cycle indefinitely until power is removed or the cycle is stopped via the button.

7. 유지관리

The GODIYMODULES Dual Time Adjustable Cycle Delay Timing Relay Module is designed for long-term, reliable operation with minimal maintenance.

  • 청소: Ensure the module is powered off before cleaning. Use a soft, dry cloth to gently wipe away any dust or debris from the PCB and components. Avoid using liquid cleaners or solvents.
  • 환경 조건: Operate the module within its specified temperature and humidity ranges to prevent damage. Avoid exposure to excessive moisture, dust, or corrosive environments.
  • 사이: 모든 배선 연결부를 주기적으로 점검하여 단단히 고정되어 있고 부식이 없는지 확인하십시오. 연결이 헐거우면 작동이 중단되거나 손상될 수 있습니다.

8. 문제 해결

If you encounter issues with your timing relay module, consider the following common troubleshooting steps:

  • 모듈의 전원이 켜지지 않음:
    • 입력 볼륨을 확인하세요tage is within the specified AC 100V-250V range.
    • Check all power connections (L and N) for proper contact and polarity.
    • 전원이 활성화되어 있는지 확인하세요.
  • Relay Not Cycling:
    • If using a start button, ensure it is correctly wired and functioning. Press the button to initiate the cycle.
    • If not using a start button, confirm that the "KEY: RUN/STOP" terminals are properly shorted.
    • Check the "RUN TIME" and "STOP TIME" settings. Ensure they are not set to zero or an extremely short duration that might be unnoticeable.
    • Verify the load is correctly connected to the Output N and Output L1 terminals.
  • 잘못된 타이밍:
    • Recheck the dip switch settings for the time unit and range.
    • Carefully adjust the potentiometers for "RUN TIME" and "STOP TIME" to the desired values.
    • Ensure the time accuracy specification is understood (Max. range value * 0.001).
  • LED 표시기가 작동하지 않음:
    • Green LED should light up when power is applied. If not, check power input.
    • Red LED should light up when the cycle is stopped (if using the button). If not, check button wiring.

이러한 단계를 수행해도 문제가 해결되지 않으면 고객 지원팀에 문의하여 추가 지원을 받으십시오.

9. 보증 및 지원

Information regarding product warranty and specific customer support contacts was not provided in the available product data. For warranty details or technical assistance, please refer to the product packaging or contact the manufacturer, GODIYMODULES, directly through their official channels.

© 2025 GODIYMODULES. 모든 권리 보유.