MSpa P-CA063
MSpa Super Camaro Inflatable Bubble Massage Spa
Model: P-CA063 | User Instruction Manual
1. 안전 정보
Before setting up and using your MSpa, please read all safety instructions carefully. Failure to follow these instructions could result in serious injury or property damage.
1.1. 중요한 안전주의 사항
- Always ensure the spa is placed on a flat, stable, and level surface capable of supporting the weight of the spa filled with water and occupants.
- 이 제품에 연장 코드를 사용하지 마십시오.
- 모든 전기 부품은 물에서 멀리하십시오.
- Supervise children at all times when they are in or near the spa.
- Do not operate the spa if the water temperature exceeds 104°F (40°C).
- 질병이 있는 경우 사용 전에 의사와 상담하십시오.
1.2. PRCD (Portable Residual Current Devices) Test
This product is equipped with a PRCD located at the end of the power cord. The PRCD must be tested before each use to ensure electrical safety. DO NOT use the spa if it cannot pass the PRCD test.
- 전원 코드를 접지된 콘센트에 꽂으세요.
- Press the RESET button on the PRCD. The indicator light should turn on.
- Press the TEST button. The indicator light should turn off.
- Press the RESET button again. The indicator light should turn on.
If the PRCD fails any of these steps, disconnect the power cord and contact a licensed electrician to check the electrical system. Opening the PRCD will void the warranty.
동영상: M Spa Premium Super Camaro Outdoor Bubble Hot Tub Spa. This video demonstrates the setup, operation, and maintenance of the MSpa hot tub, including the PRCD test and inflation process.
2. 설정
2.1. 포장해체 및 구성품 확인
Carefully open the package and remove all components. Refer to the packing list to ensure all parts are present and undamaged.

영상: Key inclusions for the MSpa Super Camaro, showing the spa, inflatable bladder, filter cartridge, spa cover, heat preservation mat, and chemical dispenser.
2.2. Ground Mat Placement
Spread out the square ground mat in your chosen flat area. Ensure the reflective side is facing upwards for optimal heat preservation.
2.3. Spa Inflation
Unfold the deflated spa on the ground mat. Locate the inflation valve and turn the knob anti-clockwise to the 'ON' position. Connect the inflation hose to the valve. Long press the BUBBLE button on the wired controller to start inflation. The inflating process will complete in approximately 120 seconds. Stop inflation when the manometer points out the Yellow section. If the White section is pushed out, the spa is over-inflated; release some air by slightly rotating the valve anti-clockwise until the White section is no longer visible, then tighten the valve.

영상: A hand pressing a button on the MSpa wired controller, which features a digital display and various function buttons.
2.4. 물 채우기
Fill the spa with water until the minimum water line is reached. Do not exceed the maximum water line to prevent pump failure.
2.5. Inflatable Bladder Inflation (for models with covers)
Open the air valve on the inflatable bladder and insert the inflation hose. Press the BUBBLE button to inflate until it is firm but not hard. Disconnect the hose and close the valve. Place the inflated bladder inside the spa cover and zip it up. Cover the spa with the cover and use the buckles to secure it, minimizing heat loss.
3. 운영
3.1. Wired Controller Overview

영상: 상세한 view of the MSpa wired controller, highlighting buttons for heating, bubble massage, UVC sanitizer, filtration, timer, toggle buttons, and ozone generator.
3.2. 가열 기능
Press the HEATER button to turn on the heating function. Use the UP or DOWN buttons to adjust the desired water temperature (up to 104°F / 40°C). The heating rate is approximately 2-3°F per hour.
3.3. 버블 마사지 시스템
Press the BUBBLE button to activate the 138 Air Jets Massage System. This creates thousands of bubbles for relaxation. The bubbling massage function will automatically shut down after every 20 minutes of operation for safety concerns.
3.4. Heating Timer
To set a heating timer, press the TIMER button. Use the UP or DOWN buttons to set the desired time (1-99 hours) for the spa heater to turn on in advance.
3.5. 어린이 안전 잠금 장치
To activate the Child Safety Lock, press and hold the UP and DOWN buttons simultaneously for 3 seconds. This prevents accidental adjustments to the controller. To exit, press and hold the UP and DOWN buttons again for 3 seconds.
3.6. Celsius/Fahrenheit Toggle
Press the C/F button to switch the temperature display between Celsius and Fahrenheit.
3.7. Ozone Function (Elite Collection Only)
If your model is from the Elite Collection, press the OZONE button to turn on/off the Ozone function. 메모: For bathers' safety concern, the ozonator cannot be operated when the Bubble or Jet function is on. Please do not soak in the spa when Ozone is activated. The Ozonator will be off automatically after 2-hour operation.
4. 유지관리
4.1. Filter Cartridge Installation and Replacement
Install the cartridge base to the water inlet inside the spa. Push and fix the filter cartridge to the base. It should always stay in place when the spa is filled with water. 메모: Do not throw away the cartridge base when replacing the filter cartridge. Only change the base when it gets loose after long term using.
Press the FILTER button to turn on/off the filtering function. Please change the filter cartridge if the FILTER button is flashing or in red, indicating it needs replacement.

영상: Diagram illustrating the MSpa Smart Filtration system, which automatically filters water every 8 hours to keep it clean.
4.2. Draining the Spa
To drain the spa, install the drain valve adapter and connect it to a garden hose. Open the drain valve cap at the bottom of the spa to allow water to drain. After draining, press the BUBBLE button to dry out any remaining water in the piping system. Wipe up any remaining water with a clean cloth.
4.3. 보관
Unscrew the air valve cap on the spa pool to deflate. Fold the deflated tub carefully. Put the PRCD aside the knob, in case of defect. The original dust bag is recommended to be used for storage.
5. 문제 해결
If you encounter any issues with your MSpa, please refer to the following common troubleshooting steps:
| 문제 | 가능한 원인 | 해결책 |
|---|---|---|
| 스파가 가열되지 않음 | 히터가 작동하지 않음, 수위가 낮음, 필터가 더럽고, 주변 온도가 너무 낮음. | Ensure HEATER button is on. Check water level. Clean/replace filter. Ensure spa is covered. |
| 거품 없음 | Bubble function not activated, auto-shutdown engaged. | Press BUBBLE button. Wait 20 minutes after auto-shutdown before reactivating. |
| Filter light flashing/red | Filter cartridge is dirty or needs replacement. | 필터 카트리지를 청소하거나 교체하십시오. |
| Spa over-inflated | Too much air in the spa. | Slightly rotate the inflation valve anti-clockwise to release air until the White section of the manometer is no longer visible. |
For more complex issues or error codes displayed on the control panel, please refer to the full MSpa user manual or contact MSpa customer support.
6. 사양

영상: Visual representation of key specifications for the MSpa Camaro Bubble Spa Premium Series, including dimensions, air jets, capacity, and max water temperature.
| 특징 | 세부 사항 |
|---|---|
| 상표 | MSpa |
| 모델명 | M Spa Premium Super Camaro |
| 품목 모델 번호 | P-CA063 |
| 제품 치수 | 80인치 길이 x 80인치 너비 x 28인치 높이 |
| 재료 | 비닐, 폴리염화비닐(PVC) |
| 모양 | Rectangular (Note: Product title says Round, but dimensions suggest square/rectangular. Following provided spec.) |
| 용량 | 245갤런 |
| 제트기 수 | 138 |
| 좌석 수 | 6 |
| 최대 수온 | 화씨 104도(섭씨 40도) |
| 조립이 필요합니다 | 예 |
| 원산지 | 중국 |
7. 보증 및 지원
MSpa is committed to providing high-quality products and customer satisfaction. For warranty information, technical support, or service inquiries, please refer to the official MSpa web사이트를 방문하거나 고객 서비스 부서에 직접 문의하세요.
You can visit the official MSpa store on Amazon for more information: MSpa Store
Ask a question about this manual
Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.