1. 서론
This manual provides detailed instructions for the installation, operation, maintenance, and troubleshooting of the Fydun ZL-7901A Incubator Controller. This device is designed for precise and automatic control of temperature and humidity in various incubation environments, ensuring optimal conditions for successful hatching.
2. 제품 오버view
The Fydun ZL-7901A is a high-precision digital incubator controller capable of managing both temperature and humidity. It features a clear display and intuitive controls for easy programming and monitoring.
주요 특징:
- 정확한 제어: High-accuracy temperature and humidity regulation for stable incubator environments.
- 강력한 간섭 방지 기능: Designed for reliable operation in various conditions.
- High Stability and Accuracy: Ensures consistent performance for critical incubation processes.
- 다양한 용도: Suitable for a variety of eggs including chicken, duck, goose, pigeon, quail, parrot, and peacock.
- 자동 작동: Fully automatic control reduces manual intervention.
구성 요소:

그림 2.1: 앞쪽 view of the Fydun ZL-7901A Incubator Controller, showing the display and control buttons.

그림 2.2: The ZL-7901A controller packaged with its temperature and humidity sensors and connecting cables.

그림 2.3: The ZL-7901A controller shown in an incubator environment, demonstrating its application for egg incubation.
3. 안전 정보
- 설치 및 작동 전에 모든 지침을 주의 깊게 읽으십시오.
- 전원 공급 장치 볼륨을 확인하십시오.tage matches the controller's requirements (100V-240V).
- All wiring should be performed by a qualified professional to prevent electrical hazards.
- 컨트롤러를 물이나 과도한 습기에 노출시키지 마십시오.
- 장치를 가연성 물질 가까이에 두지 마십시오.
- 유지보수 또는 배선 변경 작업을 하기 전에 전원을 차단하십시오.
- 이 장치는 장난감이 아닙니다. 어린이의 손이 닿지 않는 곳에 보관.
4. 설정 및 설치
4.1 컨트롤러 장착
The ZL-7901A controller is designed for panel mounting. Ensure a secure and stable location within your incubator setup.

그림 4.1: 옆 view illustrating the mounting bracket for panel installation.
4.2 배선 연결
Carefully connect the power supply, sensors, and output devices (heater, humidifier, fan, egg turner) to the appropriate terminals on the back of the controller. Refer to the wiring diagram provided with your product for specific connections. Ensure all connections are tight and secure.

그림 4.2: 뒤쪽 view of the controller, showing the terminal blocks for electrical connections.

그림 4.3: 각진 view highlighting the various connection points on the controller's side.
After all connections are made, double-check them for correctness before applying power.
5. 사용 설명서
5.1 전원 켜기/끄기
를 누르세요 전원 버튼 to turn the controller on or off. The display will illuminate upon power-on. The power button is located on the right side of the controller's front panel.
5.2 디스플레이 오버view
The main display shows the current temperature and humidity readings. Additional indicators may show the status of heating, humidifying, and turning functions.
5.3 파라미터 설정
- 를 누르세요 설정 버튼 (gear icon) to enter the parameter setting mode. This button is on the left side of the controller's front panel.
- 사용하세요 Up (위쪽 화살표) 그리고 아래에 (down arrow) buttons to navigate through different parameters (e.g., target temperature, target humidity, egg turning interval). These buttons are on the right side of the controller's front panel.
- 를 누르세요 입력 버튼 (return arrow icon) to select a parameter for editing. This button is on the right side of the controller's front panel.
- 사용하세요 Up 그리고 아래에 값을 조정하는 버튼.
- 를 누르세요 입력 버튼 다시 새 값을 확인합니다.
- Repeat for all desired parameters.
- 설정 모드를 종료하려면 버튼을 누르세요. 설정 버튼 again or waiting for a timeout.
메모: Consult the full product manual (if provided separately) for a complete list of parameters and their functions.
5.4개의 기능 버튼
- 라이트 버튼 (light bulb icon): Controls the internal light of the incubator (if connected). This button is on the left side of the controller's front panel.
- Fn 버튼: Activates special functions or enters advanced settings. Refer to the detailed manual for specific Fn button operations. This button is on the left side of the controller's front panel.
6. 유지관리
6.1 청소
- Ensure the controller is powered off and disconnected from the power source before cleaning.
- Wipe the exterior of the controller with a soft, dry cloth.
- 연마성 세척제, 용제를 사용하거나 제품을 물에 담그지 마십시오.
- Keep the sensor probes clean and free from debris to ensure accurate readings.
6.2 센서 관리
Handle the temperature and humidity sensors with care. Avoid bending or damaging the cables. If readings appear inaccurate, gently clean the sensor tips. Do not attempt to disassemble the sensors.
7. 문제 해결
| 문제 | 가능한 원인 | 해결책 |
|---|---|---|
| 컨트롤러의 전원이 켜지지 않습니다. | 전원 공급 안 됨; 연결 불량; 전원 케이블 불량. | Check power outlet; ensure all connections are secure; test power cable. |
| 온도/습도 측정값이 정확하지 않습니다. | Sensor dirty or damaged; sensor not properly placed; calibration needed. | Clean sensor; reposition sensor away from direct airflow/heat; refer to advanced settings for calibration (if available). |
| Heater/Humidifier not activating. | Output device not connected; setpoint not reached; faulty output device. | Verify wiring connections; check setpoint values; test heater/humidifier independently. |
| 디스플레이에 오류 코드가 표시됩니다. | Sensor fault; internal error. | Note the error code and consult the full product manual or contact support. |
8. 사양
| 특징 | 세부 사항 |
|---|---|
| 모델 | ZL-7901A |
| 상표 | Fydun |
| 입력 Voltage | 100V-240V 교류 |
| 제어 유형 | Fully Automatic Digital Temperature and Humidity Control |
| 정확성 | High precision for both temperature and humidity |
| 애플리케이션 | Incubators for various poultry and bird eggs |
| 설치 | 패널 실장 |
9. 보증 및 지원
Fydun is committed to providing quality products and excellent customer service. If you encounter any issues or have questions regarding your ZL-7901A Incubator Controller, please contact our customer service team.
For support, please refer to the contact information provided with your purchase or visit the official Fydun store on Amazon: Fydun Amazon Store.
Our professional customer service team is ready to assist you promptly.