This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Hayward W3H135FDP H-Series Propane Pool Heater. Please read this manual thoroughly before attempting to install or operate the heater. Keep this manual for future reference.

The Hayward H-Series heater is designed for heating above-ground pools using propane gas. It features a durable cupro nickel heat exchanger, an intuitive electronic control panel, and forced-draft combustion for reliable performance in various weather conditions.

Hayward W3H135FDP H-Series Propane Pool Heater, front view, showing '135,000 BTU GAS HEATER', 'PROPANE', and 'FOR ABOVE GROUND POOLS'.

앞쪽 view of the Hayward W3H135FDP H-Series Propane Pool Heater, highlighting its 135,000 BTU capacity, propane fuel type, and suitability for above-ground pools.

2. 중요한 안전 정보

경고: 부적절한 설치, 조정, 변경, 서비스 또는 유지보수는 재산 피해, 부상 또는 사망을 초래할 수 있습니다. 이 장비를 설치하거나 서비스하기 전에 설치, 작동 및 유지보수 지침을 철저히 읽으십시오.

  • 서비스하기 전에 항상 전원을 분리하십시오.
  • 히터 주변의 적절한 환기를 보장하십시오.
  • 이 기기나 다른 기기 근처에서 가솔린이나 기타 가연성 증기 및 액체를 보관하거나 사용하지 마십시오.
  • 설치 및 서비스는 자격을 갖춘 설치자, 서비스 기관 또는 가스 공급업체를 통해 수행되어야 합니다.
  • 이 히터는 다음을 위해 설계되었습니다. propane gas only. Do not attempt to use natural gas.
  • 히터에서 어린이와 애완동물을 멀리하세요.

3. 패키지 내용

Verify that all components are present before beginning installation. If any parts are missing or damaged, do not proceed with installation and contact Hayward customer support.

  • Hayward W3H135FDP H-Series Propane Pool Heater unit
  • 사용 설명서 (본 문서)
  • Installation hardware (specific items may vary, refer to packing list)

4. 설정 및 설치

Installation must comply with all local codes and ordinances. In the absence of local codes, refer to the National Fuel Gas Code (ANSI Z223.1/NFPA 54) or the Natural Gas and Propane Installation Code (CSA B149.1).

4.1 위치 요구 사항

  • Install the heater outdoors, on a level, non-combustible surface.
  • Maintain adequate clearances from combustible materials and other equipment. Refer to the heater's data plate for specific clearance requirements.
  • Ensure the location allows for proper ventilation and drainage.
  • Avoid locations where the heater may be exposed to excessive wind or spray from the pool.

4.2 배관 연결

Connect the heater to your pool's filtration system. The heater should be installed after the filter and before any chemical feeders.

  • 누수를 방지하려면 적절한 배관 부속품과 밀봉재를 사용하십시오.
  • Ensure proper water flow through the heater. Insufficient flow can cause damage.
옆 view of the Hayward W3H135FDP H-Series Pool Heater, showing plumbing connections and internal components, with text indicating 'FASTER HEATING', '82% THERMAL EFFICIENCY', and 'FORCED-DRAFT COMBUSTION'.

옆 view of the heater, illustrating the plumbing inlet/outlet and the forced-draft combustion system.

4.3 Gas Connections (Propane Only)

중요한: This heater is factory-set for propane gas. Do not attempt to convert it to natural gas. Gas connections must be made by a qualified professional.

  • Connect the propane supply line to the heater's gas inlet.
  • Ensure all gas connections are tight and leak-free. Use a leak detection solution to check for leaks.
  • Install a manual gas shut-off valve upstream of the heater.

4.4 전기 연결

Electrical wiring must be performed by a qualified electrician in accordance with all local codes and the National Electrical Code (NFPA 70).

  • 히터가 올바르게 접지되었는지 확인하세요.
  • 히터를 적절한 과전류 보호 장치가 있는 전용 회로에 연결하십시오.

5. 사용 설명서

5.1 초기 시작

  1. Ensure the pool pump is running and there is adequate water flow through the heater.
  2. Open the manual gas shut-off valve to supply propane to the heater.
  3. Turn on the electrical power to the heater.
  4. The electronic control panel will illuminate.

5.2 원하는 온도 설정

Use the intuitive electronic control panel to set your desired pool temperature.

  1. Press the "Mode" button to select the pool heating function.
  2. Use the up/down arrow buttons to adjust the target temperature.
  3. 히터는 자동으로 점화되어 설정된 온도까지 물을 가열하기 시작합니다.
Hayward W3H135FDP H-Series Pool Heater, showing the electronic control panel with temperature display and control buttons.

The electronic control panel for setting and monitoring pool temperature.

5.3 히터 끄기

  1. To temporarily stop heating, turn off the heater via the control panel.
  2. For extended shutdown or servicing, close the manual gas shut-off valve and turn off the electrical power to the heater.

6. 유지관리

Regular maintenance ensures optimal performance and longevity of your Hayward H-Series heater. Always disconnect power and gas supply before performing any maintenance.

6.1 정기 점검

  • 월간 간행물: Inspect the area around the heater for debris, obstructions, or signs of leaks.
  • 계절별로: Check the heat exchanger for scale buildup or corrosion. If necessary, clean according to manufacturer guidelines or consult a qualified service technician.
  • Ensure proper water chemistry in your pool to prevent damage to the heater's components.

6.2 방한처리

In areas subject to freezing temperatures, proper winterization is crucial to prevent damage.

  1. Turn off the heater and disconnect both electrical power and gas supply.
  2. Drain all water from the heater's plumbing and heat exchanger. Use a shop vacuum or air compressor to ensure all water is removed.
  3. Store the heater in a dry, protected area if possible, or cover it with a weather-resistant cover.

7. 문제 해결

고객 지원에 문의하기 전에 다시 문의하세요.view 다음은 일반적인 문제와 해결책입니다.

문제가능한 원인해결책
히터가 점화되지 않습니다.No gas supply, low water flow, electrical issue, faulty igniter.Check gas valve, ensure pump is running, verify power, consult service technician.
히터가 자주 켜지고 꺼집니다.물 흐름 부족, 필터 오염, 시스템 내 공기 유입, 히터 용량 과다.Check pump and filter, bleed air from system, consult pool professional.
Error code displayed on panel.특정 시스템 오류.Refer to the heater's specific error code list in the full manual or contact support.
온수가 나오지 않습니다.Incorrect temperature setting, low gas pressure, heat exchanger issue.Verify temperature setting, check gas supply, contact service technician.

If troubleshooting steps do not resolve the issue, contact Hayward customer support or a qualified service professional.

8. 사양

  • 모델: W3H135FDP
  • 연료 유형: 프로판 가스
  • BTU 입력: 135,000 BTU/시간
  • 열 효율: 82%
  • 열교환 기: Cupro Nickel
  • 치수(길이 x 너비 x 높이): 약 30.3 x 21.4 x 22.6cm(77 x 54.4 x 57.4인치)
  • 품목 무게: 약 117.5파운드(53.3kg)
  • 전기 요구 사항: 특정 볼륨에 대한 제품 라벨을 참조하세요.tage와 amp분노.
  • NOx 배출: Low NOx (meets clean air quality standards)
Hayward W3H135FDP H-Series Pool Heater, front view with detailed dimensions: Length 30.3 inches, Width 21.4 inches, Height 22.6 inches, and Weight 117.5 lbs.

Product dimensions and weight for the Hayward W3H135FDP H-Series Pool Heater.

네 views of the Hayward W3H135FDP H-Series Pool Heater: Right, Front, Left, and Rear, showing the overall design and connection points.

다양한 views of the Hayward W3H135FDP H-Series Pool Heater, illustrating its design from different angles.

9. 보증 및 지원

Hayward provides a limited warranty for its products. For specific warranty terms and conditions, please refer to the warranty card included with your product or visit the official Hayward web대지.

For technical assistance, parts, or service, please contact Hayward customer support:

  • Web대지: www.hayward.com
  • 핸드폰: 헤이워드를 참조하십시오. web지역 연락처 사이트.

When contacting support, please have your model number (W3H135FDP) and serial number ready.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.