1. 서론
This manual provides comprehensive instructions for the safe and proper installation and use of the RACO 926 Ceiling Fan Box with Brace. This product is designed for new work applications to securely support ceiling fans and lighting fixtures weighing up to 90 pounds.
2. 안전 정보
경고: Risk of electric shock. Always disconnect power at the circuit breaker or fuse box before installation, servicing, or removing any fixture. Failure to do so can result in serious injury or death.
- Installation must be performed by a qualified electrician or in accordance with all local and national electrical codes.
- 전기 공급량을 확인하십시오.tage is correct for the fixture being installed.
- Do not exceed the maximum weight capacity of 90 pounds for supported fixtures.
- 설치하는 동안 적절한 개인 보호 장비(PPE)를 착용하세요.
- 설치하기 전에 제품에 손상이 있는지 확인하십시오. 손상된 부품은 설치하지 마십시오.
3. 제품 오버view
The RACO 926 is a 1-1/2-inch deep octagon electrical box specifically designed for new construction. It features an integrated brace for secure mounting between joists, providing robust support for ceiling fans and heavy lighting fixtures. The box is constructed from copper material with a painted finish.

Figure 1: RACO 926 Ceiling Fan Box with Brace. This image displays the gray octagon electrical box securely mounted to an adjustable black metal brace, ready for installation between ceiling joists.
4. 설정 및 설치
This section details the steps for installing the RACO 926 Ceiling Fan Box in new construction.
4.1 필요한 도구
- 드라이버 (십자 드라이버 및/또는 일자 드라이버)
- 와이어 스트리퍼/커터
- 줄자
- 연필
- 드릴 (선택 사항, 파일럿 구멍용)
- 보안경 및 장갑
4.2 설치 단계
- 설치 영역 준비: Ensure power is off at the main circuit breaker. Identify the desired location for the ceiling fan or fixture. This box is designed for installation between ceiling joists (typically 16 or 24 inches on center).
- Adjust the Brace: The brace is adjustable. Extend or retract the brace to fit snugly between the two adjacent ceiling joists. The brace should be positioned so the octagon box is centered where the fixture will be mounted.
- 버팀대 고정: Position the brace against the bottom edge of the ceiling joists. Use appropriate screws (not included, typically wood screws) to firmly attach the ends of the brace to the joists. Ensure the brace is level and securely fastened to prevent movement.
- 경로 배선: Bring the electrical supply wires into the octagon box through one of the knockouts. Use appropriate cable connectors (not included) to secure the wires and protect them from sharp edges.
- Prepare for Fixture Mounting: Once the box and brace are securely installed and wiring is routed, the box is ready for the attachment of a ceiling fan or lighting fixture. Follow the specific instructions provided with your fan or fixture for wiring and mounting.
5. 기능 및 사용
The RACO 926 Ceiling Fan Box serves as a secure mounting point and enclosure for electrical connections for ceiling fans and lighting fixtures. Its robust design and brace ensure stable support for fixtures up to 90 pounds, preventing sagging or detachment. Once installed and wired correctly, it provides a safe and compliant housing for electrical splices and fixture attachment.
6. 유지관리
The RACO 926 Ceiling Fan Box requires minimal maintenance once properly installed. Periodically, during any fixture replacement or inspection, ensure the following:
- 시각적 검사: Check for any signs of corrosion, damage, or loose connections within the box.
- 안전한 장착: Verify that the brace remains firmly attached to the ceiling joists and the box is securely fastened to the brace.
- 배선 무결성: Ensure all wire connections are tight and insulation is intact.
Always disconnect power before performing any inspection or maintenance inside the electrical box.
7. 문제 해결
If a ceiling fan or fixture connected to the RACO 926 box is not functioning correctly, consider the following troubleshooting steps:
- 전원 공급 없음:
- Check the circuit breaker or fuse for the affected circuit. Reset if tripped.
- Verify that all wire connections inside the RACO 926 box are secure and correctly wired according to the fixture's instructions and local codes.
- Test the power supply wires with a voltage tester to ensure power is present at the box.
- Fixture Loose or Wobbling:
- Ensure the fixture mounting screws are tight and properly engaged with the RACO 926 box.
- Inspect the brace to ensure it is still securely fastened to the ceiling joists and has not shifted.
If issues persist after these steps, consult a qualified electrician.
8. 사양
| 모델 번호 | 926 |
| 상표 | 라코 |
| 상자 유형 | Octagon, 1-1/2-inch Deep |
| 애플리케이션 | New Work, Ceiling Fan/Fixture Support |
| 재료 | 구리 |
| 마무리 유형 | 그린 |
| 색상 | Gray, Black (Brace) |
| 용량 | Up to 90 Pounds (Fixture Support) |
| 사양 충족 | UL |
| ASIN | B08X7FPT63 |
| GTIN/UPC | 370377562181 |
9. 보증 및 지원
For information regarding product warranty, technical support, or replacement parts, please contact RACO customer service directly. Refer to the official RACO web최신 연락처 정보는 해당 사이트나 제품 포장에서 확인하세요.
RACO Official Web대지: https://www.hubbell.com/raco/en