U.S. Solid USS-DBS3-1

U.S. Solid 100g 0.001g Digital Analytical Balance Precision Scale

Model: USS-DBS3-1

소개

This manual provides essential information for the proper operation and maintenance of your U.S. Solid Digital Analytical Balance. Please read this manual thoroughly before using the scale to ensure accurate measurements and prolong the life of the instrument. This precision scale is designed for laboratory and industrial applications requiring high accuracy measurements up to 100 grams with 0.001g readability.

안전 정보

  • Always operate the scale on a stable, level, and vibration-free surface.
  • Avoid placing the scale near strong electromagnetic fields, heat sources, or direct sunlight.
  • 저울의 최대 용량인 100g을 초과하여 과부하를 주지 마십시오.
  • Keep the scale clean and free from dust, liquids, and corrosive substances.
  • 손상을 방지하기 위해 방풍 덮개와 계량 접시를 조심스럽게 다루십시오.
  • Ensure the power adapter is correctly connected and use only the provided adapter.

패키지 내용

포장을 풀 때 모든 품목이 들어 있고 상태가 양호한지 확인하세요.

  • U.S. Solid Digital Analytical Balance
  • Stainless Steel Weighing Pan
  • Draft Shield (Windshield)
  • AC/DC 전원 어댑터
  • Calibration Weight (typically 100g)
  • 사용 설명서 (본 문서)

제품 끝view

Familiarize yourself with the main components and controls of the analytical balance.

맨 위 view of the U.S. Solid Digital Analytical Balance showing the control panel and draft shield.
그림 1: 상단 View of Analytical Balance. 이 이미지는 상단을 표시합니다. view of the U.S. Solid Digital Analytical Balance, highlighting the control panel with its buttons and the transparent draft shield covering the weighing pan.
Diagram showing the control panel buttons: ON/OFF, UNIT, PCS, CAL, TARE/ZERO, and the Backlit LED Display, Draft Shield, SS Pan, and AC & DC Power Supply.
Figure 2: Control Panel and Key Components. This diagram labels the main buttons on the control panel including ON/OFF, UNIT, PCS (Counting Mode), CAL (Calibrate), and TARE/ZERO. It also points out the Backlit LED Display, Draft Shield, Stainless Steel (SS) Pan, and the AC & DC Power Supply connection.

주요 구성 요소:

  • 저울 접시: 무게를 <binary data, 8 bytes>할 물품을 올려놓는 스테인리스 스틸 플랫폼.
  • 드래프트 쉴드: Transparent enclosure to protect the weighing pan from air currents, ensuring stable and accurate readings.
  • LCD 디스플레이: Backlit screen showing weight readings, units, and other operational information.
  • 제어 버튼:
    • 켜기/끄기: 저울의 전원을 켜거나 끕니다.
    • 단위: Cycles through available weighing units (g, ct, oz, lb, etc.).
    • PCS (Counting Mode): 개수 계산 기능을 활성화합니다.
    • CAL (Calibrate): 교정 프로세스를 시작합니다.
    • 용기/영점: Resets the display to zero, or tares the weight of a container.
  • 레벨링 버블: Indicates if the scale is perfectly level.
  • 조절 가능한 다리: Used to level the scale.

설정

1. 배치 및 수평 맞추기

For optimal accuracy, place the analytical balance on a firm, stable, and level surface, free from vibrations, drafts, and direct heat.

옆 view of the U.S. Solid Digital Analytical Balance showing the leveling bubble.
Figure 3: Leveling Bubble. This image shows a close-up of the leveling bubble on the side of the scale, which helps ensure the device is perfectly horizontal for accurate measurements.
Diagram illustrating horizontal adjustment using leveling feet and the importance of environmental stability.
Figure 4: Horizontal Adjustment and Environmental Stability. This diagram illustrates how to adjust the leveling feet until the bubble is centered for proper horizontal adjustment. It also emphasizes the need for a stable, vibration-free environment, away from air currents and temperature changes, to maintain accuracy.
  1. Place the scale on a sturdy workbench or table.
  2. Adjust the four adjustable feet located at the bottom of the scale until the bubble in the leveling indicator is perfectly centered. This ensures the weighing mechanism is horizontal.

2. 전원 연결

Connect the provided AC/DC power adapter to the power input port on the scale and then plug it into a suitable electrical outlet.

3. Warm-up Time

After connecting power, allow the balance to warm up for at least 30 minutes before use. This stabilizes the internal components and ensures accurate measurements. For best results, keep the scale powered on during periods of frequent use.

작동 지침

1. 전원 켜기/끄기

  • 를 누르세요 켜짐/꺼짐 button to turn the scale on. The display will show a self-test sequence and then settle at 0.000g.
  • 를 누르고 계세요 켜짐/꺼짐 저울을 끄는 버튼입니다.

2. 교정

Calibration is crucial for maintaining accuracy. It is recommended to calibrate the scale before first use, after moving it, or if you suspect inaccurate readings.

Diagram showing the calibration process with the CAL button and placement of calibration weight.
Figure 5: Calibration Process. This diagram illustrates the steps for calibration, including pressing the CAL button and placing the provided calibration weight on the weighing pan. The display will guide the user through the process.
  1. 계량 접시가 비어 있고 방풍 덮개가 닫혀 있는지 확인하십시오.
  2. 를 누르세요 button. The display will show "CAL" followed by the required calibration weight (e.g., "100.000g").
  3. Carefully place the specified calibration weight (e.g., 100g) onto the center of the weighing pan.
  4. Wait for the display to stabilize and show "PASS" or return to 0.000g, indicating successful calibration.
  5. Remove the calibration weight. The scale is now ready for use.

3. 무게 측정

  1. Ensure the scale is powered on and displays 0.000g. If not, press 용기/영점.
  2. 무게를 <binary data, 8 bytes>할 물건을 저울 접시 중앙에 조심스럽게 올려놓으십시오.
  3. Close the draft shield to prevent air currents from affecting the reading.
  4. LCD 화면에 표시된 안정 중량을 읽으십시오.
  5. 냄비에서 내용물을 꺼내세요.

4. Tare 기능

용기 무게를 제외하는 용기 무게 제외 기능을 사용하면 내용물의 순중량만 측정할 수 있습니다.

  1. Place an empty container on the weighing pan. The display will show its weight.
  2. 를 누르세요 용기/영점 버튼을 누르세요. 디스플레이가 0.000g으로 재설정됩니다.
  3. Add the substance to be weighed into the container. The display will now show only the weight of the substance.
  4. To clear the tare, remove the container from the pan and press 용기/영점 다시.

5. 단위 환산

The scale supports multiple weighing units.

Diagram showing various measuring units available on the scale: g, ct, oz, ozt, lb, N, T, GN, dr, tlT, T/A/R.
Figure 6: Measuring Units. This diagram illustrates the different measuring units supported by the scale, including grams (g), carats (ct), ounces (oz), troy ounces (ozt), pounds (lb), Newtons (N), Tael (T), Grains (GN), Dram (dr), Tola (tlT), and T/A/R.
  • 를 누르세요 단위 button to cycle through the available weighing units (e.g., grams (g), carats (ct), ounces (oz), pounds (lb)).
  • The currently selected unit will be displayed on the LCD.

6. Piece Counting (PCS)

This function allows you to count a large number of identical items by weighing a samp르.

Diagram showing the piece counting function with sample sizes: 10, 20, 50, 100, 150, 200, 250, 500.
Figure 7: Piece Counting Sample Sizes. This diagram illustrates the various sample sizes that can be used for the piece counting function, including 10, 20, 50, 100, 150, 200, 250, and 500 pieces.
  1. 측정 접시에 정해진 수량(예: 10개, 20개, 50개, 100개)의 물건을 올려놓으세요.
  2. 를 누르세요 PC(전자제품) button. The display will show "PCS" and a number (e.g., "PCS 10").
  3. 를 누르세요 단위 s를 선택하려면 버튼을 누르세요ample size that matches the number of items you placed on the pan.
  4. 누르다 PC(전자제품) 다시 한번 s를 확인하기 위해ample size. The display will now show the total count of items.
  5. You can now add more items, and the scale will display the total count.
  6. 계수 모드를 종료하려면 버튼을 누르십시오. PC(전자제품) 버튼을 다시 누르세요.

유지

1. 청소

  • 청소하기 전에 항상 전원 어댑터를 분리하십시오.
  • Wipe the scale's exterior with a soft, damp 천을 사용하십시오. 연마성 세척제, 용제를 사용하거나 스케일을 물에 담그지 마십시오.
  • The stainless steel weighing pan can be removed and cleaned separately with mild soap and water. Ensure it is completely dry before placing it back on the scale.
  • Clean the draft shield with a soft cloth to maintain visibility.

2. 보관

  • When not in use for extended periods, store the scale in a dry, dust-free environment at room temperature.
  • Keep the draft shield in place to protect the weighing mechanism.

문제 해결

문제가능한 원인해결책
디스플레이에 "Err" 또는 불안정한 판독값이 표시됩니다.Overload, unstable surface, strong air currents, electromagnetic interference, or internal error.
  • Ensure item weight is within capacity (max 100g).
  • Place scale on a stable, level surface.
  • Close the draft shield.
  • Move scale away from electronic devices.
  • 저울을 다시 보정하십시오.
  • Restart the scale.
부정확한 판독값.Not calibrated, unstable environment, insufficient warm-up time, or dirty pan.
  • 캘리브레이션을 수행합니다.
  • Ensure scale is level and on a stable surface.
  • Allow 30 minutes warm-up time.
  • Clean the weighing pan.
  • Ensure no air currents are affecting the scale.
저울이 켜지지 않습니다.No power, faulty adapter, or internal issue.
  • 전원 어댑터 연결과 벽면 콘센트를 확인하세요.
  • 전원 버튼을 확실하게 눌렀는지 확인하세요.
  • If using batteries (if applicable), check battery level.
Tare function not working.잘못된 작동.
  • Ensure the container is placed on the pan before pressing TARE/ZERO.
  • Remove the container and press TARE/ZERO to clear previous tare.

명세서

특징세부 사항
상표미국 솔리드
모델 번호USS-DBS3-1
용량100g
Readability / Accuracy0.001g / 1 mg
디스플레이 유형백라이트가있는 LCD
무게 단위g, ct, oz, lb, N, T, GN, dr, tlT, T/A/R
전원 공급 장치AC/DC Adapter (100-240V)
저울판 재질스테인리스 스틸
제품 치수13.78 x 9.45 x 4.92 인치
품목 무게4.39파운드

보증 및 지원

U.S. Solid products are designed for reliability and performance. For warranty information, technical support, or service inquiries, please refer to the official U.S. Solid web사이트를 방문하거나 고객 서비스에 직접 문의하세요. 보증 청구를 위해 구매 영수증을 보관하세요.

U.S. Solid Customer Service: 방문해주세요 www.ussolid.com 연락처 정보와 지원 리소스를 확인하세요.

© 2023 U.S. Solid. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.